Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6AG1540-1AD00-7AA0

6AG1541-1AD00-7AB0

6AG1540-1AB00-7AA0

6AG1541-1AB00-7AB0

SIPLUS S7-1500 CM PTP RS232 BA

SIPLUS S7-1500 CM PTP RS232 HF

SIPLUS S7-1500 CM PTP RS422/485 BA

SIPLUS S7-1500 CM PTP RS422/485 HF

General information

Product type designation

CM PtP RS232 BA

CM PtP RS232 HF

CM PtP RS422/485 BA

CM PtP RS422/485 HF

Product function

  • I&M data

Yes; I&M 0

Yes; I&M 0

Yes; I&M 0

Yes; I&M 0

Installation type/mounting

Rail mounting

Yes; S7-1500 mounting rail

Yes; S7-1500 mounting rail

Yes; S7-1500 mounting rail

Yes; S7-1500 mounting rail

Supply voltage

Type of supply voltage

system power supply

system power supply

system power supply

system power supply

Input current

Current consumption (rated value)

35mA; From the backplane bus

35mA; From the backplane bus

33mA; From the backplane bus

33mA; From the backplane bus

Power

Power available from the backplane bus

0.65W

0.65W

0.65W

0.65W

Power loss

Power loss, typ.

0.6W

0.6W

0.6W

0.6W

Address area

Occupied address area

  • Inputs

8byte

8byte

8byte

8byte

Interface types

RS 232

  • Transmission rate, max.

19.2kbit/s

115.2kbit/s

  • Cable length, max.

15m

15m

  • RS 232 auxiliary signals

RTS, CTS, DTR, DSR, RI, DCD

RTS, CTS, DTR, DSR, RI, DCD

RS 485

  • Transmission rate, max.

19.2kbit/s

115.2kbit/s

  • Cable length, max.

1200m

1200m

RS 422

  • Transmission rate, max.

19.2kbit/s

115.2kbit/s

  • Cable length, max.

1200m

1200m

  • 4-wire full duplex connection

Yes

Yes

  • 4-wire multipoint connection

No

No

Integrated protocols

Freeport

  • Telegram length, max.

1kbyte

4kbyte

1kbyte

4kbyte

  • Bits per character

7 or 8

7 or 8

7 or 8

7 or 8

  • Number of stop bits

1 or 2 bit

1 or 2 bit

1 or 2 bit

1 or 2 bit

  • Parity

None, even, odd, always 1, always 0, any

None, even, odd, always 1, always 0, any

None, even, odd, always 1, always 0, any

None, even, odd, always 1, always 0, any

3964 (R)

  • Telegram length, max.

1kbyte

4kbyte

1kbyte

4kbyte

  • Bits per character

7 or 8

7 or 8

7 or 8

7 or 8

  • Number of stop bits

1 or 2 bit

1 or 2 bit

1 or 2 bit

1 or 2 bit

  • Parity

None, even, odd, always 1, always 0, any

None, even, odd, always 1, always 0, any

None, even, odd, always 1, always 0, any

None, even, odd, always 1, always 0, any

Modbus RTU master

  • Address area

1 to 247, extended 1 to 65535

1 to 247, extended 1 to 65535

  • Number of slaves, max.

1

32

MODBUS RTU slave

  • Address area

1 to 247, extended 1 to 65535

1 to 247, extended 1 to 65535

Telegram buffer

  • Buffer memory for telegrams

2kbyte

8kbyte

2kbyte

8kbyte

  • Number of telegrams which can be buffered

255

255

255

255

Interrupts/diagnostics/status information

Diagnostics function

Yes

Yes

Yes

Yes

Alarms

  • Diagnostic alarm

Yes

Yes

Yes

Yes

  • Hardware interrupt

No

No

No

No

Diagnostic messages

  • Wire-break

Yes

Yes

Yes

Yes

Diagnostics indication LED

  • RUN LED

Yes; Green LED

Yes

Yes; Green LED

Yes; Green LED

  • Receive RxD

Yes; yellow LED

Yes; yellow LED

Yes; yellow LED

Yes; yellow LED

  • Transmit TxD

Yes; yellow LED

Yes; yellow LED

Yes; yellow LED

Yes; yellow LED

Potential separation

between backplane bus and interface

Yes

Yes

Yes

Yes

Isolation

Isolation tested with

500 V

500 V

500 V

500 V

Ambient conditions

Ambient temperature during operation

  • horizontal installation, min.

-40C; = Tmin; Startup @ -25 C

-40C; = Tmin; Startup @ -25 C

-40C; = Tmin; Startup @ -25 C

-40C; = Tmin; Startup @ -25 C

  • horizontal installation, max.

70C

70C

70C

70C

  • vertical installation, min.

-40C; = Tmin; Startup @ -25 C

-40C; = Tmin; Startup @ -25 C

-40C; = Tmin; Startup @ -25 C

-40C; = Tmin; Startup @ -25 C

  • vertical installation, max.

40C

40C

40C

40C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Decentralized operation

to SIMATIC S7-300

Yes

Yes

Yes

Yes

to SIMATIC S7-400

Yes

Yes

Yes

Yes

to SIMATIC S7-1500

Yes

Yes

Yes

Yes

to standard PROFINET controller

Yes

Yes

Yes

Yes

Fast Startup supported

Yes

Yes

Yes

Yes

Dimensions

Width

35mm

35mm

35mm

35mm

Height

147mm

147mm

147mm

147mm

Depth

127mm

127mm

127mm

127mm

Weights

Weight, approx.

0.22kg

0.22kg

0.22kg

0.22kg



















  © " " 2007-2022