Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6GK5738-1GY00-0AA0

6GK5738-1GY00-0AB0

Transmission rate

Transfer rate

  • with WLAN maximum

300Mbit/s

300Mbit/s

  • for Industrial Ethernet

10,100Mbit/s

10,100Mbit/s

Transfer rate for Industrial Ethernet

  • minimum

10Mbit/s

10Mbit/s

  • maximum

100Mbit/s

100Mbit/s

Interfaces

Number of electrical connections

  • for network components or terminal equipment

2

2

  • for power supply

1

1

  • for redundant voltage supply

1

1

Type of electrical connection

  • for network components or terminal equipment

M12 interface (4-pole, D-coded), PoE

M12 interface (4-pole, D-coded), PoE

  • for power supply

M12 interface (4-pole, A-coded)

M12 interface (4-pole, A-coded)

design of the removable storage

  • C-PLUG

Yes

Yes

  • KEY-PLUG

Yes

Yes

Interfaces wireless

Number of radio cards permanently installed

1

1

Transmission mode for multiple input multiple output (MIMO)

2x2

2x2

Number of spatial streams

2

2

Number of electrical connections for external antenna(s)

2

2

Type of electrical connection for external antenna(s)

N-Connect (socket)

N-Connect (socket)

Product feature external antenna can be mounted directly on device

Yes

Yes

Supply voltage, current consumption, power loss

Type of voltage of the supply voltage

DC

DC

Supply voltage 1

  • from M12 Power Connector (A-coded) for redundant power supply

16.8V

16.8V

Supply voltage 2

  • from M12 Power Connector (A-coded) for redundant power supply

31.2V

31.2V

Supply voltage

  • from Power-over-Ethernet acc. to IEEE802.3at for type 1 and IEEE802.3af

48V

48V

Consumed current

  • at DC at 24 V typical

0.25A

0.25A

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

0.125A

0.125A

Power loss [W]

  • at DC at 24 V typical

6W

6W

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

6W

6W

Permitted ambient conditions

Ambient temperature

  • during operation

-20...+60C

-20...+60C

  • during storage

-40...+85C

-40...+85C

  • during transport

-40...+85C

-40...+85C

Relative humidity at 25 C without condensation during operation maximum

95%

95%

Protection class IP

IP65

IP65

Design, dimensions and weight

Width

140mm

140mm

Height

160mm

160mm

Depth

45mm

45mm

Width of the enclosure without antenna

140mm

140mm

Height of the enclosure without antenna

149mm

149mm

Depth of the enclosure without antenna

45mm

45mm

Net weight

0.95kg

0.95kg

Mounting type

  • S7-300 rail mounting

No

No

  • S7-1500 rail mounting

No

No

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

Yes

Yes

Wireless frequencies

Operating frequency

  • for WLAN in 2.4 GHz frequency band

2.41...2.48GHz

2.41...2.48GHz

  • for WLAN in 5 GHz frequency band

4.9...5.8GHz

4.9...5.8GHz

Product properties, functions, components general

Product function Access Point Mode

No

No

Product function Client Mode

Yes

Yes

Product function

  • iPCF client

Yes; Only in combination with the 'KEY-PLUG W780 iFeatures' or 'KEY-PLUG W740 iFeatures'

Yes; Only in combination with the 'KEY-PLUG W780 iFeatures' or 'KEY-PLUG W740 iFeatures'

  • iPCF-MC client

Yes; Only in combination with 'KEY-PLUG W780 iFeatures' or 'KEY-PLUG W740 iFeatures'

Yes; Only in combination with 'KEY-PLUG W780 iFeatures' or 'KEY-PLUG W740 iFeatures'

Number of iPCF-capable radio modules

1

1

Product function iREF

No

No

Product function iPRP

Yes; In combination with the 'KEY-PLUG W780 iFeatures' only

Yes; In combination with the 'KEY-PLUG W780 iFeatures' only

Product functions management, configuration

Number of manageable IP addresses in client

8

8

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • configuration with STEP 7 in the TIA Portal

Yes

Yes

  • operation with IWLAN controller

No

No

  • operation with Enterasys WLAN controller

No

No

  • WDS

No

No

Protocol is supported

  • Address Resolution Protocol (ARP)

Yes

Yes

  • ICMP

Yes

Yes

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

No

No

Identification & maintenance function

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 higher-level designation/location designation

Yes

Yes

Product functions Diagnosis

Product function

  • PROFINET IO diagnosis

Yes

Yes

  • Link Check

No

No

  • connection monitoring IP-Alive

No

No

  • SysLog

Yes

Yes

Protocol is supported

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

Product functions VLAN

Product function

  • function VLAN with IWLAN

No

No

Product functions DHCP

Product function

  • DHCP client

Yes

Yes

  • in Client Mode DHCP server via LAN

Yes

Yes

  • DHCP Option 82

Yes

Yes

Product functions Redundancy

Protocol is supported

  • STP/RSTP

Yes

Yes

  • MSTP

Yes

Yes

  • RSTP

Yes

Yes

Product functions Security

Product function

  • ACL - MAC-based

Yes

Yes

  • Management security, ACL-IP based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • NAT/NAPT

Yes

Yes

  • access protection according to IEEE802.11i

Yes

Yes

  • WPA/WPA2

Yes

Yes

  • TKIP/AES

Yes

Yes

Protocol is supported

  • SSH

Yes

Yes

  • RADIUS

Yes

Yes

Product functions Time

Protocol is supported

  • NTP

Yes

Yes

  • SNTP

Yes

Yes

  • SIMATIC Time

Yes

Yes

Standards, specifications, approvals

Standard

  • for FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety from CSA and UL

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

  • for hazardous zone from CSA and UL

ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC

ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC

Certificate of suitability

  • EC declaration of conformity

Yes

Yes

  • CE marking

Yes

Yes

  • C-Tick

Yes

Yes

  • E1 approval

No

No

  • Railway application in accordance with EN 50155

No

No

  • Fire protection in accordance with EN 45545-2

Yes

Yes

  • NEMA TS2

No

No

  • IEC 61375

No

No

  • IEC 61850-3

No

No

  • NEMA4X

No

No

  • Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

No

No

  • Power-over-Ethernet according to IEEE802.3at for type 2

No

No

Standard for wireless communication

  • IEEE 802.11a

Yes

Yes

  • IEEE 802.11b

Yes

Yes

  • IEEE 802.11e

Yes

Yes

  • IEEE 802.11g

Yes

Yes

  • IEEE 802.11h

Yes

Yes

  • IEEE 802.11i

Yes

Yes

  • IEEE 802.11n

Yes

Yes

Wireless approval

You will find the current list of countries at: www.siemens.de/funkzulassungen

You will find the current list of countries at: www.siemens.de/funkzulassungen

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

No

No

  • Bureau Veritas (BV)

No

No

  • DNV GL

No

No

  • Lloyds Register of Shipping (LRS)

No

No

  • Nippon Kaiji Kyokai (NK)

No

No

  • Polski Rejestr Statkow (PRS)

No

No

  • Royal Institution of Naval Architects (RINA)

No

No



















  © " " 2007-2022