Article number

6AG2212-1AE40-1XB0

SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL

General information

 

Product type designation

CPU 1212C DC/DC/DC

Supply voltage

 

Rated value (DC)

  • â—� 24 V DC

Yes

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

Reverse polarity protection

Yes

Load voltage L+

 

  • â—� Rated value (DC)

24 V

  • â—� permissible range, lower limit (DC)

20.4 V

  • â—� permissible range, upper limit (DC)

28.8 V

Input current

 

Current consumption (rated value)

400 mA; Typical

Inrush current, max.

12 A; at 28.8 V DC

Output current

 

for backplane bus (5 V DC), max.

890 mA; Max. 5 V DC for SM and CM

Encoder supply

 

24 V encoder supply

 

  • â—� 24 V

Permissible range: 20.4V to 28.8V

Power loss

 

Power loss, typ.

9 W

Memory

 

Work memory

 

  • â—� integrated

50 kbyte

  • â—� expandable

No

Load memory

 

  • â—� integrated

1 Mbyte

  • â—� Plug-in (SIMATIC Memory Card), max.

2 Gbyte; with SIMATIC memory card

Backup

 

  • â—� present

Yes; maintenance-free

  • â—� without battery

Yes

CPU processing times

 

for bit operations, typ.

0.085 µs; / Operation

for word operations, typ.

1.7 µs; / Operation

for floating point arithmetic, typ.

2.3 µs; / Operation

CPU-blocks

 

Number of blocks (total)

DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used

OB

 

  • â—� Number, max.

Limited only by RAM for code

Data areas and their retentivity

 

Retentive data area (incl. timers, counters, flags), max.

10 kbyte

Flag

 

  • â—� Number, max.

4 kbyte; Size of bit memory address area

Address area

 

I/O address area

 

  • â—� Inputs

1 024 byte

  • â—� Outputs

1 024 byte

Process image

 

  • â—� Inputs, adjustable

1 kbyte

  • â—� Outputs, adjustable

1 kbyte

Hardware configuration

 

Number of modules per system, max.

3 comm. modules, 1 signal board, 2 signal modules

Time of day

 

Clock

 

  • â—� Hardware clock (real-time)

Yes

  • â—� Backup time

480 h; Typical

  • â—� Deviation per day, max.

60 s/month at 25 °C

Digital inputs

 

Number of digital inputs

8; Integrated

  • â—� of which inputs usable for technological functions

6; HSC (High Speed Counting)

Source/sink input

Yes

Number of simultaneously controllable inputs

 

all mounting positions

 

  • — up to 40 °C, max.

8

Input voltage

 

  • â—� Rated value (DC)

24 V

  • â—� for signal "0"

5 V DC at 1 mA

  • â—� for signal "1"

15 V DC at 2.5 mA

Input current

 

  • â—� for signal "1", typ.

1 mA

Input delay (for rated value of input voltage)

 

for standard inputs

 

  • — parameterizable

0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms

  • — at "0" to "1", min.

0.1 µs

  • — at "0" to "1", max.

20 ms

for interrupt inputs

 

  • — parameterizable

Yes

for counter/technological functions

 

  • — parameterizable

Single phase: 3 @ 100 kHz & 1 @ 30 kHz, differential: 3 @ 80 kHz & 1 @ 30 kHz

Cable length

 

  • â—� shielded, max.

500 m; 50 m for technological functions

  • â—� unshielded, max.

300 m; For technological functions: No

Digital outputs

 

Number of digital outputs

6

  • â—� of which high-speed outputs

4; 100 kHz Pulse Train Output

Limitation of inductive shutdown voltage to

L+ (-48 V)

Switching capacity of the outputs

 

  • â—� with resistive load, max.

0.5 A

  • â—� on lamp load, max.

5 W

Output voltage

 

  • â—� for signal "0", max.

0.1 V; with 10 kOhm load

  • â—� for signal "1", min.

20 V

Output current

 

  • â—� for signal "1" rated value

0.5 A

  • â—� for signal "0" residual current, max.

0.1 mA

Output delay with resistive load

 

  • â—� "0" to "1", max.

1 µs

  • â—� "1" to "0", max.

3 µs

Switching frequency

 

  • â—� of the pulse outputs, with resistive load, max.

100 kHz

Cable length

 

  • â—� shielded, max.

500 m

  • â—� unshielded, max.

150 m

Analog inputs

 

Number of analog inputs

2

Input ranges

 

  • â—� Voltage

Yes

Input ranges (rated values), voltages

 

  • â—� 0 to +10 V

Yes

  • â—� Input resistance (0 to 10 V)

≥100k ohms

Cable length

 

  • â—� shielded, max.

100 m; twisted and shielded

Analog outputs

 

Number of analog outputs

0

Analog value generation for the inputs

 

Integration and conversion time/resolution per channel

 

  • â—� Resolution with overrange (bit including sign), max.

10 bit

  • â—� Integration time, parameterizable

Yes

  • â—� Conversion time (per channel)

625 µs

Encoder

 

Connectable encoders

 

  • â—� 2-wire sensor

Yes

1. Interface

 

Interface type

PROFINET

Physics

Ethernet

Isolated

Yes

automatic detection of transmission rate

Yes

Autonegotiation

Yes

Autocrossing

Yes

Functionality

 

  • â—� PROFINET IO Controller

Yes

  • â—� PROFINET IO Device

Yes

  • â—� Open IE communication

Yes

  • â—� Web server

Yes

PROFINET IO Controller

 

  • â—� Transmission rate, max.

