Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6AG1322-1BF01-2XB0

6AG1322-8BF00-2AB0

6AG1322-1BH01-2AA0

6AG1322-1BL00-2AA0

SIPLUS S7-300 SM322 8DO/24VDC 2A

SIPLUS SM322 8DA/24VDC

SIPLUS S7-300 SM322 16DA/24VDC 0.5A

SIPLUS S7-300 SM322 32DO/24VDC 0.5A

Supply voltage

Load voltage L+

  • Rated value (DC)

24V

24V

24V

24V

  • permissible range, lower limit (DC)

20.4V

20.4V

20.4V

20.4V

  • permissible range, upper limit (DC)

28.8V

28.8V

28.8V

28.8V

Input current

from load voltage L+ (without load), max.

60mA

90mA

80mA

160mA

from backplane bus 5 V DC, max.

40mA

70mA

80mA

110mA

Power loss

Power loss, typ.

6.8W

5W

4.9W

6.6W

Digital outputs

Number of digital outputs

8

8

16

32

Limitation of inductive shutdown voltage to

L+ (-48 V)

L+ (-45 V)

L+ (-53 V)

L+ (-53 V)

Switching capacity of the outputs

  • on lamp load, max.

10W

5W

5W

5W

Load resistance range

  • lower limit

12Ω

48Ω

48Ω

48Ω

  • upper limit

4kΩ

3kΩ

4kΩ

4kΩ

Output voltage

  • for signal "1", min.

L+ (-0.8 V)

L+ (-0.8 to -1.6 V)

L+ (-0.8 V)

L+ (-0.8 V)

Output current

  • for signal "1" rated value

2A

0.5A

0.5A

0.5A

  • for signal "1" minimum load current

5mA

10mA

5mA

5mA

  • for signal "0" residual current, max.

0.5mA

0.5mA

0.5mA

0.5mA

Switching frequency

  • with resistive load, max.

100Hz

100Hz

100Hz

100Hz

  • with inductive load, max.

0.5Hz

2Hz

0.5Hz

  • on lamp load, max.

10Hz

10Hz

10Hz

10Hz

Total current of the outputs (per group)

horizontal installation

  • up to 40 C, max.

4A

4A

4A

  • up to 60 C, max.

4A

3A

3A

3A

  • up to 70 C, max.

4A

2.5A; (without diode) & 1.5 A (with diode)

3A

2A

vertical installation

  • up to 40 C, max.

4A

4A

2A

2A

Cable length

  • shielded, max.

1000m

1000m

1000m

1000m

  • unshielded, max.

600m

600m

600m

600m

Interrupts/diagnostics/status information

Diagnostic functions

No

Yes; Parameterizable

No

No

Alarms

  • Diagnostic alarm

No

Yes; Parameterizable

No

No

Diagnostic messages

  • Wire-break

No

Yes

No

No

  • Short-circuit

No

Yes

No

No

  • Fuse blown

No

No

No

  • missing load voltage

No

Yes

No

No

Diagnostics indication LED

  • Rated load voltage PWR (green)

No

No

No

No

  • Fuse OK FSG (green)

No

No

No

No

  • Group error SF (red)

Yes

No

  • Status indicator digital output (green)

Yes; per channel

Yes; per channel

Yes

Yes; per channel

  • Channel fault indicator F (red)

Yes

No

Potential separation

Potential separation digital outputs

  • between the channels

Yes

Yes

Yes

  • between the channels, in groups of

4

8

8

8

  • between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Permissible potential difference

between different circuits

75 V DC/60 V AC

75 V DC/60 V AC

75 V DC/60 V AC

75 V DC/60 V AC

Isolation

Isolation tested with

500 V DC

500 V DC

500 V DC

500 V DC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes

Yes; CofC 3028431

Yes; CofC 3028431

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Railway application

  • EN 50121-4

No

  • EN 50155

No

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Ambient conditions

Ambient temperature during operation

  • min.

-25C

-25C; = Tmin

-25C

-25C; = Tmin

  • max.

70C; = Tmax; 60 C @ UL/cUL use

70C; = Tmax; 60 C @ UL/cUL use

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

  • max.

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

20-pin

20-pin

20-pin

40-pin

Dimensions

Width

40mm

40mm

40mm

40mm

Height

125mm

125mm

125mm

125mm

Depth

120mm

120mm

120mm

120mm

Weights

Weight, approx.

190g

210g

190g

260g


Article number

6AG1322-1CF00-7AA0

6AG1322-1HF10-2AA0

6AG1322-5HF00-4AB0

6AG1322-1FF01-7AA0

SIPLUS SM322 8DA/48-125VDC

SIPLUS SM322 8DA - Relais

SIPLUS_SM322_8RO

SIPLUS S7-300 SM322 8DA/120/230VAC

Supply voltage

Load voltage L+

  • Rated value (DC)

48V; 48 V DC to 125 V DC

120V

24V

  • permissible range, lower limit (DC)

40V

24V

  • permissible range, upper limit (DC)

140V

120V

Load voltage L1

  • Rated value (AC)

230V

230V

230V; 120/230 V AC

  • permissible range, lower limit (AC)

93V

  • permissible range, upper limit (AC)

264V

Input current

from supply voltage L+, max.

