Article number | 6AG1223-1BH32-2XB0 | 6AG1223-1BH32-4XB0 | 6AG1223-1PH32-2XB0 | 6AG1223-1PH32-4XB0 |
|---|
| SIPLUS S7-1200 SM 1223 8DI/8DQ | SIPLUS S7-1200 SM 1223 8DI/8DQ | SIPLUS S7-1200 SM 1223 8DI/8DQ RLY | SIPLUS S7-1200 SM 1223 8DI/8DQ RLY |
|---|
Supply voltage | | | | | Rated value (DC) | | | | | | Yes | Yes | Yes | Yes | permissible range, lower limit (DC) | 20.4V | 20.4V | 20.4V | 20.4V | permissible range, upper limit (DC) | 28.8V | 28.8V | 28.8V | 28.8V | Input current | | | | | from backplane bus 5 V DC, max. | 145mA | 145mA | 145mA | 145mA | Digital inputs | | | | | | 4mA; per channel | 4mA; per channel | 4 mA/input 11 mA/relay | 4 mA/input 11 mA/relay | Output voltage | | | | | Power supply to the transmitters | | | | | | Yes | Yes | Yes | Yes | Power loss | | | | | Power loss, typ. | 2.5W | 2.5W | 5.5W | 5.5W | Digital inputs | | | | | Number of digital inputs | 8 | 8 | 8 | 8 | | 2 | 2 | 2 | 2 | Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes | Yes | Yes | Number of simultaneously controllable inputs | | | | | all mounting positions | | | | | | 8 | 8 | 8 | 8 | horizontal installation | | | | | | 8 | 8 | 8 | 8 | | 8 | 8 | 8 | 8 | vertical installation | | | | | | 8 | 8 | 8 | 8 | Input voltage | | | | | | DC | DC | DC | DC | | 24V | 24V | 24V | 24V | | 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | Input current | | | | | | 1mA | 1mA | 1mA | 1mA | | 2.5mA | 2.5mA | 2.5mA | 2.5mA | | 4mA | 4mA | 4mA | 4mA | Input delay (for rated value of input voltage) | | | | | for standard inputs | | | | | | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | for interrupt inputs | | | | | | Yes | Yes | Yes | Yes | Cable length | | | | | | 500m | 500m | 500m | 500m | | 300m | 300m | 300m | 300m | Digital outputs | | | | | Number of digital outputs | 8 | 8 | 8 | 8 | | 1 | 1 | 2 | 2 | Short-circuit protection | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally | Limitation of inductive shutdown voltage to | L+ (-48 V) | L+ (-48 V) | | | Switching capacity of the outputs | | | | | | 0.5A | 0.5A | 2A | 2A | | 5W | 5W | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | Output voltage | | | | | | 24V | 24V | 5 V DC to 30 V DC | 5 V DC to 30 V DC | | | | 5 V AC to 250 V AC | 5 V AC to 250 V AC | | 0.1V; with 10 kOhm load | 0.1V; with 10 kOhm load | | | | 20 V DC | 20 V DC | | | Output current | | | | | | 0.5A | 0.5A | 2A | 2A | | 10A | 10A | | | Output delay with resistive load | | | | | | 50s | 50s | 10ms | 10ms | | 200s | 200s | 10ms | 10ms | Total current of the outputs (per group) | | | | | horizontal installation | | | | | | 4A; Current per mass | 4A; Current per mass | 10A; Current per mass | 10A; Current per mass | Relay outputs | | | | | | | | 8 | 8 | | | | 24V | 24V | | | | mechanically 10 million, at rated load voltage 100 000 | mechanically 10 million, at rated load voltage 100 000 | Switching capacity of contacts | | | | | | 0.5A | 0.5A | 2A | 2A | | 5W | 5W | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | | 0.5A | 0.5A | 2A | 2A | Cable length | | | | | | 500m | 500m | 500m | 500m | | 150m | 150m | 150m | 150m | Interrupts/diagnostics/status information | | | | | Alarms | Yes | Yes | Yes | Yes | Diagnostic functions | Yes | Yes | Yes | Yes | Alarms | | | | | | Yes | Yes | Yes | Yes | Diagnostic messages | | | | | | Yes | Yes | Yes | Yes | Diagnostics indication LED | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Potential separation | | | | | Potential separation digital inputs | | | | | | 2 | 2 | 2 | 2 | Potential separation digital outputs | | | | | | | | Relays | Relays | | 1 | 1 | 2 | 2 | | 500 V AC | 500 V AC | 1500 V AC for 1 minute | 1500 V AC for 1 minute | Permissible