Motor protection |
Motor protection with PTC thermistors with 1 (for motors 1LE10 FS 80 and 90) or 3 embedded temperature sensors for tripping | A11 | |
Motor protection with PTC thermistors with 6 embedded temperature sensors for alarm and tripping | A12 | |
Motor temperature detection with embedded temperature sensor KTY 84-130 | A23 | |
Motor temperature detection with embedded temperature sensors 2 x KTY 84‑130 | A25 | |
Temperature detectors for tripping | A31 | |
Installation of 3 PT100 resistance thermometers | A60 | |
Motor connection and connection box |
ECOFAST motor connector Han-Drive 10e for 230 VΔ/400 VY | G55 | |
ECOFAST motor connector EMC Han-Drive 10e for 230 VΔ/400 VY | G56 | |
Connection box on RHS | K09 | |
Connection box on LHS | K10 | |
One metal cable gland | K54 | |
Cable gland, max. configuration | K55 | |
Rotation of the connection box through 90°, entry from DE | K83 | |
Rotation of the connection box through 90°, entry from NDE | K84 | |
Rotation of the connection box through 180° | K85 | |
Next larger connection box | L00 | |
External grounding | L13 | |
3 cables protruding, 0.5 m long | L44 | |
3 cables protruding, 1.5 m long | L45 | |
6 cables protruding, 0.5 m long | L47 | |
6 cables protruding, 1.5 m long | L48 | |
6 cables protruding, 3 m long | L49 | |
Connection box on NDE | M64 | |
Terminal strip for main and auxiliary terminals | M69 | |
Windings and insulation |
Temperature class 155 (F), used acc. to 155 (F), with service factor (SF) | C11 | |
Temperature class 155 (F), used acc. to 155 (F), with increased output | C12 | |
Temperature class 155 (F), used acc. to 155 (F), with increased coolant temperature | C13 | |
Temperature class 180 (H) at rated output and max. CT 60 °C | C18 | |
Increased air humidity/ temperature with 30 to 60 g water per m3 of air | C19 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 45 °C, derating approx. 4 % | C22 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 50 °C, derating approx. 8 % | C23 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 55 °C, derating approx. 13 % | C24 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 60 °C, derating approx.18 % | C25 | |
Increased air humidity/ temperature with 60 to 100 g water per m3 of air | C26 | |
Temperature class 155 (F), used acc. to 130 (B), with higher coolant temperature and/or site altitude | Y50 • and specified output, CT .. °C or SA …. m above sea level | |
Temperature class 155 (F), used acc. to 155 (F), other requirements | Y52 • and specified output, CT .. °C or SA …. m above sea level | |
Colors and paint finish |
Special finish in RAL 7030 stone gray | – | |
Special finish in other standard RAL colors | Y54 • and special finish RAL …. | |
Special finish in special RAL colors | Y51 • and special finish RAL …. | |
Special finish sea air resistant | M94 | |
Unpainted (only cast-iron parts primed) | K23 | |
Unpainted, only primed | K24 | |
Modular technology – Basic versions |
Mounting of separately driven fan | G17 | |
Mounting of brake | G26 | |
Mounting of 1XP8001-1 (HTL) rotary pulse encoder | H57 | |
Mounting of 1XP8001-2 (TTL) rotary pulse encoder | H58 | |
Modular technology – Combinations of basic versions |
Mounting of separately driven fan and 1XP8001-1 rotary pulse encoder | H61 | |
Mounting of brake and 1XP8001-1 rotary pulse encoder | H62 | |
Mounting of brake and separately driven fan | H63 | |
Mounting of brake, separately driven fan and 1XP8001-1 rotary pulse encoder | H64 | |
Mounting of separately driven fan and 1XP8001-2 rotary pulse encoder | H97 | |
Mounting of brake and 1XP8001-2 rotary pulse encoder | H98 | |
Mounting of brake, separately driven fan and 1XP8001-2 rotary pulse Encoder | H99 | |
Modular technology – Additional versions |
Brake supply voltage 24 V DC | C00 | |
Brake supply voltage 400 V AC | C01 | |
Brake supply voltage 180 V DC, for operation on MICROMASTER 411-ECOFAST | C02 | |
