Special versions |
Additional identification code -Z with order code and plain text if required |
||
---|---|---|---|
Motor protection |
|||
Motor protection with PTC thermistors with 1 (for motors 1LE10 FS 80 and 90) or 3 embedded temperature sensors for tripping |
A11 |
||
Motor protection with PTC thermistors with 6 embedded temperature sensors for alarm and tripping |
A12 |
||
Motor temperature detection with embedded temperature sensor KTY 84-130 |
A23 |
||
Motor temperature detection with embedded temperature sensors 2 x KTY 84‑130 |
A25 |
||
Temperature detectors for tripping |
A31 |
||
Installation of 3 PT100 resistance thermometers |
A60 |
||
Motor connection and connection box |
|||
ECOFAST motor connector Han-Drive 10e for 230 VΔ/400 VY |
G55 |
||
ECOFAST motor connector EMC Han-Drive 10e for 230 VΔ/400 VY |
G56 |
||
Connection box on RHS |
K09 |
||
Connection box on LHS |
K10 |
||
One metal cable gland |
K54 |
||
Cable gland, max. configuration |
K55 |
||
Rotation of the connection box through 90°, entry from DE |
K83 |
||
Rotation of the connection box through 90°, entry from NDE |
K84 |
||
Rotation of the connection box through 180° |
K85 |
||
Next larger connection box |
L00 |
||
External grounding |
L13 |
||
3 cables protruding, 0.5 m long |
L44 |
||
3 cables protruding, 1.5 m long |
L45 |
||
6 cables protruding, 0.5 m long |
L47 |
||
6 cables protruding, 1.5 m long |
L48 |
||
6 cables protruding, 3 m long |
L49 |
||
Connection box on NDE |
M64 |
||
Terminal strip for main and auxiliary terminals |
M69 |
||
Windings and insulation |
|||
Temperature class 155 (F), used acc. to 155 (F), with service factor (SF) |
C11 |
||
Temperature class 155 (F), used acc. to 155 (F), with increased output |
C12 |
||
Temperature class 155 (F), used acc. to 155 (F), with increased coolant temperature |
C13 |
||
Temperature class 180 (H) at rated output and max. CT 60 °C |
C18 |
||
Increased air humidity/ temperature with 30 to 60 g water per m3 of air |
C19 |
||
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 45 °C, derating approx. 4 % |
C22 |
||
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 50 °C, derating approx. 8 % |
C23 |
||
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 55 °C, derating approx. 13 % |
C24 |
||
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 60 °C, derating approx.18 % |
C25 |
||
Increased air humidity/ temperature with 60 to 100 g water per m3 of air |
C26 |
||
Temperature class 155 (F), used acc. to 130 (B), with higher coolant temperature and/or site altitude |
Y50 • and specified output, CT .. °C or SA …. m above sea level |
||
Temperature class 155 (F), used acc. to 155 (F), other requirements |
Y52 • and specified output, CT .. °C or SA …. m above sea level |
||
Colors and paint finish |
|||
Special finish in RAL 7030 stone gray |
– |
||
Special finish in other standard RAL colors |
Y54 • and special finish RAL …. |
||
Special finish in special RAL colors |
Y51 • and special finish RAL …. |
||
Special finish sea air resistant |
M94 |
||
Unpainted (only cast-iron parts primed) |
K23 |
||
Unpainted, only primed |
K24 |
||
Modular technology – Basic versions |
|||
Mounting of separately driven fan |
G17 |
||
Mounting of brake |
G26 |
||
Mounting of 1XP8001-1 (HTL) rotary pulse encoder |
H57 |
||
Mounting of 1XP8001-2 (TTL) rotary pulse encoder |
H58 |
||
Modular technology – Combinations of basic versions |
|||
Mounting of separately driven fan and 1XP8001-1 rotary pulse encoder |
H61 |
||
Mounting of brake and 1XP8001-1 rotary pulse encoder |
H62 |
||
Mounting of brake and separately driven fan |
H63 |
||
Mounting of brake, separately driven fan and 1XP8001-1 rotary pulse encoder |
H64 |
||
Mounting of separately driven fan and 1XP8001-2 rotary pulse encoder |
H97 |
||
Mounting of brake and 1XP8001-2 rotary pulse encoder |
H98 |
||
Mounting of brake, separately driven fan and 1XP8001-2 rotary pulse Encoder |
H99 |
||
Modular technology – Additional versions |
|||
Brake supply voltage 24 V DC |
C00 |
||
Brake supply voltage 400 V AC |
C01 |
||
