Article number

6GK5812-1AA00-2AA2

6GK5812-1BA00-2AA2

6GK5816-1AA00-2AA2

6GK5816-1BA00-2AA2

Transmission rate

Transfer rate

10Mbit/s,100Mbit/s

10Mbit/s,100Mbit/s

10Mbit/s,100Mbit/s

10Mbit/s,100Mbit/s

Transfer rate

  • for ADSL2+ transmission with downlink maximum

25Mbit/s

25Mbit/s

25Mbit/s

25Mbit/s

  • for ADSL2+ transmission with uplink maximum

1.4Mbit/s

1.4Mbit/s

1.4Mbit/s

1.4Mbit/s

Interfaces

Number of electrical connections

  • for internal network

1

1

4

4

  • for external network

1

1

1

1

  • for power supply

2

2

2

2

Type of electrical connection

  • for internal network

RJ45 port (10/100 Mbit/s, TP, autocrossover)

RJ45 port (10/100 Mbit/s, TP, autocrossover)

RJ45 port (10/100 Mbit/s, TP, autocrossover)

RJ45 port (10/100 Mbit/s, TP, autocrossover)

  • for external network

RJ45 DSL Port

RJ45 DSL Port

RJ45 DSL Port

RJ45 DSL Port

  • for power supply

Terminal strip

Terminal strip

Terminal strip

Terminal strip

Signal-Inputs/outputs

Number of electrical connections

  • for digital input signals

1

1

1

1

  • for digital output signals

1

1

1

1

Type of electrical connection

  • for digital input signals

Terminal block

Terminal block

Terminal block

Terminal block

  • for digital output signals

Terminal block

Terminal block

Terminal block

Terminal block

WAN connection

Type of WAN connection is supported

ADSL,ADSL2,ADSL2+

ADSL,ADSL2,ADSL2+

ADSL,ADSL2,ADSL2+

ADSL,ADSL2,ADSL2+

Operating mode for ADSL2/ADSL2+ is supported

Annex A

Annex B,Annex J

Annex A

Annex B,Annex J

Supply voltage, current consumption, power loss

Supply voltage Rated value

24V

24V

24V

24V

Supply voltage rated value

10.8...28.8

10.8...28.8

10.8...28.8

10.8...28.8

Type of voltage of the supply voltage

DC

DC

DC

DC

Consumed current at rated supply voltage maximum

320mA

320mA

330mA

330mA

Power loss [W]

  • maximum

8W

8W

8W

8W

Permitted ambient conditions

Ambient temperature

  • during operation

0...60C

0...60C

0...60C

0...60C

  • during storage

-40...+70C

-40...+70C

-40...+70C

-40...+70C

Relative humidity at 25 C during operation maximum

95%

95%

95%

95%

Protection class IP

IP20

IP20

IP20

IP20

Design, dimensions and weight

Design

compact

compact

compact

compact

Depth

127mm

127mm

127mm

127mm

Height

147mm

147mm

147mm

147mm

Width

35mm

35mm

35mm

35mm

Net weight

0.4kg

0.4kg

0.4kg

0.4kg

Mounting type

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

  • S7-1500 rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

Product properties, functions, components general

Product function

  • Dynamic DNS

Yes

Yes

Yes

Yes

  • no-ip.com client

Yes

Yes

Yes

Yes

Product functions management, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

Type of configuration

Web-based management

Web-based management

Web-based management

Web-based management

Product functions Diagnosis

Protocol is supported

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v2c

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

Product function

  • Statistics Packet Size

No

No

No

No

  • Statistics packet type

No

No

No

No

  • Error statistics

No

No

No

No

  • SysLog

Yes

Yes

Yes

Yes

  • Packet Filter Log

Yes

Yes

Yes

Yes

Product functions DHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP server - internal network

Yes

Yes

Yes

Yes

Product functions Routing

Router function

  • NAT (IP masquerading)

Yes

Yes

Yes

Yes

  • Port forwarding

Yes

Yes

Yes

Yes

  • NAT traversal

Yes

Yes

Yes

Yes

  • 1:1 NAT

Yes

Yes

Yes

Yes

  • DNS cache

Yes

Yes

Yes

Yes

Product functions Security

Suitability for operation Virtual Private Network

Yes

Yes

Yes

Yes

Firewall version

Statefull Inspection

Statefull Inspection

Statefull Inspection

Statefull Inspection

Product function

  • Password protection

Yes

Yes

Yes

Yes

  • packet filter

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

No

No

No

No

Product function

  • broadcast blocking

No

No

No

No

  • with VPN connection

IPsec, OpenVPN (as Client)

IPsec, OpenVPN (as Client)

IPsec, OpenVPN (as Client)

IPsec, OpenVPN (as Client)

Number of possible connections with VPN connection

20

20

20

20

Type of authentication with Virtual Private Network PSK

Yes

Yes

Yes

Yes

Protocol is supported

  • IPsec tunnel and transport mode

Yes

Yes

Yes

Yes

Key length

  • 1 with IPsec AES with Virtual Private Network

128bit

128bit

128bit

128bit

  • 2 with IPsec AES with Virtual Private Network

192bit

192bit

192bit

192bit

  • 3 with IPsec AES with Virtual Private Network

256bit

256bit

256bit

256bit

  • with IPsec 3DES with Virtual Private Network

168bit

168bit

168bit

168bit

Type of Internet key exchange with Virtual Private Network

  • main mode

Yes

Yes

Yes

Yes

  • quick mode

Yes

Yes

Yes

Yes

Type of packet authentication with Virtual Private Network

MD5, SHA-1, SHA-256, SHA-384, SHA-512

MD5, SHA-1, SHA-256, SHA-384, SHA-512

MD5, SHA-1, SHA-256, SHA-384, SHA-512

MD5, SHA-1, SHA-256, SHA-384, SHA-512

IETF profile with Virtual Private Network X.509v3 certificate

Yes

Yes

Yes

Yes

Product functions Time

Protocol is supported

  • NTP

Yes

Yes

Yes

Yes

  • SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC

EN 55022, EN 55024

EN 55022, EN 55024

EN 55022, EN 55024

EN 55022, EN 55024

  • for FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15, EN 60079-0, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X

EN 60079-15, EN 60079-0, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X

EN 60079-15:2010, EN 60079-0:2009, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X

EN 60079-15, EN 60079-0, II 3 G Ex nA IIC T4 Gc, KEMA 07ATEX0145 X

  • for safety from CSA and UL

UL E115352 Vol. X2

UL E115352 Vol. X2

UL E115352 Vol. X2

UL E115352 Vol. X2

  • for hazardous zone from CSA and UL

ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC

ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC

ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC

ANSI/ISA 12.12.01-2013, CAN/CSA C22.2 No.213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC

  • for emitted interference

EN 55022 Class A

EN 55022 Class A

EN 55022 Class A

EN 55022 Class A

  • for interference immunity

EN 55024

EN 55024

EN 55024

EN 55024

Certificate of suitability

  • CE marking

Yes

Yes

Yes

Yes

MTBF at 40 C

38y

38y

38y

38y



















  © " " 2007-2022