General information | | | | |
Product type designation | DI 16x24VDC HF | DI 32x24VDC HF | DI 16x24VDC SRC BA | DI 16x230VAC BA |
HW functional status | E01 | E01 | | |
Firmware version | V1.0.0 | V1.0.0 | | |
Product function | | | | |
| Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
Engineering with | | | | |
| V12 / V12 | V12 / V12 | | |
| V5.5 SP3 / - | V5.5 SP3 / - | | |
Supply voltage | | | | |
Rated value (DC) | 24 V | 24 V | 24 V | |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | |
Reverse polarity protection | Yes | Yes | | |
Input current | | | | |
Current consumption, max. | 20 mA; with 24 V DC supply | 40 mA; 20 mA per group with 24 V DC supply | | |
Power | | | | |
Power available from the backplane bus | 1.1 W | 1.1 W | 0.9 W | 1 W |
Power loss | | | | |
Power loss, typ. | 2.6 W | 4.2 W | 2.8 W | 4.9 W |
Digital inputs | | | | |
Number of digital inputs | 16 | 32; > +60 °C, number of simultaneously controllable inputs max. 16 | 16; > +60 °C, number of simultaneously controllable inputs max. 8 | 16; > +60 °C, number of simultaneously controllable inputs max. 8 |
Source/sink input | P-reading | P-reading | Yes; m-reading | |
Input characteristic curve in accordance with IEC 61131, type 1 | | | | Yes |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes | Yes | Yes | |
Input voltage | | | | |
| DC | DC | DC | AC |
| 24 V | 24 V | 24 V | |
| | | | 230 V; 120/230 V AC (47 Hz to 63 Hz) |
| -30 to +5V | -30 to +5V | -5 to +30V | 0V AC to 40V AC |
| +11 to +30V | +11 to +30V | -11 to -30V | 79V AC to 264V AC |
Input current | | | | |
| 2.5 mA | 2.5 mA | 4.5 mA | 11 mA; At 230 V AC/50 Hz and 6.5 mA at 120 V AC/50 Hz |
Input delay (for rated value of input voltage) | | | | |
for standard inputs | | | | |
| Yes; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms | Yes; 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms | No | No |
| 0.05 ms | 0.05 ms | 3 ms | |
| 20 ms | 20 ms | 4 ms | 25 ms |
| 0.05 ms | 0.05 ms | 3 ms | |
| 20 ms | 20 ms | 4 ms | 25 ms |
for interrupt inputs | | | | |
| Yes | Yes | No | No |
Cable length | | | | |
| 1 000 m | 1 000 m | 1 000 m | 1 000 m |
| 600 m | 600 m | 600 m | 600 m |
Encoder | | | | |
Connectable encoders | | | | |
| Yes | Yes | Yes | Yes |
| 1.5 mA | 1.5 mA | 1.5 mA | 2 mA |
Isochronous mode | | | | |
Isochronous operation (application synchronized up to terminal) | Yes | Yes | No | No |
Filtering and processing time (TCI), min. | 80 µs; At 50 Ојs filter time | 80 µs; At 50 Ојs filter time | | |
Bus cycle time (TDP), min. | 250 µs | 250 µs | | |
Interrupts/diagnostics/status information | | | | |
Diagnostics function | Yes | Yes | No | |
Alarms | | | | |
| Yes | Yes | No | No |
| Yes | Yes | No | No |
Diagnostic messages | | | | |
| Yes | Yes | No | No |
| Yes; to I < 350 µA | Yes; to I < 350 µA | No | No |
| No | No | No | No |
| No | No | No | No |
Diagnostics indication LED | | | | |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED |
| Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED |
| Yes; Green LED | Yes; Green LED | No | No |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED |
| Yes; Red LED | Yes; Red LED | No | No |
| Yes; Red LED | Yes; Red LED | No | Yes; Red LED |
Potential separation | | | | |
Potential separation channels | | | | |
| No | Yes | No | No |
| 16 | 16 | 16 | 4 |
| Yes | Yes | Yes | Yes |
| No | No | | |
Permissible potential difference | | | | |
between different circuits | 75 V DC/60 V AC (base isolation) | 75 V DC/60 V AC (base isolation) | 75 V DC/60 V AC | 250 V AC between the channels and the backplane bus; 500 V AC between the channels |
Isolation | | | | |
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 2500 V DC |
Ambient conditions | | | | |
Ambient temperature during operation | | | | |
| -40 °C; = Tmin | -40 °C; = Tmin | -40 °C; = Tmin | -40 °C; = Tmin |
| 70 °C; = Tmax | 70 °C; = Tmax; > +60 °C number of simultaneously controllable inputs max. 16 | 70 °C; = Tmax; > +60 °C number of simultaneously controllable inputs max. 8 | 70 °C; = Tmax; > +60 °C number of simultaneously controllable inputs max. 8 |
| -40 °C; = Tmin | -40 °C; = Tmin | -40 °C; = Tmin | -40 °C; = Tmin |
| 40 °C; = Tmax | 40 °C; = Tmax | 40 °C; = Tmax | 40 °C; = Tmax |
Altitude during operation relating to sea level | | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) |
Relative humidity | | | | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Use in stationary industrial systems | | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Decentralized operation | | | | |
Fast Startup supported | Yes; 500 ms | Yes; 500 ms | Yes; 500 ms | Yes; 500 ms |
Dimensions | | | | |
Width | 35 mm | 35 mm | 35 mm | 35 mm |
Height | 147 mm | 147 mm | 147 mm | 147 mm |
Depth | 129 mm | 129 mm | 129 mm | 129 mm |
Weights | | | | |
Weight, approx. | 240 g | 260 g | 230 g | 200 g |