Possible applications | |
| | |
| | |
Model | Platform load cell |
Loads | |
Rated load Emax. | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
Minimum initial loading Emin | 0 % Emax |
Maximum working load Lu | 150 % Emax |
Ultimate load Ld | 300 % Emax |
Maximum lateral load Llq | 100 % Emax |
Measurement characteristic values | |
Nominal measurement path snom for | |
| 0.03 mm (0.001 inch) |
| 0.08 mm (0.003 inch) |
| 0.15 mm (0.006 inch) |
| 0.12 mm (0.005 inch) |
| 0.15 mm (0.006 inch) |
| 0.18 mm (0.007 inch) |
| 0.17 mm (0.007 inch) |
| 0.19 mm (0.008 inch) |
Rated characteristic value Cn | 2.0 ± 0.2 mV/V |
Tolerance DO of zero signal | < ± 2.0 % Cn |
Maximum scale interval nlc | |
- emax = 10, 20, 50, 100, 200, 300, 400, 500 kg and accuracy classes C3, C3 MR
| 3 000 |
- emax = 10, 20, 50 kg and accuracy class C4 MR
| 4 000 |
Min. interval Vmin with | |
- emax = 10, 20, 50, 100, 200, 300, 400, 500 kg
(22.05, 44.09, 110.23, 220.46, 440.92, 661.39, 881.85, 1102.31 lb)
| C3: Emax/10 000 C3 MR: Emax/20 000 |
- emax = 10, 20, 50 kg (22.05, 44.09, 110.23 lb)
| C4 MR: Emax/40 000 |
Combined error Fcomb | ≤ ± 0.02 % Cn |
Repeatability Fv | ≤ ± 0.02 % Cn |
Creep error Fcr | |
30 min | ≤ ± 0.025 % Cn |
Temperature coefficient | |
| 0.014 % Cn/10 °C (50 °F) |
| 0.01 % Cn/10 °C (50 °F) |
Electrical characteristic values | |
Recommended reference voltage Uref | 5 … 12 V DC |
Input resistance Re with | |
- 10, 20, 50 kg (22.05, 44.09, 110.23 lb)
| 380 О© ± 15 О© |
- 100, 200, 300, 400, 500 kg (220.46, 440.92, 661.39, 881.85, 1102.31 lb)
| 350 О© ± 3.5 О© |
Output resistance Ra | 350 О© ± 3.5 О© |
Insulation resistance Ris | 5 000 MО© at 50 V DC |
Connection and environmental conditions | |
Material of the load cell (DIN) | Stainless steel |
Maximum tightening torque of the fixing screws with | |
- 10, 20, 50 kg (22.05, 44.09, 110.23 lb)
| 10 Nm |
- 100, 200, 300, 400, 500 kg
(220.46, 440.92, 661.39, 881.85, 1102.31 lb)
| 20 Nm |
Function | Color |
| red |
| black |
- SIG + (measured signal +)
| green |
- SIG – (measured signal -)
| white |
| blue1) |
| yellow1) |
- Shield (not connected to housing)
| transparent |
Rated temperature range Btn | -10 ... +40 °C (14 ... 104 °F) |
Operating temperature range Btu | -35 … +65 °C (-31 ... +149 °F) |
Storage temperature range Bts | -35 … +65 °C (-31 ... +149 °F) |
Degree of protection according to EN 60529; IEC 60529 | IP68, IP69K |
Certificates and approvals | |
Available accuracy classes acc. to OIML R60 | |
- With rated load 10 kg up to 500 kg
| C3, C3 MR |
- With rated load 10 kg, 20 kg, 50 kg
| C4 MR |