General information | | | |
Product type designation | KTP900 Basic color PN | KTP1200 Basic color PN | KTP1200 Basic color DP |
Display | | | |
Design of display | TFT widescreen display, LED backlighting | TFT widescreen display, LED backlighting | TFT widescreen display, LED backlighting |
Screen diagonal | 9 in | 12 in | 12 in |
Display width | 198 mm | 261.1 mm | 261.1 mm |
Display height | 111.7 mm | 163.2 mm | 163.2 mm |
Number of colors | 65 536 | 65 536 | 65 536 |
Resolution (pixels) | | | |
| 800 Pixel | 1 280 Pixel | 1 280 Pixel |
| 480 Pixel | 800 Pixel | 800 Pixel |
Backlighting | | | |
| 20 000 h | 20 000 h | 20 000 h |
| Yes | Yes | Yes |
Keyboard fonts | | | |
| | | |
| 8 | 10 | 10 |
| No | No | No |
| No | No | No |
| Yes; Onscreen keyboard | Yes; Onscreen keyboard | Yes; Onscreen keyboard |
| Yes; Onscreen keyboard | Yes; Onscreen keyboard | Yes; Onscreen keyboard |
Touch operation | | | |
| Yes | Yes | Yes |
Installation type/mounting | | | |
Mounting in portrait format possible | Yes | Yes | Yes |
Mounting in landscape format possible | Yes | Yes | Yes |
maximum permissible angle of inclination without external ventilation | 35° | 35° | 35° |
Supply voltage | | | |
Type of supply voltage | DC | DC | DC |
Rated value (DC) | 24 V | 24 V | 24 V |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V |
Input current | | | |
Current consumption (rated value) | 230 mA | 510 mA | 550 mA |
Starting current inrush IІt | 0.2 AІ·s | 0.2 AІ·s | 0.2 AІ·s |
Power | | | |
Active power input, typ. | 5.5 W | 12.2 W | 13.2 W |
Processor | | | |
Processor type | ARM | ARM | ARM |
Memory | | | |
Flash | Yes | Yes | Yes |
RAM | Yes | Yes | Yes |
Memory available for user data | 10 Mbyte | 10 Mbyte | 10 Mbyte |
Type of output | | | |
Acoustics | | | |
| Yes | Yes | Yes |
| No | No | No |
Time of day | | | |
Clock | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes; Back-up duration typically 6 weeks | Yes; Back-up duration typically 6 weeks |
| Yes | Yes | Yes |
Interfaces | | | |
Number of industrial Ethernet interfaces | 1 | 1 | 0 |
Number of RS 485 interfaces | 0 | 0 | 1 |
Number of RS 422 interfaces | 0 | 0 | 1; together with RS485 |
Number of RS 232 interfaces | 0 | 0 | 0; with optional adapter |
Number of USB interfaces | 1; Up to 16 GB | 1; Up to 16 GB | 1; Up to 16 GB |
Number of 20 mA interfaces (TTY) | 0 | 0 | 0 |
Number of parallel interfaces | 0 | 0 | 0 |
Number of other interfaces | 0 | 0 | 0 |
Number of SD card slots | 0 | 0 | 0 |
With software interfaces | No | No | No |
Industrial Ethernet | | | |
| 2 | 2 | 0 |
Protocols | | | |
PROFINET | Yes | Yes | No |
Supports protocol for PROFINET IO | No | No | No |
IRT | No | No | No |
MRP | | No | No |
PROFIBUS | No | No | Yes |
MPI | No | No | Yes |
Protocols (Ethernet) | | | |
| Yes | Yes | No |
| Yes | Yes | No |
| Yes | Yes | No |
| Yes | Yes | No |
| Yes | Yes | No |
WEB characteristics | | | |
| No | No | No |
| No | No | No |
Further protocols | | | |
| No | No | No |
| Yes | Yes | No |
| Yes; Modicon (MODBUS TCP/IP) | Yes; Modicon (MODBUS TCP/IP) | Yes; Modicon (MODBUS RTU) |
Interrupts/diagnostics/status information | | | |
Diagnostic messages | | | |
| No | No | No |
EMC | | | |
Emission of radio interference acc. to EN 55 011 | | | |
| Yes | Yes | Yes |
| No | No | No |
Degree and class of protection | | | |
IP (at the front) | IP65 | IP65 | IP65 |
Enclosure Type 4 at the front | Yes | Yes | Yes |
Enclosure Type 4x at the front | Yes | Yes | Yes |
IP (rear) | IP20 | IP20 | IP20 |
Standards, approvals, certificates | | | |
CE mark | Yes | Yes | Yes |
KC approval | | Yes | Yes |
Use in hazardous areas | | | |
| No | No | No |
| No | No | No |
| | No | No |
| | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
Ambient conditions | | | |
Suited for indoor use | Yes | Yes | Yes |
Suited for outdoor use | No | No | No |
Ambient temperature during operation | | | |
| | | |
| -20 °C | -10 °C; = Tmin | -10 °C; = Tmin |
| 50 °C | 50 °C | 50 °C |
| | | |
| -20 °C | -10 °C; = Tmin | -10 °C; = Tmin |
| 40 °C | 40 °C | 40 °C |
| | | |
| -20 °C | -10 °C; = Tmin | -10 °C; = Tmin |
| 40 °C | 40 °C | 40 °C |
| | | |
| -20 °C | -10 °C; = Tmin | -10 °C; = Tmin |
| 35 °C | 35 °C | 35 °C |
Ambient temperature during storage/transportation | | | |
