Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6ES7534-7QE00-0AB0

S7-1500, AI 4X U/I/RTD/TC/AQ 2X U/I ST

General information

 

Product type designation

AI 4xU/I/RTD/TC /AQ 2xU/I ST

HW functional status

FS01

Firmware version

V1.0.0

  • â—� FW update possible

Yes

Product function

 

  • â—� I&M data

Yes; I&M0 to I&M3

  • â—� Measuring range scalable

No

  • â—� Scalable measured values

No

  • â—� Adjustment of measuring range

No

  • â—� Output range scalable

No

Engineering with

 

  • â—� STEP 7 TIA Portal configurable/integrated as of version

V13 / V13.0.2

  • â—� STEP 7 configurable/integrated as of version

V5.5 SP3 / -

  • â—� PROFIBUS as of GSD version/GSD revision

V1.0 / V5.1

  • â—� PROFINET as of GSD version/GSD revision

V2.3 / -

Operating mode

 

  • â—� Oversampling

No

  • â—� MSI

Yes

  • â—� MSO

Yes

CiR – Configuration in RUN

 

Reparameterization possible in RUN

Yes

Calibration possible in RUN

Yes

Supply voltage

 

Rated value (DC)

24 V

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

Reverse polarity protection

Yes

Input current

 

Current consumption, max.

200 mA; with 24 V DC supply

Encoder supply

 

24 V encoder supply

 

  • â—� Short-circuit protection

Yes

  • â—� Output current, max.

20 mA; Max. 47 mA per channel for a duration < 10 s

Power

 

Power available from the backplane bus

0.7 W

Power loss

 

Power loss, typ.

3.3 W

Analog inputs

 

Number of analog inputs

4

  • â—� For current measurement

4

  • â—� For voltage measurement

4

  • â—� For resistance/resistance thermometer measurement

2

  • â—� For thermocouple measurement

4

permissible input voltage for voltage input (destruction limit), max.

28.8 V

permissible input current for current input (destruction limit), max.

40 mA

Technical unit for temperature measurement adjustable

Yes; °C/°F/K

Analog input with oversampling

No

Standardization of measured values

No

Input ranges (rated values), voltages

 

  • â—� 0 to +5 V

No

  • â—� 0 to +10 V

No

  • â—� 1 V to 5 V

Yes

  • â—� Input resistance (1 V to 5 V)

100 kΩ

  • â—� -1 V to +1 V

Yes

  • â—� Input resistance (-1 V to +1 V)

10 MΩ

  • â—� -10 V to +10 V

Yes

  • â—� Input resistance (-10 V to +10 V)

100 kΩ

  • â—� -2.5 V to +2.5 V

Yes

  • â—� Input resistance (-2.5 V to +2.5 V)

10 MΩ

  • â—� -25 mV to +25 mV

No

  • â—� -250 mV to +250 mV

Yes

  • â—� Input resistance (-250 mV to +250 mV)

10 MΩ

  • â—� -5 V to +5 V

Yes

  • â—� Input resistance (-5 V to +5 V)

100 kΩ

  • â—� -50 mV to +50 mV

Yes

  • â—� Input resistance (-50 mV to +50 mV)

10 MΩ

  • â—� -500 mV to +500 mV

Yes

  • â—� Input resistance (-500 mV to +500 mV)

10 MΩ

  • â—� -80 mV to +80 mV

Yes

  • â—� Input resistance (-80 mV to +80 mV)

10 MΩ

Input ranges (rated values), currents

 

  • â—� 0 to 20 mA

Yes

  • â—� Input resistance (0 to 20 mA)

25 â„¦; Plus approx. 42 ohms for overvoltage protection by PTC

  • â—� -20 mA to +20 mA

Yes

  • â—� Input resistance (-20 mA to +20 mA)

25 â„¦; Plus approx. 42 ohms for overvoltage protection by PTC

  • â—� 4 mA to 20 mA

Yes

  • â—� Input resistance (4 mA to 20 mA)

25 â„¦; Plus approx. 42 ohms for overvoltage protection by PTC

Input ranges (rated values), thermocouples

 

  • â—� Type B

Yes

  • â—� Input resistance (Type B)

10 MΩ

  • â—� Type C

No

  • â—� Type E

Yes

  • â—� Input resistance (Type E)

10 MΩ

  • â—� Type J

Yes

  • â—� Input resistance (type J)

10 MΩ

  • â—� Type K

Yes

  • â—� Input resistance (Type K)

10 MΩ

  • â—� Type L

No

  • â—� Type N

Yes

  • â—� Input resistance (Type N)

10 MΩ

  • â—� Type R

Yes

  • â—� Input resistance (Type R)

10 MΩ

  • â—� Type S

Yes

  • â—� Input resistance (Type S)

10 MΩ

  • â—� Type T

Yes

  • â—� Input resistance (Type T)

10 MΩ

  • â—� Type U

No

  • â—� Type TXK/TXK(L) to GOST

No

Input ranges (rated values), resistance thermometer

 

