General information | | | | | | |
Product type designation | IM 155-6 PN BA | IM 155-6 PN ST | IM 155-6 PN ST | IM 155-6 PN HF | IM 155-6 PN HS | IM 155-6 DP HF |
HW functional status | | FS01 | | | | |
Firmware version | V3.2 | V4.1 | V3.3 | V3.3 | V4.0 | V3.1 |
Product function | | | | | | |
| Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M4 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 |
| Yes; Single hot swapping | Yes; Single hot swapping | Yes; Single hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping | Yes; Multi-hot swapping |
Engineering with | | | | | | |
| V13 SP1 | V14 | V13 SP1 | V13 SP1 Update 6 | STEP 7 V14 or higher | V13 SP1 |
| V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher | V5.5 SP4 and higher |
| | | | | | One GSD file each, Revision 3 and 5 and higher |
| V2.3 / - | V2.3 / - | V2.3 / - | - / V2.3 | - / V2.3 | |
Configuration control | | | | | | |
via dataset | Yes | Yes | Yes | Yes | Yes | Yes |
Supply voltage | | | | | | |
Type of supply voltage | | | | | | DC |
Rated value (DC) | 24 V | 24 V | 24 V | 24 V | 24 V | 24 V |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V | 19.2 V | 19.2 V | 19.2 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
Reverse polarity protection | Yes | Yes | Yes | Yes | Yes | Yes |
Short-circuit protection | | Yes | | | | |
Mains buffering | | | | | | |
| 5 ms | 10 ms | 5 ms | 5 ms | 5 ms | 5 ms |
Input current | | | | | | |
Current consumption (rated value) | | 450 mA | | | | |
Current consumption, max. | 300 mA | 550 mA | 450 mA | 700 mA | 500 mA | 250 mA |
Inrush current, max. | | 3.7 A | 3.7 A | 4.5 A | 4.5 A | 4.5 A |
IІt | 0.09 AІ·s | 0.09 AІ·s | 0.09 AІ·s | 0.09 AІ·s | 0.09 AІ·s | |
Power | | | | | | |
Infeed power to the backplane bus | | 4.5 W | | | | |
Power loss | | | | | | |
Power loss, typ. | 1.8 W | 1.9 W | 1.9 W | 2.4 W | 1.7 W | 1.5 W |
Address area | | | | | | |
Address space per module | | | | | | |
| 32 byte; per input / output | 256 byte; per input / output | 256 byte; per input / output | 288 byte; For input and output data respectively | 32 byte; For input and output data respectively | 32 byte; per input / output |
Address space per station | | | | | | |
| 32 byte; per input / output | 512 byte; Dependent on configuration | 512 byte; Dependent on configuration | 1 440 byte; Dependent on configuration | 968 byte; For input and output data respectively | 244 byte; per input / output |
Hardware configuration | | | | | | |
Rack | | | | | | |
| 12 | 32; + 16 ET 200AL modules | 32; + 16 ET 200AL modules | 64; + 16 ET 200AL modules | 30 | 32; + 16 ET 200AL modules |
Submodules | | | | | | |
| | 256 | 256 | 256 | 125 | |
Interfaces | | | | | | |
Number of PROFINET interfaces | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | 1; 2 ports (switch) | |
Number of PROFIBUS interfaces | | | | | | 1 |
1. Interface | | | | | | |
Interface types | | | | | | |
| 2 | 2 | 2 | 2 | 2 | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes; 2 integrated RJ45 ports | Yes; Pre-assembled BusAdapter BA 2x RJ45 | | | | |
| | | | | | Yes |
| No | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ (from FS03, V2.2), BA SCRJ / RJ45 (from FS03, V3.1), BA SCRJ / FC (from FS03, V3.1), BA 2x LC (from FS03, V3.3), BA LC / RJ45 (from FS03, V3.3), BA LC / FC (from FS03, V3.3) | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC | |
| | | | | | 90 mA |
Functionality | | | | | | |
| Yes | Yes | Yes | Yes | Yes | |
| | | | | | Yes |
| Yes | Yes | Yes | Yes | Yes | |
| Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; PROFINET MRP | Yes; As MRP or MRPD client; max. 50 or 30 devices in the ring | |
Interface types | | | | | | |
RJ 45 (Ethernet) | | | | | | |
| PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| No | Yes; for Ethernet services | No | No | No | |
| Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
RS 485 | | | | | | |
| | | | | | 12 Mbit/s |
PROFINET IO Device | | | | | | |
Services | | | | | | |
