Design and equipment features | | | |
Design | | | |
19" rack | 4 U | 2 U | 4 U |
Ready for telescopic rails​ | Yes | Yes | Yes |
Horizontal/vertical installation | Yes/Yes | Yes/No | Yes/Yes |
19" fixing bracket with handle; dismountable from outside | Yes | Yes | Yes |
Tower kit (accessory) | Yes | No | Yes |
Degree of protection | IP30 at front (front door closed); IP20 at the rear according to EN 60529 | IP41 at front (front door closed); IP20 at the rear according to EN 60529 | IP41 at front (front door closed); IP20 at the rear according to EN 60529 |
Dust protection | With closed front door in conformity with IEC 60529 Filter class G2 EN 779, particles > 0.5 mm are blocked by 99% | With closed front door in conformity with IEC 60529 Filter class G2 EN 779, particles > 0.5 mm are blocked by 99% | With closed front door in conformity with IEC 60529 Filter class G2 EN 779, particles > 0.5 mm are blocked by 99% |
Chipset | Intel C236 (GL82C236 PCH) | Intel C226 (DH82C226 PCH) | Intel C226 (DH82C226 PCH) |
CPU | | | |
Processor, clock | - Intel Xeon Processor E3‑1275 v5 4C/8T, 3.6 (4.0) GHz, 8 MB cache, iAMT
- Intel Core i7-6700 4C/8T, 3.4 (4.0) GHz, 8 MB cache, iAMT
- Intel Core i5-6500 4C/4T, 3.2 (3.6) GHz, 6 MB cache, iAMT
| - Intel Xeon E3‑1268L v3, 4 cores, 8 threads, 2.3 (3.3) GHz, GT2, 8 MB cache, Turbo Boost, VT‑d, iAMT
- Intel Core i5‑4570TE, 2 cores, 4 threads, 2.7 (3.3) GHz, GT2, 4 MB cache, Turbo Boost, VT‑d, iAMT
- Intel Core i3‑4330TE, 2 cores, 4 threads, 2.4 GHz, GT2, 4 MB cache
| - Intel Xeon E3‑1268L v3, 4 cores, 8 threads, 2.3 (3.3) GHz, GT2, 8 MB cache, Turbo Boost, VT‑d, iAMT
- Intel Core i5‑4570TE, 2 cores, 4 threads, 2.7 (3.3) GHz, GT2, 4 MB cache, Turbo Boost, VT‑d, iAMT
- Intel Core i3‑4330TE, 2 cores, 4 threads, 2.4 GHz, GT2, 4 MB cache
|
Main memory (SDRAM) | | | |
Type | DDR4-2133 SDRAM (PC4‑2400T) | DDR3-1600 SDRAM (PC3‑12800), with or without ECC | DDR3-1600 SDRAM (PC3‑12800), with or without ECC |
Maximum configuration | 4 DIMM memory sockets in total; together up to 64 GB | 4 DIMM memory sockets in total; together up to 32 GB | 4 DIMM memory sockets in total; together up to 32 GB |
Standard configuration | 4 GB DDR4-2133 SDRAM (1 × 4 GB); single channel 8 GB DDR4-2133 SDRAM (2 × 4 GB); dual channel 16 GB DDR4-2133 SDRAM (2 × 8 GB); dual channel 32 GB DDR4-2133 SDRAM (2 × 16 GB); dual channel 64 GB DDR4-2133 SDRAM (4 × 16 GB); dual channel 8 GB or more can be selected for OS server or ES/OS single station 4 GB or more can be selected for OS client | 4 GB DDR3 SDRAM (2 × 2 GB); dual channel 4 GB DDR3 SDRAM (1 × 4 GB); single channel, ECC 8 GB DDR3 SDRAM (2 × 4 GB); dual channel (without/with ECC) 16 GB DDR3 SDRAM (2 × 8 GB); dual channel (without/with ECC) 32 GB DDR3 SDRAM (4 × 8 GB); dual channel (without/with ECC) 8 GB or more can be selected for OS server or ES/OS single station 4 GB and more can be selected for OS client | 8 GB DDR3 SDRAM (2 × 4 GB); dual channel (without/with ECC) 16 GB DDR3 SDRAM (2 × 8 GB); dual channel (without/with ECC) 32 GB DDR3 SDRAM (4 × 8 GB); dual channel (without/with ECC) 8 GB or more can be selected for OS server or ES/OS single station |
