Supply voltage | | | | |
Load voltage L+ | | | | |
| 24V | 24V | 24V; A power supply according to EN 50155 shall be used for railway applications | 24V |
| Yes | Yes | Yes | Yes |
Input current | | | | |
from load voltage L+ (without load), max. | 240mA | 290mA | 135mA | 340mA |
from backplane bus 5 V DC, max. | 60mA | 120mA | 60mA | 100mA |
Power loss | | | | |
Power loss, typ. | 3W | 3W | 3W | 6W |
Analog outputs | | | | |
Number of analog outputs | 4 | 4; Isochronous mode | 2 | 8; 4 @ +70 C |
Voltage output, short-circuit protection | Yes | Yes | Yes | Yes |
Voltage output, short-circuit current, max. | 25mA | 40mA | 25mA | 25mA |
Current output, no-load voltage, max. | 18V | 18V | 18V | 18V |
Output ranges, voltage | | | | |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Output ranges, current | | | | |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Load impedance (in rated range of output) | | | | |
| 1kΩ | 1kΩ | 1kΩ | 1kΩ |
| 1F | 1F | 1F | 1F |
| 500Ω | 500Ω | 500Ω | 500Ω |
| 10mH | 1mH | 10mH | 10mH |
Cable length | | | | |
| 200m | 200m | 200m | 200m |
Analog value generation for the outputs | | | | |
Integration and conversion time/resolution per channel | | | | |
| 12bit; 10 V, 20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit | 16bit | 12bit; 10 V, 20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit | 12bit; 10 V, 20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit |
| 0.8ms | 200s; in isochronous mode 640 s | 0.8ms | 0.8ms |
Settling time | | | | |
| 0.2ms | 0.2ms | 0.2ms | 0.2ms |
| 3.3ms | 3.3ms | 3.3ms | 3.3ms |
| 0.5ms; 0.5 ms (1 mH); 3.3 ms (10 mH) | 0.5ms | 0.5ms; 0.5 ms (1 mH); 3.3 ms (10 mH) | 0.5ms; 0.5 ms (1 mH); 3.3 ms (10 mH) |
Errors/accuracies | | | | |
Operational error limit in overall temperature range | | | | |
| 0.5%; 0.6 % @ < 0 C or > 60 C | 0.12% | 0.5%; 0.6 % @ < 0 C or > 60 C | 0.5%; 0.6 % @ < 0 C or > 60 C |
| 0.6%; 0.7 % @ < 0 C or > 60 C | 0.18% | 0.6%; /-0.7% @ < 0 C or > 60 C | 0.6%; 0.7 % @ < 0 C or > 60 C |
Basic error limit (operational limit at 25 C) | | | | |
| 0.4% | 0.02% | 0.4% | 0.4% |
| 0.5% | 0.02% | 0.5% | 0.5% |
Interrupts/diagnostics/status information | | | | |
Diagnostic functions | Yes; Parameterizable | | Yes; Parameterizable | Yes; Parameterizable |
Substitute values connectable | Yes; Parameterizable | Yes; Parameterizable | Yes; Parameterizable | Yes; Parameterizable |
Alarms | | | | |
| Yes; Parameterizable | Yes | Yes; Parameterizable | Yes; Parameterizable |
Diagnostic messages | | | | |
| Yes | | Yes | Yes |
Diagnostics indication LED | | | | |
| Yes | Yes | Yes | Yes |
Potential separation | | | | |
Potential separation analog outputs | | | | |
| Yes | Yes | Yes | Yes |
Isolation | | | | |
Isolation tested with | 500 V DC | 1500 V DC | 500 V DC | 500 V DC |
Standards, approvals, certificates | | | | |
CE mark | Yes | Yes | Yes | Yes |
UL approval | Yes; File E239877 | Yes; File E239877 | Yes; File E239877 | Yes; File E239877 |
FM approval | Yes; CofC 3028431 | Yes | Yes; CofC 3028431 | Yes; CofC 3028431 |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes |
KC approval | Yes | Yes | Yes | Yes |
EAC (formerly Gost-R) | Yes | Yes | Yes | Yes |
Railway application | | | | |
| No | | No | No |
| No | | Yes; T1 Category 1 Class A/B horizontal mounting position | No |
Ambient conditions | | | | |
Ambient temperature during operation | | | | |
| -25C; = Tmin | 0C; = Tmin | -25C; = Tmin | -25C |
| 70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use | 60C; = Tmax | 70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies | 70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use |
Ambient temperature during storage/transportation | | | | |
| -40C | -40C | -40C | -40C |
| 70C | 70C | 70C | 70C |
Altitude during operation relating to sea level | | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | | |
| 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | | | | |
Use in stationary industrial systems | | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Connection method | | | | |
required front connector | 20-pin | 20-pin | 20-pin | 40-pin |
Dimensions | | | | |
Width | 40mm | 40mm | 40mm | 40mm |
Height | 125mm | 125mm | 125mm | 125mm |
Depth | 120mm | 120mm | 120mm | 120mm |
Weights | | | | |
Weight, approx. | 220g | 220g | 220g | 272g |