100 Mbit/s

Services

 

  • — Number of connectable IO Devices, max.

16

PROFINET IO Device

 

Services

 

  • — Shared device

Yes

  • — Number of IO Controllers with shared device, max.

2

Protocols

 

Supports protocol for PROFINET IO

Yes

PROFIBUS

Yes; CM 1243-5 required

AS-Interface

Yes

Protocols (Ethernet)

 

  • â—� TCP/IP

Yes

Open IE communication

 

  • â—� TCP/IP

Yes

  • â—� ISO-on-TCP (RFC1006)

Yes

  • â—� UDP

Yes

Web server

 

  • â—� User-defined websites

Yes

Further protocols

 

  • â—� MODBUS

Yes

Communication functions

 

S7 communication

 

  • â—� supported

Yes

  • â—� as server

Yes

  • â—� as client

Yes

Web server

 

  • â—� supported

Yes

Number of connections

 

  • â—� overall

16; dynamically

Test commissioning functions

 

Status/control

 

  • â—� Status/control variable

Yes

  • â—� Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

Forcing

 

  • â—� Forcing

Yes

Diagnostic buffer

 

  • â—� present

Yes

Traces

 

  • â—� Number of configurable Traces

2; Up to 512 KB of data per trace are possible

Integrated Functions

 

Number of counters

4

Counting frequency (counter) max.

100 kHz

Frequency measurement

Yes

controlled positioning

Yes

Number of position-controlled positioning axes, max.

8

Number of positioning axes via pulse-direction interface

4; With integrated DO

PID controller

Yes

Number of alarm inputs

4

Number of pulse outputs

4

Limit frequency (pulse)

100 kHz

Potential separation

 

Potential separation digital inputs

 

  • â—� Potential separation digital inputs

500V AC for 1 minute

  • â—� between the channels, in groups of

1

Potential separation digital outputs

 

  • â—� Potential separation digital outputs

Yes

  • â—� between the channels

No

  • â—� between the channels, in groups of

1

Isolation

 

Isolation tested with

According to EN 50155 (routine test)

EMC

 

Interference immunity against discharge of static electricity

 

  • â—� Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

Yes

  • — Test voltage at air discharge

8 kV

  • — Test voltage at contact discharge

6 kV

Interference immunity to cable-borne interference

 

  • â—� Interference immunity on supply lines acc. to IEC 61000-4-4

Yes

  • â—� Interference immunity on signal cables acc. to IEC 61000-4-4

Yes

Interference immunity against voltage surge

 

  • â—� on the supply lines acc. to IEC 61000-4-5

Yes

Interference immunity against conducted variable disturbance induced by high-frequency fields

 

  • â—� Interference immunity against high-frequency radiation acc. to IEC 61000-4-6

Yes

Emission of radio interference acc. to EN 55 011

 

  • â—� Limit class A, for use in industrial areas

Yes; Group 1

  • â—� Limit class B, for use in residential areas

Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011

Degree and class of protection

 

Degree of protection acc. to EN 60529

  • â—� IP20

Yes

Standards, approvals, certificates

 

Railway application

 

  • â—� EN 50121-3-2

Yes; EMC for rail vehicles

  • â—� EN 50121-4

Yes; EMC for signal and telecommunications systems

  • â—� EN 50124-1

Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

  • â—� EN 50125-1

Yes; Rail vehicles - see ambient conditions

  • â—� EN 50125-2

Yes; Stationary electrical equipment - see ambient conditions

  • â—� EN 50125-3

Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

  • â—� EN 50155

Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

  • â—� EN 61373

Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

  • â—� Fire protection acc. to EN 45545-2

Yes; Rail vehicles - verification on request

Ambient conditions

 

Free fall

 

  • â—� Fall height, max.

0.3 m; five times, in product package

Ambient temperature during operation

 

  • â—� horizontal installation, min.

-25 °C; = Tmin; Startup @ -25 °C

  • â—� horizontal installation, max.

60 °C; Number of simultaneously activated inputs or outputs: 4 or 3 (no adjacent points) at 60 °C horizontal, 8 or 6 at 55 °C horizontal; 70 °C for 10 minutes (T1 acc. to EN 50155)

Ambient temperature during storage/transportation

 

  • â—� min.

-40 °C

  • â—� max.

70 °C

Altitude during operation relating to sea level

 

  • â—� Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Relative humidity

 

  • â—� With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

Vibrations

 

  • â—� Vibration resistance during operation acc. to IEC 60068-2-6

2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail

  • â—� Operation, tested according to IEC 60068-2-6

Yes

Shock testing

 

  • â—� tested according to IEC 60068-2-27

Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms

Use in stationary industrial systems

 

  • — to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • — to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • — to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Use on land craft, rail vehicles and special-purpose vehicles

 

  • — to biologically active substances according to EN 60721-3-5

Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request

  • — to chemically active substances according to EN 60721-3-5

Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

  • — to mechanically active substances according to EN 60721-3-5

Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

Programming

 

Programming language

 

  • — LAD

Yes

  • — FBD

Yes

  • — SCL

Yes

Cycle time monitoring

 

  • â—� adjustable

Yes

Dimensions

 

Width

90 mm

Height

100 mm

Depth

75 mm

Weights

 

Weight, approx.

370 g

Other

 

Note:

For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776