General information | | | | | | |
Product type designation | IM 155-6 PN BA | IM 155-6 PN ST | IM 155-6 PN ST | IM 155-6 PN HF | IM 155-6 PN HS | IM 155-6 DP HF |
HW functional status | | FS01 | | | | |
Firmware version | V3.2 | V4.1 | V3.3 | V3.3 | V4.0 | V3.1 |
Product function | | | | | | |
| Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M4 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
| Yes; Single hot swapping | Yes; Single hot swapping | Yes; Single hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping |
Engineering with | | | | | | |
| V13 SP1 | V14 | V13 SP1 | V13 SP1 Update 6 | STEP 7 V14 or higher | V13 SP1 |
| V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher |
| | | | | | One GSD file each, Revision 3 and 5 and higher |
| V2.3 / - | V2.3 / - | V2.3 / - | - / V2.3 | - / V2.3 | |
Configuration control | | | | | | |
via dataset | Yes | Yes | Yes | Yes | Yes | Yes |
Supply voltage | | | | | | |
Type of supply voltage | | | | | | DC |
Rated value (DC) | 24V | 24V | 24V | 24V | 24V | 24V |
permissible range, lower limit (DC) | 19.2V | 19.2V | 19.2V | 19.2V | 19.2V | 19.2V |
permissible range, upper limit (DC) | 28.8V | 28.8V | 28.8V | 28.8V | 28.8V | 28.8V |
Reverse polarity protection | Yes | Yes | Yes | Yes | Yes | Yes |
Short-circuit protection | | Yes | | | | |
Mains buffering | | | | | | |
| 5ms | 10ms | 5ms | 5ms | 5ms | 5ms |
Input current | | | | | | |
Current consumption (rated value) | | 450mA | | | | |
Current consumption, max. | 300mA | 550mA | 450mA | 700mA | 500mA | 250mA |
Inrush current, max. | | 3.7A | 3.7A | 4.5A | 4.5A | 4.5A |
It | 0.09As | 0.09As | 0.09As | 0.09As | 0.09As | |
Power | | | | | | |
Infeed power to the backplane bus | | 4.5W | | | | |
Power loss | | | | | | |
Power loss, typ. | 1.8W | 1.9W | 1.9W | 2.4W | 1.7W | 1.5W |
Address area | | | | | | |
Address space per module | | | | | | |
| 32byte; per input / output | 256byte; per input / output | 256byte; per input / output | 288byte; For input and output data respectively | 32byte; For input and output data respectively | 32byte; per input / output |
Address space per station | | | | | | |
| 32byte; per input / output | 512byte; Dependent on configuration | 512byte; Dependent on configuration | 1440byte; Dependent on configuration | 968byte; For input and output data respectively | 244byte; per input / output |
Hardware configuration | | | | | | |
Rack | | | | | | |
| 12 | 32; + 16 ET 200AL modules | 32; + 16 ET 200AL modules | 64; + 16 ET 200AL modules | 30 | 32; + 16 ET 200AL modules |
Submodules | | | | | | |
| | 256 | 256 | 256 | 125 | |
Interfaces | | | | | | |
Number of PROFINET interfaces | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | |
Number of PROFIBUS interfaces | | | | | | 1 |
1. Interface | | | | | | |
Interface types | | | | | | |
| 2 | 2 | 2 | 2 | 2 | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes; 2 integrated RJ45 ports | Yes; Pre-assembled BusAdapter BA 2x RJ45 | | | | |
| | | | | | Yes |
| No | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ (from FS03, V2.2), BA SCRJ / RJ45 (from FS03, V3.1), BA SCRJ / FC (from FS03, V3.1), BA 2x LC (from FS03, V3.3), BA LC / RJ45 (from FS03, V3.3), BA LC / FC (from FS03, V3.3) | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | |
| | | | | | 90mA |
Functionality | | | | | | |
| Yes | Yes | Yes | Yes | Yes | |
| | | | | | Yes |
| Yes | Yes | Yes | Yes | Yes | |
| Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; As MRP or MRPD client; max. 50 or 30 devices in the ring | |
Interface types | | | | | | |
RJ 45 (Ethernet) | | | | | | |
| PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| No | Yes; for Ethernet services | No | No | No | |
| Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
RS 485 | | | | | | |
| | | | | | 12Mbit/s |
PROFINET IO Device | | | | | | |