Mechanical manual brake release with lever (no locking) | K82 | |
Special technology |
Prepared for mounting of MMI | H15 | |
Mounting of LL 861 900 220 rotary pulse encoder | H70 | |
Mounting of HOG 9 D 024 I rotary pulse encoder | H72 | |
Mounting of HOG 10 D 1024 I rotary pulse encoder | H73 | |
Prepared for mounting of LL 861 900 220 | H78 | |
Prepared for mounting of HOG 9 D 1024 I | H79 | |
Prepared for mounting of HOG 10 D 1024 I | H80 | |
Mechanical design and degrees of protection |
Drive-end seal for flangemounting motors, oil-tight to 0.1 bar | K17 | |
With two additional eyebolts for IM V1/IM V3 | K32 | |
Low-noise version for 2-pole motors with clockwise direction of rotation | K37 | |
Low-noise version for 2-pole motors with counterclockwise direction of rotation | K38 | |
IP65 degree of protection | K50 | |
IP56 degree of protection | K52 | |
Vibration-proof version | L03 | |
Condensation drainage holes | L12 | |
Rust-resistant screws (externally) | M27 | |
Mechanical protection for encoder | M68 | |
Coolant temperature and site altitude |
Coolant temperature –40 to +40 °C | D03 | |
Coolant temperature –30 to +40 °C | D04 | |
Designs in accordance with standards and specifications |
CCC China Compulsory Certification | D01 | |
IE1 motor without CE marking for export outside EEA (see EU Directive 640/2009) | D22 | New! |
Electrical according to NEMA MG1-12 | D30 | |
Design according to UL with "Recognition Mark | D31 | |
Certified for Korea acc. to KS C4202 | D33 | |
China Energy Efficiency Label | D34 | New! |
Canadian regulations (CSA) | D40 | |
NEMA Energy Efficient, North America version according to NEMA MG1, Table 12-11, incl. UL and CSA | D42 | New! |
PSE mark for Japan | D46 | |
VIK version | K30 | |
Ex nA II on VIK rating plate | C27 | |
Bearings and lubrication |
Measuring nipple for SPM shock pulse measurement for bearing inspection | G50 | |
Bearing design for increased cantilever forces | K20 | |
Regreasing device | K40 | |
Located bearing DE | K94 | |
Located bearing NDE | L04 | |
Balance and vibration quantity |
Vibration quantity level A | – | |
Vibration quantity level B | K02 | |
Full-key balancing | L68 | |
Balancing without key | M37 | |
Shaft and rotor |
Concentricity of shaft extension, coaxiality and linear movement in accordance with DIN 42955 Tolerance R for flange-mounting motors | K04 | |
Second standard shaft extension | K16 | |
Shaft extension with standard dimensions, without feather keyway | K42 | |
Concentricity of shaft extension in accordance with DIN 42955 Tolerance R | L39 | |
Standard shaft made of stainless steel | M65 | |
Non-standard cylindrical shaft extension | Y55 • and identification code | |
Heating and ventilation |
Fan cover for textile industry | H17 | |
Metal external fan | K35 | |
Anti-condensation heating for 230 V | K45 | |
Anti-condensation heating for 115 V | K46 | |
Rating plate and extra rating plates |
Second lubrication plate, loose | B06 | |
Extra rating plate for voltage tolerance | B07 | New! |
Second rating plate, loose | K31 | |
Rating plate, stainless steel | M40 | New! |
Extra rating plate or rating plate with deviating rating plate data | Y80 • and identification code | |
Extra rating plate with identification codes | Y82 • and identification code | |
Additional information on rating plate and on package label (max. 20 characters) | Y84 • and identification code | |
Packaging, safety notes, documentation and test certificates |
With one safety and start-up guide per box pallet | B01 | |
Acceptance test certificate 3.1 in acc. with EN 10204 | B02 | |
Printed German/English Operating Instructions (Compact) enclosed | – | |
Printed German/English Operating Instructions enclosed | B23 | |
Type test with heat run for horizontal motors, with acceptance | F83 | |
Wire-lattice pallet | L99 | |
Connected in star for dispatch | M32 | |
Connected in delta for dispatch | M33 | |