Article number

6ES7510-1DJ01-0AB0

CPU 1510SP-1 PN, 100KB PROG./750KB DATA

General information

 

Product type designation

CPU 1510SP-1 PN

HW functional status

FS03

Firmware version

V2.5

Product function

 

  • â—� I&M data

Yes; I&M0 to I&M3

  • â—� Module swapping during operation (hot swapping)

Yes; Multi-hot swapping

Engineering with

 

  • â—� STEP 7 TIA Portal configurable/integrated as of version

V15 (FW V2.5) / V13 SP1 Update 4 (FW V1.8) or higher

Configuration control

 

via dataset

Yes

Control elements

 

Mode selector switch

1

Supply voltage

 

Type of supply voltage

24 V DC

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

Reverse polarity protection

Yes

Mains buffering

 

  • â—� Mains/voltage failure stored energy time

5 ms

Input current

 

Current consumption (rated value)

0.6 A

Inrush current, max.

4.7 A; Rated value

I²t

0.14 A²·s

Power

 

Infeed power to the backplane bus

8.75 W

Power loss

 

Power loss, typ.

5.6 W

Memory

 

Number of slots for SIMATIC memory card

1

SIMATIC memory card required

Yes

Work memory

 

  • â—� integrated (for program)

100 kbyte

  • â—� integrated (for data)

750 kbyte

Load memory

 

  • â—� Plug-in (SIMATIC Memory Card), max.

32 Gbyte

Backup

 

  • â—� maintenance-free

Yes

CPU processing times

 

for bit operations, typ.

72 ns

for word operations, typ.

86 ns

for fixed point arithmetic, typ.

115 ns

for floating point arithmetic, typ.

461 ns

CPU-blocks

 

Number of elements (total)

2 000; Blocks (OB, FB, FC, DB) and UDTs

DB

 

  • â—� Number range

1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999

  • â—� Size, max.

750 kbyte; For DBs with absolute addressing, the max. size is 64 KB

FB

 

  • â—� Number range

0 ... 65 535

  • â—� Size, max.

100 kbyte

FC

 

  • â—� Number range

0 ... 65 535

  • â—� Size, max.

100 kbyte

OB

 

  • â—� Size, max.

100 kbyte

  • â—� Number of free cycle OBs

100

  • â—� Number of time alarm OBs

20

  • â—� Number of delay alarm OBs

20

  • â—� Number of cyclic interrupt OBs

20; With minimum OB 3x cycle of 500 µs

  • â—� Number of process alarm OBs

50

  • â—� Number of DPV1 alarm OBs

3

  • â—� Number of isochronous mode OBs

1

  • â—� Number of technology synchronous alarm OBs

2

  • â—� Number of startup OBs

100

  • â—� Number of asynchronous error OBs

4

  • â—� Number of synchronous error OBs

2

  • â—� Number of diagnostic alarm OBs

1

Nesting depth

 

  • â—� per priority class

24

Counters, timers and their retentivity

 

S7 counter

 

  • â—� Number

2 048

Retentivity

 

  • — adjustable

Yes

IEC counter

 

  • â—� Number

Any (only limited by the main memory)

Retentivity

 

  • — adjustable

Yes

S7 times

 

  • â—� Number

2 048

Retentivity

 

  • — adjustable

Yes

IEC timer

 

  • â—� Number

Any (only limited by the main memory)

Retentivity

 

  • — adjustable

Yes

Data areas and their retentivity

 

Retentive data area (incl. timers, counters, flags), max.

128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB

Flag

 

  • â—� Number, max.

16 kbyte

  • â—� Number of clock memories

8; 8 clock memory bits, grouped into one clock memory byte

Data blocks

 

  • â—� Retentivity adjustable

Yes

  • â—� Retentivity preset

No

Local data

 

  • â—� per priority class, max.

64 kbyte; max. 16 KB per block

Address area

 

Number of IO modules

1 024; max. number of modules / submodules

I/O address area

 

  • â—� Inputs

32 kbyte; All inputs are in the process image

  • â—� Outputs

32 kbyte; All outputs are in the process image

per integrated IO subsystem

 

  • — Inputs (volume)

8 kbyte

  • — Outputs (volume)

8 kbyte

per CM/CP

 

  • — Inputs (volume)

8 kbyte

  • — Outputs (volume)

8 kbyte

Subprocess images

 

  • â—� Number of subprocess images, max.

32

Address space per module

 

  • â—� Address space per module, max.

288 byte; For input and output data respectively

Address space per station

 

  • â—� Address space per station, max.

2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules

Hardware configuration

 

Number of distributed IO systems

32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)

Number of DP masters

 

  • â—� Via CM

1

Number of IO Controllers

 

  • â—� integrated

1

  • â—� Via CM

0

Rack

 

  • â—� Modules per rack, max.

80; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules

  • â—� Number of lines, max.

1

PtP CM

 

  • â—� Number of PtP CMs

the number of connectable PtP CMs is only limited by the number of available slots

Time of day

 

Clock

 

  • â—� Type

Hardware clock

  • â—� Backup time

6 wk; At 40 °C ambient temperature, typically

  • â—� Deviation per day, max.

10 s; Typ.: 2 s

Operating hours counter

 

  • â—� Number

16

Clock synchronization

 

  • â—� supported

Yes

  • â—� to DP, master

Yes; Via CM DP module

  • â—� to DP, slave

Yes; Via CM DP module

  • â—� in AS, master

Yes

  • â—� in AS, slave

Yes

  • â—� on Ethernet via NTP

Yes

Interfaces

 

Number of PROFINET interfaces

1

Number of PROFIBUS interfaces

1; Via CM DP module

With optical interface

No

1. Interface

 

Interface types

 

  • â—� Number of ports

3; 1. integr. + 2. via BusAdapter

  • â—� integrated switch

Yes

  • â—� RJ 45 (Ethernet)

Yes; X1 P3; opt. X1 P1 and X1 P2 via BusAdapter BA 2x RJ45

  • â—� BusAdapter (PROFINET)

Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC

Functionality

 

  • â—� IP protocol

Yes; IPv4

  • â—� PROFINET IO Controller

Yes

  • â—� PROFINET IO Device

Yes

  • â—� SIMATIC communication

Yes

  • â—� Open IE communication

Yes

  • â—� Web server

Yes

  • â—� Media redundancy

Yes; MRP Automanager according to IEC 62439-2 Edition 2.0

PROFINET IO Controller

 

Services

 

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — Isochronous mode

Yes

  • — Open IE communication

Yes

  • — IRT

Yes

  • — MRP

Yes; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50

  • — MRPD

Yes; Requirement: IRT

  • — PROFIenergy

Yes

  • — Prioritized startup

Yes; Max. 32 PROFINET devices

  • — Number of connectable IO Devices, max.

64; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET

  • — Of which IO devices with IRT, max.

64

  • — Number of connectable IO Devices for RT, max.

64

  • — of which in line, max.

64

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8; in total across all interfaces

  • — Number of IO Devices per tool, max.

8

  • — Updating times

The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data

Update time for IRT

 

  • — for send cycle of 250 µs

250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive

  • — for send cycle of 500 µs

500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive

  • — for send cycle of 1 ms

1 ms to 16 ms

  • — for send cycle of 2 ms

2 ms to 32 ms

  • — for send cycle of 4 ms

4 ms to 64 ms

  • — With IRT and parameterization of "odd" send cycles

Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)

Update time for RT

 

  • — for send cycle of 250 µs

250 µs to 128 ms

  • — for send cycle of 500 µs

500 µs to 256 ms

  • — for send cycle of 1 ms

1 ms to 512 ms

  • — for send cycle of 2 ms

2 ms to 512 ms

  • — for send cycle of 4 ms

4 ms to 512 ms

PROFINET IO Device

 

Services

 

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — Isochronous mode

No

  • — Open IE communication

Yes

  • — IRT

Yes

  • — MRP

Yes

  • — MRPD

Yes; Requirement: IRT

  • — PROFIenergy

Yes

  • — Shared device

Yes

  • — Number of IO Controllers with shared device, max.

4

  • — Asset management record

Yes; Per user program

2. Interface

 

Interface types

 

  • â—� Number of ports

1

  • â—� RS 485

Yes; Via CM DP module

Functionality

 

  • â—� PROFIBUS DP master

Yes

  • â—� PROFIBUS DP slave

Yes

  • â—� SIMATIC communication

Yes

Interface types

 

RJ 45 (Ethernet)

 

  • â—� 100 Mbps

Yes

  • â—� Autonegotiation

Yes

  • â—� Autocrossing

Yes

  • â—� Industrial Ethernet status LED

Yes

RS 485

 

  • â—� Transmission rate, max.

12 Mbit/s

Protocols

 

Number of connections

 

  • â—� Number of connections, max.

96; via integrated interfaces of the CPU and connected CPs / CMs

  • â—� Number of connections reserved for ES/HMI/web

10

  • â—� Number of connections via integrated interfaces

64

  • â—� Number of connections per CP/CM

32

  • â—� Number of S7 routing paths

16

SIMATIC communication

 

  • â—� S7 communication, as server

Yes

  • â—� S7 communication, as client

Yes

  • â—� User data per job, max.

See online help (S7 communication, user data size)

Open IE communication

 

  • â—� TCP/IP

Yes

  • — Data length, max.

64 kbyte

  • — several passive connections per port, supported

Yes

  • â—� ISO-on-TCP (RFC1006)

Yes

  • — Data length, max.