  • â—� Cu 10

No

  • â—� Cu 10 according to GOST

No

  • â—� Cu 50

No

  • â—� Cu 50 according to GOST

No

  • â—� Cu 100

No

  • â—� Cu 100 according to GOST

No

  • â—� Ni 10

No

  • â—� Ni 10 according to GOST

No

  • â—� Ni 100

Yes; Standard/climate

  • â—� Input resistance (Ni 100)

10 MΩ

  • â—� Ni 100 according to GOST

No

  • â—� Ni 1000

Yes; Standard/climate

  • â—� Input resistance (Ni 1000)

10 MΩ

  • â—� Ni 1000 according to GOST

No

  • â—� LG-Ni 1000

Yes; Standard/climate

  • â—� Input resistance (LG-Ni 1000)

10 MΩ

  • â—� Ni 120

No

  • â—� Ni 120 according to GOST

No

  • â—� Ni 200

No

  • â—� Ni 200 according to GOST

No

  • â—� Ni 500

No

  • â—� Ni 500 according to GOST

No

  • â—� Pt 10

No

  • â—� Pt 10 according to GOST

No

  • â—� Pt 50

No

  • â—� Pt 50 according to GOST

No

  • â—� Pt 100

Yes; Standard/climate

  • â—� Input resistance (Pt 100)

10 MΩ

  • â—� Pt 100 according to GOST

No

  • â—� Pt 1000

Yes; Standard/climate

  • â—� Input resistance (Pt 1000)

10 MΩ

  • â—� Pt 1000 according to GOST

No

  • â—� Pt 200

Yes; Standard/climate

  • â—� Input resistance (Pt 200)

10 MΩ

  • â—� Pt 200 according to GOST

No

  • â—� Pt 500

Yes; Standard/climate

  • â—� Input resistance (Pt 500)

10 MΩ

  • â—� Pt 500 according to GOST

No

Input ranges (rated values), resistors

 

  • â—� 0 to 150 ohms

Yes

  • â—� Input resistance (0 to 150 ohms)

10 MΩ

  • â—� 0 to 300 ohms

Yes

  • â—� Input resistance (0 to 300 ohms)

10 MΩ

  • â—� 0 to 600 ohms

Yes

  • â—� Input resistance (0 to 600 ohms)

10 MΩ

  • â—� 0 to 3000 ohms

No

  • â—� 0 to 6000 ohms

Yes

  • â—� Input resistance (0 to 6000 ohms)

10 MΩ

  • â—� PTC

Yes

  • â—� Input resistance (PTC)

10 MΩ

Thermocouple (TC)

 

Temperature compensation

 

  • — parameterizable

Yes

  • — internal temperature compensation

Yes

  • — external temperature compensation via RTD

Yes

  • — Compensation for 0 °C reference point temperature

Yes; fixed value can be set

  • — Reference channel of the module

No

Cable length

 

  • â—� shielded, max.

800 m; for U/I, 200 m for R/RTD, 50 m for TC

Analog outputs

 

Number of analog outputs

2

Voltage output, short-circuit protection

Yes

Voltage output, short-circuit current, max.

24 mA

Current output, no-load voltage, max.

22 V

Cycle time (all channels), min.

3.2 ms; ±0.5 ms, regardless of the number of activated channels

Output ranges, voltage

 

  • â—� 0 to 10 V

Yes

  • â—� 1 V to 5 V

Yes

  • â—� -5 V to +5 V

No

  • â—� -10 V to +10 V

Yes

Output ranges, current

 

  • â—� 0 to 20 mA

Yes

  • â—� -20 mA to +20 mA

Yes

  • â—� 4 mA to 20 mA

Yes

Connection of actuators

 

  • â—� for voltage output two-wire connection

Yes

  • â—� for voltage output four-wire connection

Yes

  • â—� for current output two-wire connection

Yes

Load impedance (in rated range of output)

 

  • â—� with voltage outputs, min.

1 kΩ; 0.5 kOhm at 1 to 5 V

  • â—� with voltage outputs, capacitive load, max.

1 µF

  • â—� with current outputs, max.

750 â„¦

  • â—� with current outputs, inductive load, max.

10 mH

Cable length

 

  • â—� shielded, max.

800 m; for current, 200 m for voltage

Analog value generation for the inputs

 

Integration and conversion time/resolution per channel

 

  • â—� Resolution with overrange (bit including sign), max.

16 bit

  • â—� Integration time, parameterizable

Yes

  • â—� Integration time (ms)

2,5 / 16,67 / 20 / 100 ms

  • â—� Basic conversion time, including integration time (ms)

9 / 23 / 27 / 107 ms

  • — additional conversion time for wire-break monitoring

9 ms

  • — additional conversion time for resistance measurement

150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms

  • â—� Interference voltage suppression for interference frequency f1 in Hz

400 / 60 / 50 / 10

  • â—� Time for offset calibration (per module)

Basic conversion time of the slowest channel

Smoothing of measured values

 

  • â—� parameterizable

Yes

  • â—� Step: None

Yes

  • â—� Step: low

Yes

  • â—� Step: Medium

Yes

  • â—� Step: High

Yes

Analog value generation for the outputs

 

Integration and conversion time/resolution per channel

 

  • â—� Resolution with overrange (bit including sign), max.