125mA

160mA

from load voltage L+ (without load), max.

2mA

from load voltage L1 (without load), max.

2mA

from backplane bus 5 V DC, max.

100mA

40mA

100mA

100mA

Power loss

Power loss, typ.

7.2W

4.2W

3.5W

8.6W

Digital outputs

Number of digital outputs

8

8; Relays

8; Relays

8

Limitation of inductive shutdown voltage to

M (-1 V)

Switching capacity of the outputs

  • on lamp load, max.

15W; 15 W (48 V) or 40 W (125 V)

1500W; 230 V AC

1500W; 230 V AC

50W

Output voltage

  • for signal "1", min.

L+ (-1.2 V)

L1 (-1.5 V)

Output current

  • for signal "1" rated value

1.5A

5A

5A

2A

  • for signal "1" minimum load current

10mA

5mA

10mA

10mA

  • for signal "1" permissible surge current, max.

3A; for 10 ms

20A; max. 1 AC cycle

  • for signal "0" residual current, max.

0.5mA

2mA

Switching frequency

  • with resistive load, max.

25Hz

2Hz

2Hz

10Hz

  • with inductive load, max.

0.5Hz

0.5Hz

0.5Hz

0.5Hz

  • on lamp load, max.

10Hz

2Hz

2Hz

1Hz

  • mechanical, max.

10Hz

10Hz

Total current of the outputs (per group)

horizontal installation

  • up to 40 C, max.

6A

4A

  • up to 60 C, max.

3A

5A

5A

2A

  • up to 70 C, max.

1A

5A

1.5A

vertical installation

  • up to 40 C, max.

4A

5A

5A

2A

Relay outputs

  • Rated supply voltage of relay coil L+ (DC)

24V

  • Number of operating cycles, max.

300000; 300000 (24 V DC, at 2 A); 200000 (120 V AC, at 3 A); 100000 (230 V AC, at 3 A)

100000; 100000 (24 V DC, at 5 A), 100000 (230 V AC, at 5 A)

Switching capacity of contacts

  • with inductive load, max.

3A; 3 A (230 V DC), 2 A (24 V AC)

5A; 5 A (230 V DC), 5 A (24 V AC)

  • with resistive load, max.

8A; 8 A (230 V DC), 5 A (24 V AC)

5A; 5 A (230 V DC), 5 A (24 V AC)

Cable length

  • shielded, max.

1000m

1000m

1000m

1000m

  • unshielded, max.

600m

600m

600m

600m

Interrupts/diagnostics/status information

Diagnostic functions

No

No

Yes; Parameterizable

Yes; Fuse blown or load voltage missing

Alarms

  • Diagnostic alarm

No

No

Yes; Parameterizable

No

Diagnostic messages

  • Wire-break

No

No

No

  • Short-circuit

No

No

No

  • Fuse blown

No

No

Yes

  • missing load voltage

No

No

Yes

Diagnostics indication LED

  • Rated load voltage PWR (green)

No

No

Yes

  • Fuse OK FSG (green)

No

No

Yes

  • Group error SF (red)

Yes

Yes

Yes

  • Status indicator digital output (green)

Yes

Yes

Yes

Yes

Potential separation

Potential separation digital outputs

  • between the channels

Yes

Yes

Yes

Yes

  • between the channels, in groups of

4

1

1

4

  • between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Permissible potential difference

between different circuits

146 V DC/132 V AC

Isolation

Isolation tested with

1500 V AC

2000 V AC

1500 V AC

1500 V AC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes; CofC 3028431

Yes; CofC 3028431

Yes; CofC 3028431

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Yes

Railway application

  • EN 50155

Yes; T1 Category 1 Class A/B horizontal mounting position

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Yes; T1 Category 1 Class A/B horizontal mounting position

Ambient conditions

Ambient temperature during operation

  • min.

-25C

-25C

0C; = Tmin

-40C

  • max.

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

60C

60C; = Tmax

70C; = Tmax; for use on railway vehicles according to EN 50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/UL hazardous use applies

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

-40C

  • max.

70C

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

20-pin

40-pin

40-pin

20-pin

Dimensions

Width

40mm

40mm

40mm

40mm

Height

125mm

125mm

125mm

125mm

Depth

120mm

120mm

120mm

120mm

Weights

Weight, approx.