Motherboard slots | Total of 7 slots: - 2 × PCI
1 × PCIe x4 (1 lane, Gen 3.0) 1 × PCIe x4 (4 lanes, Gen 3.0) 1 × PCIe x8 (1 lane, Gen 3.0) 1 × PCIe x16 (4 lanes, Gen 3.0) 1 × PCIe x16; Gen 3.0
Modules up to 312 mm in length can be used | Selectable bus modules with total of 4 slots: - 2 × PCIe x16 (8 lanes, Gen 3.0) and 2 × PCI
- 1 × PCIe x16 (8 lanes, Gen 3.0), 1 × PCIe x16 (4 lanes, Gen 2.0); 2 × PCIe x16 (4 lanes, Gen 3.0)
Modules up to 312 mm in length can be used | Bus module with total of 11 slots: 1 × PCIe x16 (8 lanes, Gen 3.0) 2 × PCIe x16 (4 lanes, Gen 3.0) 2 × PCIe x16 (4 lanes, Gen 2.0) 3 × PCIe x4 (4 lanes, Gen 2.0) 3 × PCI Modules up to 312 mm in length can be used |
Possible slots for SATA drives | | | |
On the front | Alternative for HDD/SSD: 1 × 5.25" + 3 × slimline removable trays 3.5" or 4 × slimline removable trays 3.5" 1 × 3.5" (slimline) for DVD burner | 2 × slimline removable drive bay 3.5" for HDD/SSD 1 × 3.5" (slimline) for DVD burner | 4 × slimline removable drive bay 3.5" for HDD/SSD 1 × 3.5" (slimline) for DVD burner |
Indoors | 2 × 3.5" for HDD/SSD | 2 × 3.5" for HDD (in shock and vibration-damped drive cage; alternative to removable drive bay) | 2 × 3.5" for HDD in shock and vibration-damped drive cage 2 × 3.5" for HDD/SSD, integral |
RAID controller | | | |
Onboard RAID controller | Intel PCH with Intel Rapid Storage Technology | Intel 8 series SATA RAID controller | Intel 8 series SATA RAID controller |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Hardware RAID controller (PCI x8; 2 slots occupied) | | | |
| No | Yes | Yes |
| No | No | Yes |
Drives | | | |
Hard disk drive (HDD) 3.5", 6 Gbps, NCQ technology | | | |
- ES/OS Single station or OS Server
| 1 TB; Enterprise type: 1 TB or 2 TB | 500 GB SATA, 1 TB SATA or 1 TB SAS | 500 GB SATA, 1 TB SATA or 1 TB SAS |
| 1 TB; Enterprise type: 1 TB or 2 TB | 500 GB or 1 TB SATA | 500 GB or 1 TB SATA |
Solid State Drive (SSD) 2.5" | | | |
- ES/OS Single station or OS Server
| 240 GB or 480 GB SATA (eMLC) | 240 GB or 480 GB SATA (eMLC) | 240 GB or 480 GB SATA (eMLC) |
| 240 GB or 480 GB SATA (eMLC) | 240 GB or 480 GB SATA (eMLC) | – |
DVD burner | DVD±R/RW 5.25" SATA Slimline Read: - DVD‑ROM: single layer and dual layer 8x
- DVD‑R/+R 8x
- DVD‑RW/+RW 8x
- DVD‑RAM 8x
- CD-ROM, CD‑R 24x, CD‑RW 24x
Write: - DVD+R 8x,
DVD+R DL 6x DVD+RW 8x, DVD‑R 8x, DVD‑R DL 6x DVD‑RW 6x - DVD-RAM 5x
- CD‑R 10x, CD‑RW 16x
| DVD±R/RW 5.25" SATA Slimline Read: - DVD‑ROM: single layer 8x, dual layer 6x
- DVD-R/+R: single layer 8x, dual layer 6x
- DVD‑RW/+RW 8x
- DVD‑RAM 5x
- CD‑R 24x, CD‑RW 24x
Write: - DVD+R 8x, DVD+RW 8x, DVD‑R 8x, DVD‑RW 6x
- DVD+R9 (DL) 6x, DVD‑R DL 2x
- CD‑R 24x, CD‑RW 24x
| DVD±R/RW 5.25" SATA Slimline Read: - DVD‑ROM: single layer 8x, dual layer 6x
- DVD-R/+R: single layer 8x, dual layer 6x
- DVD‑RW/+RW 8x
- DVD‑RAM 5x
- CD‑ROM, CD‑R 24x, CD‑RW 24x
Write: - DVD+R 8x, DVD+RW 8x, DVD‑R 8x, DVD‑RW 6x
- DVD+R (DL) 6x, DVD‑R DL 2x
- CD‑R 24x, CD‑RW 24x
|
HDD/SSD configuration | HDD (single station, server or client) - 1 TB HDD SATA internal (optionally Enterprise type) 0.2 g vibration, 1 g shock
- 1 TB HDD SATA in removable tray, at the front (optionally Enterprise type)
- 1 TB RAID 1 internal; 0.2 g vibration, 1 g shock (2 × 1 TB HDD SATA, optionally Enterprise type, data mirroring)
- 1 TB RAID 1 in removable trays; hot-swap; at the front (2 × 1 TB HDD SATA, optionally Enterprise type, data mirroring)
- 2 TB RAID 1 in removable trays; hot-swap; at the front (2 × 2 TB HDD SATA, Enterprise type, data mirroring)
- 2 TB RAID 1 (2 × 2 TB HDD SATA, data mirroring) plus 2 TB hot-spare HDD SATA; each Enterprise type; in removable trays; hot-swap; at the front
SSD (single station, server or client) - 240 GB or 480 GB SSD SATA internal
- 240 GB or 480 GB SSD SATA in removable tray; at the front
- 240 or 480 GB RAID 1 (2 × 240/480 GB SSD SATA) in removable trays, hot-swap, at the front
HDD+SSD (single station or server) - 2 TB RAID 1 (2 × 2 TB HDD SATA, Enterprise type, data mirroring), hot-swap, plus 480 GB SSD SATA; each in removable trays; at the front
| HDD (single station, server or client) - 500 GB or 1 TB HDD SATA, internal; 0.5 g vibration, 5 g shock
- 500 GB or 1 TB HDD SATA in removable drive bay; at the front
- 1 TB RAID 1 internal; 0.5 g vibration, 5 g shock (2 × 1 TB HDD SATA, data mirroring)
- 1 TB RAID 1 in removable drive bay; for hot swapping; at the front, data mirroring (2 × 1 TB HDD SATA)
HDD (single station or server) - 1 TB RAID 1 in removable drive bay; for hot swapping; at the front, data mirroring (2 × 1 TB HDD SAS)
SSD (single station, server or client) - 240 GB or 480 GB SSD SATA internal
- 240 GB or 480 GB SSD SATA in removable drive bay; at the front
- RAID 1 SSD SATA in removable drive bay; for hot swapping; at the front, data mirroring; (single station or server)
- 240 GB (2 × 240 GB)
- 480 GB (2 × 480 GB)
HDD+SSD (single station or server) - 1 TB RAID 1 internal; 0.5 g vibration, 5 g shock (2 × 1 TB HDD SATA, data mirroring) plus 240 GB SSD SATA, internal, in the DVD drive slot
- 1 TB RAID1 in removable drive bay; for hot swapping; at the front, data mirroring (2 × 1 TB HDD SATA or 2 × 1 TB HDD SAS) plus 240 GB SSD SATA, internal, in the DVD drive slot
| HDD (single station or server) - 500 GB or 1 TB HDD SATA, internal; 0.5 g vibration, 5 g shock
- 500 GB or 1 TB HDD SATA in removable drive bay; at the front
- 1 TB RAID 1 internal; 0.5 g vibration, 5 g shock (2 × 1 TB HDD SATA, data mirroring)
- 1 TB RAID 1 in removable drive bay; for hot swapping; at the front, data mirroring (2 × 1 TB HDD SATA or 2 × 1 TB HDD SAS)
- 1 TB RAID 1 (2 × 1 TB HDD SATA, data mirroring) plus 1 TB hot-spare HDD SATA; each in removable drive bay; for hot swapping; at the front
- 2 TB RAID 5 in removable drive bay; for hot swapping; at the front, (3 × 1 TB HDD SAS, striping with parity)
- 2 TB RAID 5 (3 × 1 TB HDD SAS, striping with parity) plus 1 TB hot-spare HDD SAS; each in removable drive bay; for hot swapping; at the front
SSD (single station or server) - 240 GB or 480 GB SSD SATA internal
- 240 GB or 480 GB SSD SATA in removable drive bay; at the front
- RAID 1 SSD SATA in removable drive bay; for hot swapping; at the front, data mirroring
- 240 GB (2 × 240 GB)
- 480 GB (2 × 480 GB)
HDD+SSD (single station or server) - 1 TB RAID 1 internal; 0.5 g vibration, 5 g shock (2 × 1 TB HDD SATA, data mirroring) plus 240 GB SSD SATA, in removable drive bay, at the front
- 1 TB RAID 1 (2 × 1 TB HDD SATA or 2 × 1 TB HDD SAS; data mirroring, for hot swapping) plus 240 GB SSD SATA, each in removable drive bay; at the front
- 2 TB RAID 5 (3 × 1 TB HDD SAS, striping with parity, for hot swapping) plus 240 GB SSD SATA, each in removable drive bay; at the front
|
Graphics card | Onboard Intel graphics controller, integrated in processor; version depends on processor, either HD Graphics 530 (i7‑6700 and i5‑6500) or HD Graphics P530 (E3‑1275 v5) | Onboard Intel graphics controller HD Graphics P4600/P4700; 2‑D and 3‑D engine integrated in processor | Onboard Intel graphics controller HD Graphics P4600/P4700; 2‑D and 3‑D engine integrated in processor |
Graphics memory | Dynamic Video Memory Technology (uses between 32 MB and 1.7 GB RAM) | Dynamic Video Memory Technology (uses between 32 MB and 1.7 GB RAM) | Dynamic Video Memory Technology (uses between 32 MB and 1.7 GB RAM) |
Resolutions. frequencies, colors | | | |
| Up to 2560 × 1600 at 60 Hz, 32-bit color depth (DisplayPort to VGA via adapter cable) | Up to 2560 × 1600 at 120 Hz, 32-bit color depth (DVI‑I to VGA or DisplayPort to VGA via adapter cable) | Up to 2560 × 1600 at 120 Hz, 32-bit color depth (DVI‑I to VGA or DisplayPort to VGA via adapter cable) |
| Up to 1920 × 1200 at 60 Hz, 32-bit color depth | Up to 2048 × 1152 at 60 Hz, 32-bit color depth | Up to 2048 × 1152 at 60 Hz, 32-bit color depth |
| Up to 4096 × 2304 at 60 Hz, 32-bit color depth | Up to 4096 × 2160 at 24 Hz, 32-bit color depth | Up to 4096 × 2160 at 24 Hz, 32-bit color depth |
Interface modules, interfaces | | | |
Terminal bus interface | 2 × Ethernet port (RJ45) 10/100/1000 Mbps, teaming-capable, two independent controllers: Intel Jacksonville i219‑LM and Intel Springville i210‑AT | 2 × Ethernet port (RJ45) 10/100/1000 Mbps, electrically isolated, teaming-capable, two independent controllers: Intel WGI217LM and Intel WGI210IT | 2 × Ethernet port (RJ45) 10/100/1000 Mbps, electrically isolated, teaming-capable, two independent controllers: Intel WGI217LM and Intel WGI210IT |
Plant bus interface module (single station/server), alternatives | | | |
| Ethernet network adapter RJ45 10/100/1000 Mbps (PCIe x1) | Ethernet network adapter RJ45 10/100/1000 Mbps (PCIe x1) | Ethernet network adapter RJ45 10/100/1000 Mbps (PCIe x1) |
| CP 1623 communication module (PCIe x1) | CP 1623 communication module (PCIe x1) | CP 1623 communication module (PCIe x1) |
USB 3.0 | 6 channels, 900 mA high current (≤ 3 A in total), super speed - 4 × at rear
- 2 × at front
| 4 channels, 500 mA high current, super speed - 2 × at rear
- 1 × at front
- 1 × internal, with mechanical locking, e.g. for USB dongle
| 4 channels, 500 mA high current, super speed - 2 × at rear
- 1 × at front
- 1 × internal, with mechanical locking, e.g. for USB dongle
|
USB 2.0 | 5 channels, 500 mA high current, high speed - 4 × at rear
- 1 × internal, with mechanical locking, e.g. for USB dongle
| 3 channels, 500 mA high current, high speed - 2 × at rear
- 1 × at front
| 3 channels, 500 mA high current, high speed - 2 × at rear
- 1 × at front
|
Serial (COM) | 1 × COM1 (V.24), 9‑pin sub‑D female connector | 1 × COM1 (V.24), 9‑pin sub‑D male connector | 1 × COM1 (V.24), 9‑pin sub‑D male connector |
Audio | Realtek ALC671, 6‑channel DAC support; 1 × Line In; 1 × Micro In; 1 × Line Out (2 W into 4 Ω) | 1 × Micro In; 1 × Line Out/headphones (2 × 0.5 W/8 Ω); IDT 92HD81HD | 1 × Micro In; 1 × Line Out/headphones (2 × 0.5 W/8 Ω); IDT 92HD81HD |
DisplayPort | Yes, 2 × | Yes, 2 × | Yes, 2 × |
DVI | 1 × DVI‑D for digital connection of a monitor | 1 × DVI-I for digital connection of a monitor | 1 × DVI-I for digital connection of a monitor |
Multi-monitor interface | 2 monitors: Integral interfaces: 1 × DVI and 1 × DVI via DisplayPort DVI adapter or 2 × via DisplayPort 3 or 4 monitors: Onboard interfaces (2 × DisplayPort) + Dual Head PCIe x16 graphics card (2 × DisplayPort) combined, DVI via additional adapter cable | 2 monitors: Integral interfaces: 1 × DVI and 1 × DVI via DisplayPort DVI adapter 3 or 4 monitors: Onboard interfaces (2 × DisplayPort) + Dual Head PCIe x16 graphics card (2 × DisplayPort) combined, DVI via additional adapter cable | 2 monitors: Integral interfaces: 1 × DVI and 1 × DVI via DisplayPort DVI adapter 3 or 4 monitors: Onboard interfaces (2 × DisplayPort) + Dual Head PCIe x16 graphics card (2 × DisplayPort) combined, DVI via additional adapter cable |
Keyboard | 1 × PS/2 | 1 × PS/2 | 1 × PS/2 |
Mouse | 1 × PS/2 | 1 × PS/2 | 1 × PS/2 |
Operating systems and diagnostics software | | | |
ES/OS single station | Windows 10 IoT Enterprise LTSB 2015 64-bit, multi-language (English, German, French, Italian, Spanish, Chinese) | Windows 10 IoT Enterprise LTSB 2015 64-bit, multi-language (English, German, French, Italian, Spanish, Chinese) | Windows 10 IoT Enterprise LTSB 2015 64-bit, multi-language (English, German, French, Italian, Spanish, Chinese) |
OS server | Windows Server 2012 R2 Standard 64-bit including 5 CAL, multi-language (German, English, French, Italian, Spanish, Chinese) | Windows Server 2012 R2 Standard 64-bit including 5 CAL, multi-language (German, English, French, Italian, Spanish, Chinese) | Windows Server 2012 R2 Standard 64-bit including 5 CAL, multi-language (German, English, French, Italian, Spanish, Chinese) |
OS client | Windows 10 IoT Enterprise LTSB 2015 64-bit, multi-language (English, German, French, Italian, Spanish, Chinese) | Windows 10 IoT Enterprise LTSB 2015 64-bit, multi-language (English, German, French, Italian, Spanish, Chinese) | -- |
System tested SIMATIC Industrial Software | SIMATIC IPC DiagMonitor integrated in pre-installation | SIMATIC IPC DiagMonitor integrated in pre-installation | SIMATIC IPC DiagMonitor integrated in pre-installation |
Monitoring and diagnostics functions | | | |
Watchdog | - Monitoring of program execution
- Monitoring time adjustable in the software
- Restart can be configured for faults
| - Monitoring of program execution
- Monitoring time adjustable in the software
- Restart can be configured for faults
| - Monitoring of program execution
- Monitoring time adjustable in the software
- Restart can be configured for faults
|
Temperature | High/low violation of permitted operating temperature | Violation of permissible operating temperature | Violation of permissible operating temperature |
Fans | Speed monitoring for - Front fan
- Processor fan
- Fan on drive cage
- Fan of single, non-redundant power supply
| Speed monitoring for - Front fan
- Processor fan
- Power supply fan
| Speed monitoring for - Front fan
- Processor fan
- Power supply fan
|
Battery | Two-stage monitoring; service life following first warning at least 1 month | Two-stage monitoring; service life following first warning at least 1 month | Two-stage monitoring; service life following first warning at least 1 month |
Drives | SMART messages of hard disks; RAID states "Normal", "Degraded" and "Rebuild" | SMART messages of hard disks; RAID states "Normal", "Degraded" and "Rebuild" | SMART messages of hard disks; RAID states "Normal", "Degraded" and "Rebuild" |
Indicators (front LEDs) | - POWER (operating state)
- TEMP (temperature status)
- FAN (fan status)
- HDD (hard disk activity)
- HDD0/1/2/3 alarm (RAID status messages)
| - POWER (device switched on)
- HDD (hard disk activity)
- ETHERNET 1, ETHERNET 2 (Ethernet status)
- WATCHDOG (ready/fault signal)
- TEMP (temperature status)
- FAN (fan/temperature monitoring)
- HDD0/1 ALARM (RAID status messages)
| - POWER (device switched on)
- ETHERNET 1, ETHERNET 2 (Ethernet status)
- WATCHDOG (ready/fault signal)
- TEMP (temperature status)
- FAN (fan/temperature monitoring)
- HDD0/1/2 ALARM (RAID status messages) and HDD | HDD3 ALARM (hard disk activity and RAID status message)
|
Safety | | | |
Protection class | Protection class I in accordance with IEC 61140 | Protection class I in accordance with IEC 61140 | Protection class I in accordance with IEC 61140 |
Safety directives | IEC 60950-1; EN 60950-1; UL 60950-1; CSA C22.2 No. 60950‑1‑07 | IEC 60950-1; EN 60950-1; UL 60950-1; CSA C22.2 No 60950‑1‑07 | IEC 60950-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950‑1‑07 |
Noise emission | | | |
Operation | < 45 dB(A) according to DIN 45635 (40 dB(A) at 20 °C and Windows idle mode) | < 45 dB(A) at 25 °C according to EN ISO 7779 (without DVD drive) | < 55 dB(A) at 25 °C according to EN ISO 7779 (all drives in operation; high CPU loading) < 45 dB(A) at 25 °C according to EN ISO 7779 (without DVD drive; low CPU loading) |
Electromagnetic compatibility (EMC) | | | |
Interference emission | EN 61000‑6‑3; EN 61000‑6‑4 CISPR 22, EN 55022 Class B; FCC Class A / EN 61000‑3‑2 Class D; EN 61000‑3‑3 | EN 61000‑6‑3, FCC Class A; EN 61000‑6‑4; CISPR 22, EN 55022 Class B; EN 61000‑3‑2 Class D and EN 61000‑3‑3 | EN 61000‑6‑3, FCC Class A; EN 61000‑6‑4; CISPR 22, EN 55022 Class B; EN 61000‑3‑2 Class D and EN 61000‑3‑3 |
Immunity to conducted interference on the supply lines | ±2 kV (to IEC 61000‑4‑4, burst) ±1 kV (to IEC 61000‑4‑5, symmetrical surge) ±2 kV (to IEC 61000‑4‑5, asymmetrical surge) | ±2 kV (to IEC 61000‑4‑4; burst) ±1 kV (to IEC 61000‑4‑5; symmetrical surge) ±2 kV (to IEC 61000‑4‑5; asymmetrical surge) | ±2 kV (to IEC 61000‑4‑4; burst) ±1 kV (to IEC 61000‑4‑5; symmetrical surge) ±2 kV (to IEC 61000‑4‑5; asymmetrical surge) |
Immunity to interference on signal lines | ±1 kV (to IEC 61000‑4‑4; burst; length < 30 m) ±2 kV (to IEC 61000‑4‑4; burst; length > 30 m) ±2 kV (to IEC 61000‑4‑5; surge; length > 30 m) | ±1 kV (to IEC 61000‑4‑4; burst; length < 30 m) ±2 kV (to IEC 61000‑4‑4; burst; length > 30 m) ±2 kV (to IEC 61000‑4‑5; length > 30 m) | ±1 kV (to IEC 61000‑4‑4; burst; length < 30 m) ±2 kV (to IEC 61000‑4‑4; burst; length > 30 m) ±2 kV (to IEC 61000‑4‑5; surge; length > 30 m) |
Immunity to static discharge | ±4 kV contact discharge (according to IEC 61000‑4‑2) ±8 kV atmospheric discharge (according to IEC 61000‑4‑2) | ±6 kV contact discharge (according to IEC 61000‑4‑2) ±8 kV atmospheric discharge (according to IEC 61000‑4‑2) | ±6 kV contact discharge (according to IEC 61000‑4‑2) ±8 kV atmospheric discharge (according to IEC 61000‑4‑2) |
Immunity to radio frequency interference | 1 V/m, 2 … 2.7 GHz, 80% AM (to IEC 61000‑4‑3) 3 V/m, 1.4 … 2 GHz, 80% AM (to IEC 61000‑4‑3) 10 V/m, 80 … 1000 MHz, 80% AM (to IEC 61000‑4‑3) 10 V, 150 kHz … 80 MHz, 80% AM (to IEC 61000‑4‑6) | 3 V/m, 2 … 2.7 GHz, 80 % AM (to IEC 61000‑4‑3) 10 V/m, 80 … 1 000 MHz and 1.4 … 2 GHz, 80 % AM (to IEC 6100‑4‑3) 10 V, 10 kHz ... 80 MHz, 80 % AM (to IEC 61000‑4‑6) | 3 V/m, 2 … 2.7 GHz, 80 % AM (to IEC 61000‑4‑3) 10 V/m, 80 … 1 000 MHz and 1.4 … 2 GHz, 80 % AM (to IEC 6100‑4‑3) 10 V, 10 kHz ... 80 MHz, 80 % AM (to IEC 61000‑4‑6) |
Magnetic field | 30 A/m, 50 Hz/60 Hz (according to IEC 61000‑4‑8) | 100 A/m, 50 Hz/60 Hz (to IEC 61000‑4‑8) | 100 A/m, 50 Hz/60 Hz (to IEC 61000‑4‑8) |
Climatic conditions | | | |
Temperature | Tested according to IEC 60068‑2‑2, IEC 60068‑2‑1, IEC 60068‑2‑14 | Tested according to IEC 60068‑2‑2, IEC 60068‑2-1, IEC 60068‑2‑14 | Tested according to IEC 60068‑2‑2, IEC 60068‑2‑1, IEC 60068‑2‑14 |
| +5 … +35 °C (without restriction) 0 to +40 °C (no DVD burner operation)1) Gradient: ≤ 10 K/h, no condensation 1) Power dissipation of the expansion modules in total max. 80 W | +0 to +35 °C (without restriction) 0 to +40 °C (without hardware RAID controller)1) 0 to +45 °C (without DVD burner, without hardware RAID controller)1) 0 to +50 °C (without DVD burner, without hardware RAID controller, no HDD operation in removable drive bay) Gradient: max. 10 °C/h, no condensation 1) Power dissipation of the expansion modules in total max. 55 W | 0 to +35 °C (with hardware RAID controller) 0 to +45 °C (without DVD burner) 0 to +50 °C (without DVD burner, max. 3 removable drive bays)1) Gradient: max. 10 °C/h, no condensation 1) Power dissipation of the expansion modules in total max. 30 W |
| -20 … +60 °C Gradient: max. 2 K/h, no condensation | -20 … +60 °C Gradient: max. 20 °C/h, no condensation | -20 … +60 °C Gradient: max. 20 °C/h, no condensation |
Relative humidity | Tested according to IEC 60068‑2‑78, IEC 60068‑2‑30 | Tested according to IEC 60068‑2‑78, IEC 60068‑2‑30 | Tested according to IEC 60068‑2‑78, IEC 60068‑2‑30 |
| 5 ... 85% at 30 °C (no condensation) Gradient: max. 10 K/h (no condensation) | 5 … 80 % at 25 °C (no condensation) Gradient: max. 10 °C/h (no condensation) | 5 … 80 % at 25 °C (no condensation) Gradient: max. 10 °C/h (no condensation) |
