Transmission rate | | | |
Transfer rate | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s | 10 Mbit/s, 100 Mbit/s |
Interfaces for communication integrated | | | |
Number of electrical connections | | | |
| 4 | 2 | 1 |
Number of 100 Mbit/s SC ports | | | |
| 0 | 2 | 3 |
Number of 1000 Mbit/s LC ports | | | |
| 0 | 0 | 0 |
| 0 | 0 | 0 |
Interfaces others | | | |
Number of electrical connections | | | |
| 1 | 1 | 1 |
| 1 | 1 | 1 |
Type of electrical connection | | | |
| 5‑pin M12 socket | 5‑pin M12 socket | 5‑pin M12 socket |
| 5-pin push-pull plug PRO socket | 5-pin push-pull plug PRO socket | 5-pin push-pull plug PRO socket |
design of the removable storage | | | |
| Yes | Yes | Yes |
Signal-Inputs/outputs | | | |
Operating voltage of the signaling contacts | | | |
| 24 V | 24 V | 24 V |
Operating current of the signaling contacts | | | |
| 0.1 A | 0.1 A | 0.1 A |
Supply voltage, current consumption, power loss | | | |
Type of voltage of the supply voltage | DC | DC | DC |
Supply voltage | | | |
| 24 V | 24 V | 24 V |
| 18 V | 18 V | 18 V |
| 32 V | 32 V | 32 V |
Product component fusing at power supply input | Yes | Yes | Yes |
Fuse protection type at input for supply voltage | 0.6 A / 60 V | 1.1 A / 33 V | 1.1 A / 33 V |
Consumed current maximum | 0.2 A | 0.3 A | 0.33 A |
Power loss [W] | | | |
| 4.8 W | 7.2 W | 7.92 W |
Permitted ambient conditions | | | |
Ambient temperature | | | |
| -25 ... +70 °C | -25 ... +60 °C | -25 ... +60 °C |
| -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C |
| -40 ... +70 °C | -40 ... +70 °C | -40 ... +70 °C |
Relative humidity | | | |
| 95 % | 95 % | 95 % |
Protection class IP | IP65 | IP65 | IP65 |
Design, dimensions and weight | | | |
Design | compact | compact | compact |
Width | 90 mm | 90 mm | 90 mm |
Height | 125 mm | 125 mm | 125 mm |
Depth | 124 mm | 124 mm | 124 mm |
Net weight | 1 kg | 1 kg | 1 kg |
Mounting type | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
Product properties, functions, components general | | | |
Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s | 100 | 50 | 50 |
Cascading in cases of star topology | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) |
Product functions management, configuration | | | |
Product function | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Protocol is supported | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Identification & maintenance function | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Product functions Diagnosis | | | |
Product function | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Product functions DHCP | | | |
Product function | | | |
| Yes | Yes | Yes |
Product functions Redundancy | | | |
Product function | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Protocol is supported Media Redundancy Protocol (MRP) | Yes | Yes | Yes |
Product function | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
Product functions Security | | | |
Protocol is supported | | | |
| Yes | Yes | Yes |
Product functions Time | | | |
Product function | | | |
| Yes | Yes | Yes |
Protocol is supported | | | |
| No | No | No |
| Yes | Yes | Yes |
Standards, specifications, approvals | | | |
Standard | | | |
| FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
| EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
| UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 | UL 60950-1, CSA C22.2 No. 60950-1 |
| ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
| EN 61000-6-4:2001 (Class A) | EN 61000-6-4:2001 (Class A) | EN 61000-6-4:2001 (Class A) |
| EN 61000-6-4:2001 | EN 61000-6-4:2001 | EN 61000-6-4:2001 |
Standards, specifications, approvals CE | | | |
Certificate of suitability CE marking | Yes | Yes | Yes |
Standards, specifications, approvals miscellaneous | | | |
Certificate of suitability | EN 61000-6-4:2001 | EN 61000-6-4:2001 | EN 61000-6-4:2001 |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
Standards, specifications, approvals ship classification | | | |
Marine classification association | | | |
| Yes | | |
| Yes | | |
| Yes | | |
| No | | |
| Yes | | |
| Yes | | |
| No | | |
| No | | |
Standards, specifications, approvals product conformity | | | |
MTBF at 40 °C | 98.55 y | 84.99 y | 84.99 y |
Accessories | | | |
Product extension optional C-PLUG | Yes | Yes | Yes |