Standards | | IEC/EN 60947-5-1, EN ISO 14119 |
Data according to AS-Interface specification | | |
- I/O configuration / ID configuration
| | 0 / B |
- ID1 code / ID2 code (Hex)
| | F / F |
- Power consumption, overall
| mA | ≤ 60 |
Inputs | | |
| | Contact open |
| | Contact closed, Iin dynamic (Ipeak ≥ 5 mA |
Status display | | Green/red dual LED |
Rated impulse withstand voltage Uimp | kV | 0.6 |
EMC strength | | |
| kV | 4 |
| V/m | 10 |
| kV | 1 / 2 |
Mechanical endurance | | |
| | 15 Г— 106 operating cycles |
- With separate actuator, 3SF1...-..V..
| | 1 Г— 106 operating cycles |
PFH value Probability of failure upon request of the safety function, with 1 actuation per hour and B10 = 5 Г— 106 | | |
| | 4 x 10-9 1/h |
- With separate actuator, 3SF1...-..V..
| | 2 x 10-9 1/h |
- Hinge switches, 3SF1...-..U..
| | 2 x 10-9 1/h |
Shock resistance acc. to IEC 60068-2-27 | | 30 g / 11 ms |