Services | | | | | | |
| No | No | No | Yes; Bus cycle time: min. 250 s | Yes; Bus cycle time: min. 125 s | |
| Yes | Yes | Yes | Yes | Yes | |
| No | Yes; with send cycles of between 250 s and 4 ms in increments of 125 s | Yes; with send cycles of between 250 s and 4 ms in increments of 125 s | Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 s to 4 ms in 125 s frame | Yes; 125 s, 250 s, 500 s, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 s to 4 ms in 125 s frame | |
| Yes | Yes | Yes | Yes | Yes | |
| No | No | No | No | Yes | |
| No | No | No | Yes; NAP S2 | No | |
| No | Yes | Yes | Yes | Yes | |
| No | Yes | Yes | Yes | Yes | |
| No | Yes | Yes | Yes | Yes | |
| | 2 | 2 | 4 | 4 | |
Open IE communication | | | | | | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
PROFIBUS DP | | | | | | |
Services | | | | | | |
| | | | | | Yes |
| | | | | | Yes |
| | | | | | Yes |
| | | | | | Yes |
Isochronous mode | | | | | | |
Isochronous operation (application synchronized up to terminal) | No | No | No | Yes | Yes | No |
Equidistance | No | | No | Yes | Yes | |
shortest clock pulse | | | | 250s | 125s | |
max. cycle | | | | 4ms | 4ms | |
Bus cycle time (TDP), min. | | | | 250s | 125s | |
Jitter, max. | | | | 1s | 0.25s | |
Interrupts/diagnostics/status information | | | | | | |
Status indicator | Yes | Yes | Yes | Yes | Yes | Yes |
Alarms | Yes | Yes | Yes | Yes | Yes | Yes |
Diagnostic functions | Yes | Yes | Yes | Yes | Yes | Yes |
Diagnostics indication LED | | | | | | |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED |
| Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED |
| Yes; yellow LED | Yes; yellow LED | Yes; yellow LED | Yes; yellow LED | Yes; yellow LED | Yes; yellow LED |
| Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED |
| Yes; 2x green LED | | Yes; 2x green link LEDs on BusAdapter | | | |
| | | | | | Yes; Green DP LED |
| | Yes; 2x green link LEDs on BusAdapter | | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | |
Potential separation | | | | | | |
between backplane bus and electronics | No | No | No | No | No | No |
between PROFIBUS DP and all other circuit components | | | | | | Yes |
between PROFINET and all other circuits | Yes | Yes; 1500 V AC | Yes | Yes | Yes | |
between supply and all other circuits | No | No | Yes | Yes | No | Yes |
Permissible potential difference | | | | | | |
between different circuits | | Safety extra low voltage SELV | | | | 75 V DC/60 V AC (base isolation) |
Isolation | | | | | | |
Isolation tested with | | 707 V DC (type test) | 707 V DC between supply voltage and electronics; 1 500 V AC between Ethernet and electronics | 707 V DC between supply voltage and electronics (type test); 1 500 V AC between Ethernet and electronics (type test) | 707 V DC between supply voltage and electronics (type test); 1 500 V AC between Ethernet and electronics (type test) | 707 V DC (type test) |
Standards, approvals, certificates | | | | | | |
Network loading class | 2 | 2 | 2 | 3 | 3 | |
Security level | | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | |
Ambient conditions | | | | | | |
Ambient temperature during operation | | | | | | |
| 0C | 0C | 0C | 0C | 0C | 0C |
| 60C | 60C | 60C | 60C | 60C | 60C |
| 0C | 0C | 0C | 0C | 0C | 0C |
| 50C | 50C | 50C | 50C | 50C | 50C |
Connection method | | | | | | |
ET-Connection | | | | | | |
| No | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | No | Yes; + 16 ET 200AL modules |
Dimensions | | | | | | |
Width | 35mm | 50mm | 50mm | 50mm | 50mm | 50mm |
Height | 117mm | 117mm | 117mm | 117mm | 117mm | 117mm |
Depth | 74mm | 74mm | 74mm | 74mm | 74mm | 74mm |
Weights | | | | | | |
Weight, approx. | 125g | 190g; IM 155-6 PN BA with 2x RJ45 ports and server module | 147g; without BusAdapter | 147g; without BusAdapter | 147g; without BusAdapter | 150g |