potential difference | | | | | between different circuits | | | 750 V AC for 1 minute | 750 V AC for 1 minute | Degree and class of protection | | | | | Degree of protection acc. to EN 60529 | | | | | | Yes | Yes | Yes | Yes | Standards, approvals, certificates | | | | | CE mark | Yes | Yes | Yes | Yes | Ambient conditions | | | | | Free fall | | | | | | 0.3m; five times, in product package | 0.3m; five times, in product package | 0.3m; five times, in product package | 0.3m; five times, in product package | Ambient temperature during operation | | | | | | -40C; = Tmin; Startup @ -25 C | -20C; = Tmin; Startup @ 0 C | -40C; = Tmin; Startup @ -25 C | -20C; = Tmin; Startup @ 0 C | | 70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 4, inputs 4 (no adjacent points) for horizontal mounting position | 60C; = Tmax | 70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 4, inputs 4 (no adjacent points) for horizontal mounting position | 60C; = Tmax | | 5C to 55C, 3C / minute | | | | | -25C | | | | Ambient temperature during storage/transportation | | | | | | -40C | -40C | -40C | -40C | | 70C | 70C | 70C | 70C | Altitude during operation relating to sea level | | | | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | | | | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | Use in stationary industrial systems | | | | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Connection method | | | | | required front connector | Yes | Yes | Yes | Yes | Mechanics/material | | | | | Enclosure material (front) | | | | | | Yes | Yes | Yes | Yes | Dimensions | | | | | Width | 45mm | 45mm | 45mm | 45mm | Height | 100mm | 100mm | 100mm | 100mm | Depth | 75mm | 75mm | 75mm | 75mm | Weights | | | | | Weight, approx. | 210g | 210g | 230g | 230g |
Article number | 6AG1223-1PL32-2XB0 | 6AG1223-1PL32-4XB0 | 6AG1223-1BL32-2XB0 | 6AG1223-1BL32-4XB0 |
|---|
| SIPLUS S7-1200 SM 1223 16DI/16DQ RLY | SIPLUS S7-1200 SM 1223 16DI/16DQ RLY | SIPLUS S7-1200 SM 1223 16DI/16DQ | SIPLUS S7-1200 SM 1223 16DI/16DQ |
|---|
Supply voltage | | | | | Rated value (DC) | | | | | | Yes | Yes | Yes | Yes | permissible range, lower limit (DC) | 20.4V | 20.4V | 20.4V | 20.4V | permissible range, upper limit (DC) | 28.8V | 28.8V | 28.8V | 28.8V | Input current | | | | | from backplane bus 5 V DC, max. | 180mA | 180mA | 185mA | 185mA | Digital inputs | | | | | | 4 mA/input 11 mA/relay | 4 mA/input 11 mA/relay | 4mA; per channel | 4mA; per channel | Output voltage | | | | | Power supply to the transmitters | | | | | | Yes | Yes | Yes | Yes | Power loss | | | | | Power loss, typ. | 10W | 10W | 4.5W | 4.5W | Digital inputs | | | | | Number of digital inputs | 16 | 16 | 16 | 16 | | 2 | 2 | 2 | 2 | Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes | Yes | Yes | Number of simultaneously controllable inputs | | | | | all mounting positions | | | | | | 16 | 16 | 16 | 16 | horizontal installation | | | | | | 16 | 16 | 16 | 16 | | 16 | 16 | 16 | 16 | vertical installation | | | | | | 16 | 16 | 16 | 16 | Input voltage | | | | | | DC | DC | DC | DC | | 24V | 24V | 24V | 24V | | 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA | | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | Input current | | | | | | 1mA | 1mA | 1mA | 1mA | | 2.5mA | 2.5mA | 2.5mA | 2.5mA | | 4mA | 4mA | 4mA | 4mA | Input delay (for rated value of input voltage) | | | | | for standard inputs | | | | | | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | for interrupt inputs | | | | | | Yes | Yes | Yes | Yes | Cable length | | | | | | 500m | 500m | 500m | 500m | | 300m | 300m | 300m | 300m | Digital outputs | | | | | Number of digital outputs | 16 | 16 | 16 | 16 | | 4 | 4 | 1 | 1 | Short-circuit protection | No; to be provided externally | No; to be provided externally | No; to be provided externally | No; to be provided externally | Limitation of inductive shutdown voltage to | | | L+ (-48 V) | L+ (-48 V) | Switching capacity of the outputs | | | | | | 2A | 2A | 0.5A | 0.5A | | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | 5W | 5W | Output voltage | | | | | | 5 V DC to 30 V DC | 5 V DC to 30 V DC | 24V | 24V | | 5 V AC to 250 V AC | 5 V AC to 250 V AC | | | | | | 0.1V; with 10 kOhm load | 0.1V; with 10 kOhm load | | | | 20 V DC | 20 V DC | Output current | | | | | | 2A | 2A | 0.5A | 0.5A | | | | 10A | 10A | Output delay with resistive load | | | | | | 10ms | 10ms | 50s | 50s | | 10ms | 10ms | 200s | 200s | Total current of the outputs (per group) | | | | | horizontal installation | | | | | | 8A; Current per mass | 8A; Current per mass | 8A; Current per mass | 8A; Current per mass | Relay outputs | | | | | | 16 | 16 | | | | 24V | 24V | | | | mechanically 10 million, at rated load voltage 100 000 | mechanically 10 million, at rated load voltage 100 000 | | | Switching capacity of contacts | | | | | | 2A | 2A | 0.5A | 0.5A | | 30 W with DC, 200 W with AC | 30 W with DC, 200 W with AC | 5W | 5W | | 2A | 2A | 0.5A | 0.5A | Cable length | | | | | | 500m | 500m | 500m | 500m | | 150m | 150m | 150m | 150m | Interrupts/diagnostics/status information | | | | | Alarms | Yes | Yes | Yes | Yes | Diagnostic functions | Yes | Yes | Yes | Yes | Alarms | | | | | | Yes | Yes | Yes | Yes | Diagnostic messages | | | | | | Yes | Yes | | | Diagnostics indication LED | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Potential separation | | | | | Potential separation digital inputs | | | | | | 2 | 2 | 2 | 2 | Potential separation digital outputs | | | | | | Relays | Relays | | | | 4 | 4 | 1 | 1 | | 1500 V AC for 1 minute | 1500 V AC for 1 minute | 500 V AC | 500 V AC | Permissible potential difference | | | | | between different circuits | 750 V AC for 1 minute | 750 V AC for 1 minute | | | Degree and class of protection | | | | | Degree of protection acc. to EN 60529 | | | | | | Yes | Yes | Yes | Yes | Standards, approvals, certificates | | | | | CE mark | Yes | Yes | Yes | Yes | Ambient conditions | | | | | Free fall | | | | | | 0.3m; five times, in product package | 0.3m; five times, in product package | 0.3m; five times, in product package | 0.3m; five times, in product package | Ambient temperature during operation | | | | | | -40C; = Tmin; Startup @ -25 C | -20C; = Tmin; Startup @ 0 C | -40C; = Tmin; Startup @ -25 C | -20C; = Tmin; Startup @ 0 C | | 70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 8, inputs 8 (no adjacent points) for horizontal mounting position | 60C; = Tmax | 70C; = Tmax; Tmax > +60 C number of simultaneously activated outputs 8, inputs 8 (no adjacent points) for horizontal mounting position | 60C; = Tmax | Ambient temperature during storage/transportation | | | | | | -40C | -40C | -40C | -40C | | 70C | 70C | 70C | 70C | Altitude during operation relating to sea level | | | | | | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Relative humidity | | | | | | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) | Use in stationary industrial systems | | | | | | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Connection method | | | | | required front connector | Yes | Yes | Yes | Yes | Mechanics/material | | | | | Enclosure material (front) | | | | | | Yes | Yes | Yes | Yes | Dimensions | | | | | Width | 70mm | 70mm | 70mm | 70mm | Height | 100mm | 100mm | 100mm | 100mm | Depth | 75mm | 75mm | 75mm | 75mm | Weights | | | | | Weight, approx. | 350g | 350g | 310g | 310g |
|
|