250g

320g

320g

275g


Article number

6AG1322-5FF00-4AB0

6AG1322-1FH00-7AA0

6AG1322-1HH01-2AA0

SIPLUS S7-300 SM322 8DO

SIPLUS S7-300 SM322 16DO

SIPLUS SM322

Supply voltage

Load voltage L+

  • Rated value (DC)

120V

Load voltage L1

  • Rated value (AC)

230V; 120/230 V AC

230V; 120/230 V AC

230V

  • permissible range, lower limit (AC)

79V

79V

  • permissible range, upper limit (AC)

264V

264V

Input current

from supply voltage L+, max.

250mA

from load voltage L1 (without load), max.

2mA

2mA

from backplane bus 5 V DC, max.

100mA

200mA

100mA

Power loss

Power loss, typ.

8.6W

8.6W

4.5W

Digital outputs

Number of digital outputs

8

16

16; Relays

Switching capacity of the outputs

  • on lamp load, max.

50W

50W

50W; 230 V AC

Output voltage

  • for signal "1", min.

L1 (-8.5 V)

Output current

  • for signal "1" rated value

2A

1A

2A

  • for signal "1" minimum load current

10mA

10mA

10mA

  • for signal "1" permissible surge current, max.

20A; with 2 half waves

20A; with 2 half waves

  • for signal "0" residual current, max.

2mA

2mA

Switching frequency

  • with resistive load, max.

10Hz

10Hz

1Hz

  • with inductive load, max.

0.5Hz

0.5Hz

0.5Hz

  • on lamp load, max.

1Hz

1Hz

1Hz

  • mechanical, max.

10Hz

Total current of the outputs (per group)

horizontal installation

  • up to 40 C, max.

8A

4A

  • up to 60 C, max.

4A

2A

8A

  • up to 70 C, max.

1A

vertical installation

  • up to 40 C, max.

4A

2A

8A

Relay outputs

  • Rated supply voltage of relay coil L+ (DC)

24V

  • Number of operating cycles, max.

100000; 50000 (24 V DC, at 2 A); 700000 (120 V AC, at 2 A); 100000 (230 V AC, at 2 A)

Switching capacity of contacts

  • with inductive load, max.

2A; 2 A (230 V AC), 2 A (24 V DC)

  • with resistive load, max.

2A; 2 A (230 V AC), 2 A (24 V DC)

Cable length

  • shielded, max.

1000m

1000m

1000m

  • unshielded, max.

600m

600m

600m

Interrupts/diagnostics/status information

Diagnostic functions

Yes; Parameterizable

Yes; Fuse blown or load voltage missing

No

Alarms

  • Diagnostic alarm

Yes; Parameterizable

No

No

Diagnostic messages

  • Wire-break

No

No

  • Short-circuit

No

No

  • Fuse blown

Yes

No

  • missing load voltage

No

No

Diagnostics indication LED

  • Rated load voltage PWR (green)

No

No

  • Fuse OK FSG (green)

Yes; Red LED for fuse

No

  • Group error SF (red)

Yes

Yes

  • Status indicator digital output (green)

Yes

Yes

Yes

Potential separation

Potential separation digital outputs

  • between the channels

Yes

Yes

  • between the channels, in groups of

1

8

8

  • between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Yes; Optocoupler

Isolation

Isolation tested with

1500 V AC

4 000 V DC

1500 V AC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes; CofC 3028431

Yes; CofC 3028431

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Railway application

  • EN 50121-4

No

  • EN 50155

No

No

Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B

Ambient conditions

Ambient temperature during operation

  • min.

0C; = Tmin

-40C; = Tmin

-40C

  • max.

60C; = Tmax

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

  • max.

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

40-pin

20-pin

20-pin

Dimensions

Width

40mm

40mm

40mm

Height

125mm

125mm

125mm

Depth

120mm

120mm

120mm

Weights

Weight, approx.

275g

275g

250g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS -

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK -
2018
Siemens Industry Catalog Drive technology Automation technology Automation systems SIMATIC Industrial Automation Systems Controllers I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP SIMATIC ET 200MP SIMATIC ET 200S SIMATIC ET 200M Interface modules SIPLUS Interface modules I/O modules Digital modules SM 321 digital input modules SM 322 digital output modules SM 323/SM 327 digital input/output modules SIPLUS S7-300 digital modules SIPLUS S7-300 SM 321 SIPLUS S7-300 SM 322 SIPLUS S7-300 SM 323 Analog modules Analog modules with HART F digital/analog modules Ex digital modules Ex analog modules Function modules Special modules Communication Connection system Power supplies SIMATIC ET 200iSP SIMATIC ET 200 systems without control cabinet IO systems for heating elements PROFIBUS components PROFINET components Network components for PROFIBUS Network transitions SIMATIC control systems Software for SIMATIC Controllers Programming devices Siemens Partner Programm SIMOTION Motion Control System SINUMERIK CNC automation systems System cabling/control cabinets Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.