Measured variables | - Flue gas velocity
- Volume flow1)
|
Measuring ranges | - 3 ... 50 m/s
- 0 ... 3 000 000 m3/h
|
Measuring principle | Differential pressure |
Sample gas temperature | Above dew point up to 450 °C standard, others on request |
Sample gas pressure | -50 ... +50 hPa Standard, others on request |
Channel diameter | > 0.5 m |
Ambient temperature | -20 ... +50 °C Standard, others on request |
Degree of protection | IP65 |
Measured value output | 0/4 ... 20 mA, 500 О© |
Digital outputs | 2 relay outputs, load rating 48 V/0.5 A |
Power supply | |
| 24 V DC, 0.5 A |
| 90 ... 264 V AC, 48 … 62 Hz |
Dimensions | |
| |
| 231 x 160 x 105 mm |
| 62 x 90 x 54 mm |
| |
| 24 x 22 x 400 ... 2 000 mm |
| 54 x 50 x 2 000 ... 4 000 mm |
| 100 x 90 x 4 000 ... 8 000 mm |
Weight | 32 kg + 6.8 kg/m probe length Evaluation unit: 1 kg |
Purge-air supply (optional) | 6 ... 8 bar for backflush |