Weighing modes | - Non-automatic scales, e.g. platform and hopper scales
|
Ports | - 1 x SIMATIC S7-1500 system bus
- 1 x Ethernet (SIWATOOL, Modbus TCP/IP)
- 1 x RS485 (Modbus RTU or remote display) per channel
- 3 x digital outputs (24 V DC) per channel
- 4 x digital outputs (24 V DC short-circuit proof) per channel
|
Functions | - 3 limits
- Zeroing
- Tare
- Tare specification
- Zero adjustment
- Trace function for signal analysis
- Internal restore point
- SIMATIC S7-1500 integrated and/or stand-alone operation
|
Parameter assignment | - By means of function block in SIMATIC S7-1500 and HMI
- Using SIWATOOL V7
- Using Modbus TCP/IP
- Using Modbus RTU
|
Remote display (see accessories) | |
Connection | via RS 485 |
Display | Additional display for weight value |
Measuring accuracy | |
Error limit according to DIN 1319-1 of full-scale value at 20 °C ± 10 K (68 °F ± 10 K) | 0.05% |
Internal resolution | Up to ±4 million parts |
Number of measurements/second | 100 or 120 (selectable) |
Filter | - Low-pass filter 0.05 ... 50 Hz
- Average value filter
|
Weighing functions | |
Weight values | |
Limit values | |
Zeroing | Per command |
Tare | Per command |
Tare specification | Per command |
Compatible sensors | Analog load cells / full-bridge strain gauges (1-4 mV/V) in 4-wire or 6-wire system |
Load cell powering | |
Supply voltage (regulated via feedback) | 4.85 V DC |
Permissible load resistance | |
| > 40 О© |
| < 4 100 О© |
With SIWAREX IS Ex interface | |
| > 50 О© |
| < 4 100 О© |
Load cell characteristic | 1 … 4 mV/V |
Permissible range of the measurement signal (with 4 mV/V sensors) | -21.3 ... +21.3 mV |
Max. distance of load cells | 800 m (2 624 ft) |
Connection to load cells in Ex zone 1 | Optionally via SIWAREX IS Ex interface |
Certificates | - ATEX Zone 2
- UL
- KCC
- EAC
- RCM
- FM
- IECEx
|
Auxiliary power supply | |
Rated voltage | 24 V DC |
Max. power consumption WP521 ST / WP522 ST | 120 mA / 200 mA |
Max. power consumption SIMATIC Bus | 35 mA @ 15 V |
IP degree of protection according to DIN EN 60529; IEC 60529 | IP20 |
Climatic requirements Tmin(IND) ... Tmax(IND) (operating temperature) | |
| -10 ... +60 °C (14 ... 140 °F) |
| -10 ... +40 °C (14 ... 104 °F) |
EMC requirements | according to IEC 61000-6-2:2004; IEC 61000-6-4:2007+A1:2011 |
Dimensions (W x H x D) | 35 x 147 x 129 mm (1.38 x 5.79 x 5.08 in) |