64 kbyte

  • â—� UDP

Yes

  • — Data length, max.

2 kbyte; 1 472 bytes for UDP broadcast

  • — UDP multicast

Yes; Max. 5 multicast circuits

  • â—� DHCP

No

  • â—� SNMP

Yes

  • â—� DCP

Yes

  • â—� LLDP

Yes

Web server

 

  • â—� HTTP

Yes; Standard and user pages

  • â—� HTTPS

Yes; Standard and user pages

PROFIBUS DP master

 

  • â—� Number of connections, max.

48

Services

 

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — Data record routing

Yes

  • — Isochronous mode

No

  • — Equidistance

No

  • — Number of DP slaves

125; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET

  • — Activation/deactivation of DP slaves

Yes

OPC UA

 

  • â—� Runtime license required

Yes

  • â—� OPC UA Server

Yes; Data access (read, write, subscribe), method call, custom address space

  • — Application authentication

Yes

  • — Security policies

Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256

  • — User authentication

"anonymous" or by user name & password

Further protocols

 

  • â—� MODBUS

Yes; MODBUS TCP

Media redundancy

 

  • â—� Switchover time on line break, typ.

200 ms; For MRP, bumpless for MRPD

  • â—� Number of stations in the ring, max.

50

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes; Only with PROFINET; with minimum OB 6x cycle of 625 µs

S7 message functions

 

Number of login stations for message functions, max.

32

Program alarms

Yes

Number of configurable program alarms

5 000

Number of simultaneously active program alarms

  • â—� Number of program alarms

300

  • â—� Number of alarms for system diagnostics

100

  • â—� Number of alarms for motion technology objects

80

Test commissioning functions

 

Joint commission (Team Engineering)

Yes; Parallel online access possible for up to 5 engineering systems

Status block

Yes; Up to 8 simultaneously (in total across all ES clients)

Single step

No

Number of breakpoints

8

Status/control

 

  • â—� Status/control variable

Yes

  • â—� Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

  • â—� Number of variables, max.

  • — of which status variables, max.

200; per job

  • — of which control variables, max.

200; per job

Forcing

 

  • â—� Forcing

Yes

  • â—� Forcing, variables

Peripheral inputs/outputs

  • â—� Number of variables, max.

200

Diagnostic buffer

 

  • â—� present

Yes

  • â—� Number of entries, max.

1 000

  • — of which powerfail-proof

500

Traces

 

  • â—� Number of configurable Traces

4; Up to 512 KB of data per trace are possible

Interrupts/diagnostics/status information

 

Diagnostics indication LED

 

  • â—� RUN/STOP LED

Yes

  • â—� ERROR LED

Yes

  • â—� MAINT LED

Yes

  • â—� Monitoring of the supply voltage (PWR-LED)

Yes

  • â—� Connection display LINK TX/RX

Yes

Supported technology objects

 

Motion Control

Yes; Note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool or SIZER

  • â—� Number of available Motion Control resources for technology objects (except cam disks)

800

  • â—� Required Motion Control resources

  • — per speed-controlled axis

40

  • — per positioning axis

80

  • — per synchronous axis

160

  • — per external encoder

80

  • — per output cam

20

  • — per cam track

160

  • — per probe

40

  • â—� Positioning axis

  • — Number of positioning axes at motion control cycle of 4 ms (typical value)

5

  • — Number of positioning axes at motion control cycle of 8 ms (typical value)

10

Controller

  • â—� PID_Compact

Yes; Universal PID controller with integrated optimization

  • â—� PID_3Step

Yes; PID controller with integrated optimization for valves

  • â—� PID-Temp

Yes; PID controller with integrated optimization for temperature

Counting and measuring

  • â—� High-speed counter

Yes

Ambient conditions

 

Ambient temperature during operation

 

  • â—� horizontal installation, min.

0 °C

  • â—� horizontal installation, max.

60 °C

  • â—� vertical installation, min.

0 °C

  • â—� vertical installation, max.

50 °C

Ambient temperature during storage/transportation

 

  • â—� min.

-40 °C

  • â—� max.

70 °C

Configuration

 

Programming

 

Programming language

 

  • — LAD

Yes

  • — FBD

Yes

  • — STL

Yes

  • — SCL

Yes

  • — GRAPH

Yes

Know-how protection

 

  • â—� User program protection/password protection

Yes

  • â—� Copy protection

Yes

  • â—� Block protection

Yes

Access protection

 

  • â—� Protection level: Write protection

Yes

  • â—� Protection level: Read/write protection

Yes

  • â—� Protection level: Complete protection

Yes

Cycle time monitoring

 

  • â—� lower limit

adjustable minimum cycle time

  • â—� upper limit

adjustable maximum cycle time

Dimensions

 

Width

100 mm

Height

117 mm

Depth

75 mm

Weights

 

Weight, approx.

310 g