| No | No | No | Yes; Bus cycle time: min. 250 µs | Yes; Bus cycle time: min. 125 µs | |
| Yes | Yes | Yes | Yes | Yes | |
| No | Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs | Yes; with send cycles of between 250 µs and 4 ms in increments of 125 µs | Yes; 250 Ојs, 500 Ојs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | Yes; 125 µs, 250 µs, 500 µs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | |
| Yes | Yes | Yes | Yes | Yes | |
| No | No | No | No | Yes | |
| No | No | No | Yes; NAP S2 | No | |
| No | Yes | Yes | Yes | Yes | |
| No | Yes | Yes | Yes | Yes | |
| No | Yes | Yes | Yes | Yes | |
| | 2 | 2 | 4 | 4 | |
Open IE communication | | | | | | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | Yes | |
PROFIBUS DP | | | | | | |
Services | | | | | | |
| | | | | | Yes |
| | | | | | Yes |
| | | | | | Yes |
| | | | | | Yes |
Isochronous mode | | | | | | |
Isochronous operation (application synchronized up to terminal) | No | No | No | Yes | Yes | No |
Equidistance | No | | No | Yes | Yes | |
shortest clock pulse | | | | 250 µs | 125 µs | |
max. cycle | | | | 4 ms | 4 ms | |
Bus cycle time (TDP), min. | | | | 250 µs | 125 µs | |
Jitter, max. | | | | 1 µs | 0.25 µs | |
Interrupts/diagnostics/status information | | | | | | |
Status indicator | Yes | Yes | Yes | Yes | Yes | Yes |
Alarms | Yes | Yes | Yes | Yes | Yes | Yes |
Diagnostic functions | Yes | Yes | Yes | Yes | Yes | Yes |
Diagnostics indication LED | | | | | | |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED |
| Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED |
| Yes; yellow LED | Yes; yellow LED | Yes; yellow LED | Yes; yellow LED | Yes; yellow LED | Yes; yellow LED |
| Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED | Yes; green PWR LED |
| Yes; 2x green LED | | Yes; 2x green link LEDs on BusAdapter | | | |
| | | | | | Yes; Green DP LED |
| | Yes; 2x green link LEDs on BusAdapter | | Yes; 2x green link LEDs on BusAdapter | Yes; 2x green link LEDs on BusAdapter | |
Potential separation | | | | | | |
between backplane bus and electronics | No | No | No | No | No | No |
between PROFIBUS DP and all other circuit components | | | | | | Yes |
between PROFINET and all other circuits | Yes | Yes; 1500 V AC | Yes | Yes | Yes | |
between supply and all other circuits | No | No | Yes | Yes | No | Yes |
Permissible potential difference | | | | | | |
between different circuits | | Safety extra low voltage SELV | | | | 75 V DC/60 V AC (base isolation) |
Isolation | | | | | | |
Isolation tested with | | 707 V DC (type test) | 707 V DC between supply voltage and electronics; 1 500 V AC between Ethernet and electronics | 707 V DC between supply voltage and electronics (type test); 1 500 V AC between Ethernet and electronics (type test) | 707 V DC between supply voltage and electronics (type test); 1 500 V AC between Ethernet and electronics (type test) | 707 V DC (type test) |
Standards, approvals, certificates | | | | | | |
Network loading class | 2 | 2 | 2 | 3 | 3 | |
Security level | | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | According to Security Level 1 Test Cases V1.1.1 | |
Ambient conditions | | | | | | |
Ambient temperature during operation | | | | | | |
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| 60 °C | 60 °C | 60 °C | 60 °C | 60 °C | 60 °C |
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| 50 °C | 50 °C | 50 °C | 50 °C | 50 °C | 50 °C |
Connection method | | | | | | |
ET-Connection | | | | | | |
| No | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | Yes; + 16 ET 200AL modules | No | Yes; + 16 ET 200AL modules |
Dimensions | | | | | | |
Width | 35 mm | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm |
Height | 117 mm | 117 mm | 117 mm | 117 mm | 117 mm | 117 mm |
Depth | 74 mm | 74 mm | 74 mm | 74 mm | 74 mm | 74 mm |
Weights | | | | | | |
Weight, approx. | 125 g | 190 g; IM 155-6 PN BA with 2x RJ45 ports and server module | 147 g; without BusAdapter | 147 g; without BusAdapter | 147 g; without BusAdapter | 150 g |