Integration in automation systems | |
S7-1200 | SIMATIC S7-1200 system bus |
Operator panel and/or automation systems from other vendors | Via Ethernet (Modbus TCP/IP) or RS 485 (Modbus RTU) |
Communication interfaces | - SIMATIC S7-1200 backplane bus
- RS 485 (Modbus RTU)
- Ethernet (SIWATOOL V7, Modbus TCP/IP)
- Analog output 0/4 - 20 mA
- 4 x digital outputs, 24 V DC floating, short-circuit proof
- 4 x digital outputs, 24 V DC, floating
|
Commissioning options | - Using SIWATOOL V7
- Using function block in SIMATIC S7-1200 CPU / Touch Panel
- Using Modbus TCP/IP
- Using Modbus RTU
|
Measuring accuracy | |
Error limit according to DIN 1319-1 of full-scale value at 20 °C ± 10 K (68 °F ± 10 K) | 0.05% |
Internal resolution | up to ±4 million parts |
Measuring frequency | 100 / 120 Hz |
Digital filter | Separate, variable adjustable low-pass and average filter for loading and speed |
Filter for conveyor load | Low-pass filter (limit frequency 0.05 ... 50 Hz) |
Filter for belt speed | Low-pass filter (limit frequency 0.05 ... 50 Hz) |
Weighing functions | |
Readout data | - Weight
- Belt load
- Material flow rate
- Accumulated total
- Main total
- Free totals 1 … 4
- Belt speed
|
Limits (min/max) | - Belt load
- Material flow rate
- Belt speed
|
Load cells | Full-bridge strain gauges in 4-wire or 6-wire system |
Load cell excitation | |
Supply voltage (regulated via feedback) | 4.85 V DC |
Permissible load resistance | |
| > 40 О© |
| < 4100 О© |
With SIWAREX IS Ex interface | |
| > 50 О© |
| < 4100 О© |
Load cell characteristic | 1 … 4 mV/V |
Permissible measurement signal range | -21.3 ... +21.3 mV |
Max. distance of load cells | 500 m (229.66 ft) |
Connection to load cells in Ex zone 1 | Optionally via SIWAREX IS Ex interface (compatibility of the load cells must be checked) |
Approvals/certificates | |
Auxiliary power supply | |
Rated voltage | 24 V DC |
Max. power consumption | 200 mA |
Max. power consumption SIMATIC Bus | 3 mA |
IP degree of protection to DIN EN 60529; IEC 60529 | IP20 |
Climatic requirements Tmin (IND) ... Tmax (IND) (operating temperature) | |
| -10 ... +40 °C (14 ... 104 °F) |
| -10 ... +55 °C (14 ... 131 °F) |
EMC requirements | according to EN 45501 |
Dimensions | 70 x 75 x 100 mm (2.76 x 2.95 x 3.94 in) |