 - Connection of SIMATIC S7-400 to Industrial Ethernet
- Multi-protocol operation for ISO, TCP/IP, UDP and PROFINET IO protocols
- Adjustable keep-alive function
- Two separate interfaces (integrated network separation):
- Gigabit interface with one RJ45 port with 10/100/1 000 Mbit/s, full/half-duplex with auto-sensing capability
- PROFINET interface with four RJ45 ports with 10/100 Mbit/s, full/half duplex with autosensing and autocrossover functionality via integrated 4-port switch
- Communications services via both interfaces
- Open communication (ISO, TCP/IP and UDP), multicast with UDP, including routing between both interfaces
- PG/OP communication:
Cross-network by means of S7 routing - S7 communication (client, server, multiplexing) including routing between both interfaces
- IT communication:
HTTP communication supports access to process data via own Web pages; e-mail client function, sending of e-mails with authentication directly from user program; FTP communication supports program-controlled FTP client communication; access to data blocks through FTP server
- Communications services via PROFINET interface
- PROFINET IO controller with real-time properties (RT and IRT)
- PROFINET CBA
- IP address assignment via DHCP, simple PC tool or via the user program (e.g. HMI)
- Support of the prioritized startup of PROFINET IO devices
- Configuration with STEP 7
- Media redundancy (MRP);
the CP supports the media redundancy procedure MRP within an Ethernet network with ring topology. - Access protection by means of configurable IP access list
- Module replacement without programming device;
all information is stored on the C-PLUG (also file system for IT functions) - Extensive diagnostic functions for all modules in the rack
- Integration into network management systems through the support of SNMP V1 MIB-II
- Operation in the SIMATIC H system for redundant S7-communication
- Operation in fail-safe applications (PROFIsafe) in combination with SIMATIC S7-400 CPU 416F
Note:SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added. SIPLUS CP 443-1 Advanced | | Article No. | 6AG1443-1GX30-4XE0 | Order number based on | 6GK7443-1GX30-0XE0 | Ambient temperature range | 0 ... +60 °C | Conformal coating | Coating of the printed circuit boards and the electronic components | Technical data | The technical data of the standard product applies, except for the ambient conditions | Ambient conditions | Relative humidity | 100%, condensation/frost permitted. No commissioning in bedewed state. | Biologically active substances, compliance with EN 60721-3-3 | Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation! | Chemically active substances, compliance with EN 60721-3-3 | Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation! | Mechanically active substances, compliance with EN 60721-3-3 | Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation! | Air pressure (depending on the highest positive temperature range specified) | 1 080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range 795 ... 658 hPa (+2 000 ... +3 500 m) derating 10 K 658 ... 540 hPa (+3 500 ... +5 000 m) derating 20 K |
Technical documentation on SIPLUS can be found here: http://www.siemens.de/siplus-extreme
|
|