Brake supply voltage 180 V DC, for operation on MICROMASTER 411-ECOFAST |
C02 |
||
Mechanical manual brake release with lever (no locking) |
K82 |
||
Special technology |
|||
Prepared for mounting of MMI |
H15 |
||
Mounting of LL 861 900 220 rotary pulse encoder |
H70 |
||
Mounting of HOG 9 D 024 I rotary pulse encoder |
H72 |
||
Mounting of HOG 10 D 1024 I rotary pulse encoder |
H73 |
||
Prepared for mounting of LL 861 900 220 |
H78 |
||
Prepared for mounting of HOG 9 D 1024 I |
H79 |
||
Prepared for mounting of HOG 10 D 1024 I |
H80 |
||
Mechanical design and degrees of protection |
|||
Drive-end seal for flangemounting motors, oil-tight to 0.1 bar |
K17 |
||
With two additional eyebolts for IM V1/IM V3 |
K32 |
||
Low-noise version for 2-pole motors with clockwise direction of rotation |
K37 |
||
Low-noise version for 2-pole motors with counterclockwise direction of rotation |
K38 |
||
IP65 degree of protection |
K50 |
||
IP56 degree of protection |
K52 |
||
Vibration-proof version |
L03 |
||
Condensation drainage holes |
L12 |
||
Rust-resistant screws (externally) |
M27 |
||
Mechanical protection for encoder |
M68 |
||
Coolant temperature and site altitude |
|||
Coolant temperature –40 to +40 °C |
D03 |
||
Coolant temperature –30 to +40 °C |
D04 |
||
Designs in accordance with standards and specifications |
|||
CCC China Compulsory Certification |
D01 |
||
IE1 motor without CE marking for export outside EEA (see EU Directive 640/2009) |
D22 |
New! |
|
Electrical according to NEMA MG1-12 |
D30 |
||
Design according to UL with "Recognition Mark |
D31 |
||
Certified for Korea acc. to KS C4202 |
D33 |
||
China Energy Efficiency Label |
D34 |
New! |
|
Canadian regulations (CSA) |
D40 |
||
NEMA Energy Efficient, North America version according to NEMA MG1, Table 12-11, incl. UL and CSA |
D42 |
New! |
|
PSE mark for Japan |
D46 |
||
VIK version |
K30 |
||
Ex nA II on VIK rating plate |
C27 |
||
Bearings and lubrication |
|||
Measuring nipple for SPM shock pulse measurement for bearing inspection |
G50 |
||
Bearing design for increased cantilever forces |
K20 |
||
Regreasing device |
K40 |
||
Located bearing DE |
K94 |
||
Located bearing NDE |
L04 |
||
Balance and vibration quantity |
|||
Vibration quantity level A |
– |
||
Vibration quantity level B |
K02 |
||
Full-key balancing |
L68 |
||
Balancing without key |
M37 |
||
Shaft and rotor |
|||
Concentricity of shaft extension, coaxiality and linear movement in accordance with DIN 42955 Tolerance R for flange-mounting motors |
K04 |
||
Second standard shaft extension |
K16 |
||
Shaft extension with standard dimensions, without feather keyway |
K42 |
||
Concentricity of shaft extension in accordance with DIN 42955 Tolerance R |
L39 |
||
Standard shaft made of stainless steel |
M65 |
||
Non-standard cylindrical shaft extension |
Y55 • and identification code |
||
Heating and ventilation |
|||
Fan cover for textile industry |
H17 |
||
Metal external fan |
K35 |
||
Anti-condensation heating for 230 V |
K45 |
||
Anti-condensation heating for 115 V |
K46 |
||
Rating plate and extra rating plates |
|||
Second lubrication plate, loose |
B06 |
||
Extra rating plate for voltage tolerance |
B07 |
New! |
|
Second rating plate, loose |
K31 |
||
Rating plate, stainless steel |
M40 |
New! |
|
Extra rating plate or rating plate with deviating rating plate data |
Y80 • and identification code |
||
Extra rating plate with identification codes |
Y82 • and identification code |
||
Additional information on rating plate and on package label (max. 20 characters) |
Y84 • and identification code |
||
Packaging, safety notes, documentation and test certificates |
|||
With one safety and start-up guide per box pallet |
B01 |
||
Acceptance test certificate 3.1 in acc. with EN 10204 |
B02 |
||
Printed German/English Operating Instructions (Compact) enclosed |
– |
||
Printed German/English Operating Instructions enclosed |
B23 |
||
Type test with heat run for horizontal motors, with acceptance |
F83 |
||
Wire-lattice pallet |
L99 |
||
Connected in star for dispatch |
M32 |
||
Connected in delta for dispatch |
M33 |