16 bit

  • â—� Conversion time (per channel)

0.5 ms

Settling time

 

  • â—� for resistive load

1.5 ms

  • â—� for capacitive load

2.5 ms

  • â—� for inductive load

2.5 ms

Encoder

 

Connection of signal encoders

 

  • â—� for voltage measurement

Yes

  • â—� for current measurement as 2-wire transducer

Yes

  • — Burden of 2-wire transmitter, max.

820 â„¦

  • â—� for current measurement as 4-wire transducer

Yes

  • â—� for resistance measurement with two-wire connection

Yes; Only for PTC

  • â—� for resistance measurement with three-wire connection

Yes; All measuring ranges except PTC; internal compensation of the cable resistances

  • â—� for resistance measurement with four-wire connection

Yes; All measuring ranges except PTC

Errors/accuracies

 

Linearity error (relative to input range), (+/-)

0.02 %

Temperature error (relative to input range), (+/-)

0.005 %/K; With TC type T 0.02 ± % / K

Crosstalk between the inputs, max.

-80 dB

Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)

0.02 %

Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)

0.02 %

Linearity error (relative to output range), (+/-)

0.15 %

Temperature error (relative to output range), (+/-)

0.002 %/K

Crosstalk between the outputs, max.

-100 dB

Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)

0.05 %

Temperature error of internal compensation

±6 °C

Operational error limit in overall temperature range

 

  • â—� Voltage, relative to input range, (+/-)

0.3 %

  • â—� Current, relative to input range, (+/-)

0.3 %

  • â—� Resistance, relative to input range, (+/-)

0.3 %

  • â—� Resistance thermometer, relative to input range, (+/-)

0.3 %; Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K

  • â—� Thermocouple, relative to input range, (+/-)

0.3 %; Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K

  • â—� Voltage, relative to output range, (+/-)

0.3 %

  • â—� Current, relative to output range, (+/-)

0.3 %

Basic error limit (operational limit at 25 °C)

 

  • â—� Voltage, relative to input range, (+/-)

0.1 %

  • â—� Current, relative to input range, (+/-)

0.1 %

  • â—� Resistance, relative to input range, (+/-)

0.1 %

  • â—� Resistance thermometer, relative to input range, (+/-)

0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K

  • â—� Thermocouple, relative to input range, (+/-)

0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K

  • â—� Voltage, relative to output range, (+/-)

0.2 %

  • â—� Current, relative to output range, (+/-)

0.2 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

  • â—� Series mode interference (peak value of interference < rated value of input range), min.

40 dB

  • â—� Common mode voltage, max.

10 V

  • â—� Common mode interference, min.

60 dB

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

No

Interrupts/diagnostics/status information

 

Diagnostics function

Yes

Substitute values connectable

Yes

Alarms

 

  • â—� Diagnostic alarm

Yes

  • â—� Limit value alarm

Yes; two upper and two lower limit values in each case

Diagnostic messages

 

  • â—� Monitoring the supply voltage

Yes

  • â—� Wire-break

Yes; only for input type 1 ... 5 V, 4 ... 20 mA, TC, R, RTD and output type current

  • â—� Short-circuit

Yes; Only for output type "voltage"

  • â—� Overflow/underflow

Yes

Diagnostics indication LED

 

  • â—� RUN LED

Yes; Green LED

  • â—� ERROR LED

Yes; Red LED

  • â—� Monitoring of the supply voltage (PWR-LED)

Yes; Green LED

  • â—� Channel status display

Yes; Green LED

  • â—� for channel diagnostics

Yes; Red LED

  • â—� for module diagnostics

Yes; Red LED

Potential separation

 

Potential separation analog inputs

 

  • â—� between the channels

No

  • â—� between the channels, in groups of

4

  • â—� between the channels and backplane bus

Yes

  • â—� Between the channels and load voltage L+

Yes

Potential separation analog outputs

 

  • â—� between the channels

No

  • â—� between the channels, in groups of

2

  • â—� between the channels and backplane bus

Yes

  • â—� Between the channels and load voltage L+

Yes

Permissible potential difference

 

between the inputs (UCM)

20 V DC

Between the inputs and MANA (UCM)

10 V DC

between S- and MANA (UCM)

8 V DC

Isolation

 

Isolation tested with

707 V DC (type test)

Ambient conditions

 

Ambient temperature during operation

 

  • â—� horizontal installation, min.

0 °C

  • â—� horizontal installation, max.

60 °C

  • â—� vertical installation, min.

0 °C

  • â—� vertical installation, max.

40 °C

Decentralized operation

 

Prioritized startup

No

Dimensions

 

Width

25 mm

Height

147 mm

Depth

129 mm

Weights

 

Weight, approx.

250 g

Other

 

Note:

Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 Ohms (±0.02%); resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermoelement: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K



















  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà