The ET 200SP motor starters are suitable for the following applications: - Switching and monitoring of
- 3-phase motors with overload and short-circuit protection (e.g. 400 V asynchronous motors for secondary drives in conveyor systems)
- 1-phase motors with overload and short-circuit protection (e.g. 230 V motors for pump applications)
- Resistive loads by means of current value and diagnosis via the maintenance function (e.g. for heaters)
- Plant monitoring and energy management in conveyor systems:
By means of phase asymmetry and zero current detection, for example, it is possible to monitor drive belts and blocking. - Track switching and lifting table control in conveyor systems:
Track switches can be implemented by means of the quick stop function and lifting table controls by means of the "immediate end position disconnection" function without any laborious programming. - Safe isolation of drive from main power supply:
The isolating functions in accordance with IEC 60947-1 offer protection against inadvertent activation during plant maintenance.
|
|