Vibratory load | |
- Transport 1) acc. to EN 60721-3-2
| |
- Control Units and Power Modules
| Class 2M3 |
- Operation
Test values acc. to EN 60068‑2‑6
| Test Fc |
| 10 ... 58 Hz: Constant deflection 0.075 mm 58 ... 150 Hz: Constant acceleration = 9.81 m/s2 (1 Г— g) |
Shock load | |
- Transport 1) acc. to EN 60721-3-2
| |
- Control Units and Power Modules
| Class 2M3 |
- Operation
Test values acc. to EN 60068‑2‑27
| Test Ea |
- Power Modules frame sizes FSA and FSB
| 147 m/s2 (15 Г— g)/11 ms |
- Power Modules frame sizes FSC to FSF
| - 49 m/s2 (5 Г— g)/30 ms |
Ambient conditions | |
- Protection class according to EN 61800‑5‑1
| Class I (with protective conductor system) and Class III (PELV) |
| DIN VDE 0106 Part 100 and BGV A 3 when used properly |
| Internal ventilator, power units with increased air cooling by built-in fans |
Permissible ambient/coolant temperature (air) during operation | |
| 0 ... 40 °C (32 ... 104 °F) without derating, > 40 ... 55 °C (>104 ... 131 °F), see derating characteristics |
- Control Units, supplementary system components, DC link components and Sensor Modules
| 0 … 55 °C (32 … 131 °F) up to 2000 m (6562 ft) above sea level |
Climatic ambient conditions | |
- Storage 1) acc. to EN 60721‑3‑1
| Class 1K4 Temperature -25 ... +70 °C (-13 ... 158 °F) |
- Transport 1) acc. to EN 60721-3-2
| Class 2K4 Temperature -40 ... +70 °C (-40 ... 158 °F) max. Air humidity 95% at 40 °C (104 °F) |
- Operation acc. to EN 60721‑3‑3
| Class 3K3 Temperature 0 ... 55 °C (32 ... 131 °F) Condensation, splashwater and ice formation are not permitted (EN 60204, Part 1) |
Environmental class/harmful chemical substances | |
- Storage 1) acc. to EN 60721‑3‑1
| Class 1C2 |
- Transport 1) acc. to EN 60721-3-2
| Class 2C2 |
- Operation acc. to EN 60721‑3‑3
| Class 3C2 |
Organic/biological influences | |
- Storage 1) acc. to EN 60721‑3‑1
| Class 1B1 |
- Transport 1) acc. to EN 60721-3-2
| Class 2B1 |
- Operation acc. to EN 60721‑3‑3
| Class 3B1 |
Degree of pollution According to EN 61800‑5‑1 | 2 |