| -20 °C | -20 °C | -20 °C |
| 60 °C | 60 °C | 60 °C |
Altitude during operation relating to sea level | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation/frost (no commissioning when condensation present), vertical mounting position |
Use in stationary industrial systems | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Operating systems | | | |
proprietary | Yes | Yes | Yes |
pre-installed operating system | | | |
| No | No | No |
Configuration | | | |
Message indicator | Yes | Yes | Yes |
Alarm system (incl. buffer and acknowledgment) | Yes | Yes | Yes |
Process value display (output) | Yes | Yes | Yes |
Process value default (input) possible | Yes | Yes | Yes |
Recipe management | Yes | Yes | Yes |
Configuration software | | | |
| Yes; via integrated WinCC Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) |
| Yes; via integrated WinCC Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) |
| No | No | No |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Languages | | | |
Online languages | | | |
| 10 | 10 | 10 |
Project languages | | | |
| 32 | 32 | 32 |
Functionality under WinCC (TIA Portal) | | | |
Libraries | Yes | Yes | Yes |
Applications/options | | | |
| | Yes | Yes |
Number of Visual Basic Scripts | No | No | No |
Task planner | Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
Help system | Yes | Yes | Yes |
| 500 | 500 | 500 |
Message system | | | |
| 32 | 32 | 32 |
| | | |
| 1 000 | 1 000 | 1 000 |
| | | |
| 25 | 25 | 25 |
| No | No | No |
| Yes | Yes | Yes |
в—Џ System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)
| Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 | Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 | Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 |
| 80 | 80 | 80 |
| 8 | 8 | 8 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | | |
| 256 | 256 | 256 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Recipe management | | | |
| 50 | 50 | 50 |
| 100 | 100 | 100 |
| 100 | 100 | 100 |
| 256 kbyte | 256 kbyte | 256 kbyte |
| No | No | No |
Variables | | | |
| 800 | 800 | 800 |
| 100 | 100 | 100 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
Images | | | |
| 250 | 250 | 250 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Image objects | | | |
| 100 | 100 | 100 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Complex image objects | | | |
| 10 | 10 | 10 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
| Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 | Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 | Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| No | No | No |
Lists | | | |
| 150 | 300 | 300 |
| 100 | 100 | 100 |
| 100 | 100 | 100 |
| 100 | 100 | 100 |
Archiving | | | |
| 2 | 2 | 2 |
| 10 000 | 10 000 | 10 000 |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| | | |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
| | | |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
Security | | | |
| 50 | 50 | 50 |
| 32 | 32 | 32 |
| 50 | 50 | 50 |
| Yes; Possible via ProSave | Yes | Yes |
| No | No | No |
Character sets | | | |
| | | |
| Yes | Yes | Yes |
Transfer (upload/download) | | | |
| No | No | Yes |
| No | No | No |
| Yes | Yes | No |
| No | No | No |
Process coupling | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | Yes; No access to NCK data | Yes; No access to NCK data |
| Yes | Yes | Yes |
| Yes | Yes | No |
| No | No | Yes |
| Yes | Yes | No |
| No | No | Yes |
| No | No | No |
| No | No | Yes |
| Yes | Yes | No |
| No | No | Yes |
Service tools/configuration aids | | | |
| Yes; Possible via ProSave | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Peripherals/Options | | | |
Peripherals | | | |
| No | No | No |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
Mechanics/material | | | |
Enclosure material (front) | | | |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
Dimensions | | | |
Width of the housing front | 267 mm | 330 mm | 330 mm |
Height of housing front | 182 mm | 245 mm | 245 mm |
Mounting cutout, width | 251 mm | 310 mm | 310 mm |
Mounting cutout, height | 166 mm | 221 mm | 221 mm |
Overall depth | 55 mm | 60 mm | 60 mm |
Weights | | | |
Weight without packaging | 1 130 g | 1 710 g | 1 710 g |
Weight incl. packaging | 1 393 g | 2.2 kg | 2.2 kg |