| 5 ... 95% at 25 ... 55 °C (no condensation) Gradient: ≤ 20 K/h (no condensation) | 5 … 95 % at 25 °C (no condensation) Gradient: max. 20 °C/h (no condensation) | 5 … 95 % at 25 °C (no condensation) Gradient: max. 20 °C/h (no condensation) |
Atmospheric pressure | | | |
| 1080 ... 689 hPa (corresponds to a height of ‑1 000 ... 3 000 m) | 1080 ... 795 hPa (corresponds to a height of ‑1 000 ... 2 000 m) | 1080 ... 795 hPa (corresponds to a height of ‑1 000 ... 2 000 m) |
| 1080 ... 660 hPa (corresponds to a height of ‑1 000 ... 3 500 m) | 1080 ... 660 hPa (corresponds to a height of ‑1 000 ... 3 500 m) | 1080 ... 660 hPa (corresponds to a height of ‑1 000 ... 3 500 m) |
Mechanical environmental conditions | | | |
Vibrations | Tested according to IEC 60068‑2‑6, 10 cycles | Tested according to IEC 60068‑2‑6, 10 cycles | Tested according to IEC 60068‑2‑6, 10 cycles |
| 20 … 58 Hz: Amplitude 0.015 mm; 58 … 200 Hz: 2 m/s² (approx. 0.2 g) Note: No mechanical loads when using hard disks in removable trays and during DVD burning process. | 10 … 58 Hz: Amplitude 0.0375 mm; 58 ... 500 Hz: 4.9 m/s² (approx. 0.5 g) Note: No mechanical loads when using hard disks in removable drive bay and during DVD burning process. | 10 … 58 Hz: Amplitude 0.0375 mm1); 58 ... 500 Hz: 4.9 m/s² (approx. 0.5 g)1) Note: No mechanical loads when using hard disks in removable drive bay and during DVD burning process. 1) With HDD mounting on side panel and assembly of device using telescopic rails max. 0.019 mm at 10 … 58 Hz; max. 3 m/s² at 58 … 500 Hz |
| 5 … 8.51 Hz: Amplitude 3.5 mm; 8.51 … 500 Hz: 9.8 m/s² | 5 … 9 Hz: Amplitude 3.5 mm; 9 … 500 Hz: 9.8 m/s² | 5 … 9 Hz: Amplitude 3.5 mm; 9 … 500 Hz: 9.8 m/s² |
Shock resistance | Tested according to IEC 60068‑2‑27 | Tested according to IEC 60068‑2‑27, IEC 60068‑2‑29 | Tested according to IEC 60068‑2‑27, IEC 60068‑2‑29 |
| Half sine: 9.8 m/s², 20 ms (approx. 1 g), 100 shocks per axis Note: No mechanical loads when using hard disks in removable trays and during DVD burning process. | Half sine: 50 m/s², 30 ms (approx. 5 g), 100 shocks per axis Note: No mechanical loads when using hard disks in removable drive bay and during DVD burning process. | Half sine: 50 m/s², 30 ms (approx. 5 g), 100 shocks per axis1) Note: No mechanical loads when using hard disks in removable drive bay and during DVD burning process. 1) With HDD mounting on side panel and assembly of device using telescopic rails max. 0.019 mm at 10 … 58 Hz; max. 3 m/s² at 58 … 500 Hz |
| Half sine: 250 m/s², 6 ms, 1000 shocks per axis | Half sine: 250 m/s², 6 ms, 1000 shocks per axis | Half sine: 250 m/s², 6 ms, 1000 shocks per axis |
Approvals, standards | | | |
CE in conformity with 2004/108/EC, 2006/95/EC | Yes | Yes | Yes |
Industrial area of application | | | |
| EN 61000‑6‑4:2007 + A1:2011 | EN 61000‑6‑4:2007 + A1:2011 | EN 61000‑6‑4:2007 + A1:2011 |
| EN 61000‑6‑2:2005 | EN 61000‑6‑2:2005 | EN 61000‑6‑2:2005 |
Area of application: Residential, business, trade, small enterprise | | | |
| EN 61000‑6‑3:2007 + A1:2011 | EN 61000‑6‑3:2007 + A1:2011 | EN 61000‑6‑3:2007 + A1:2011 |
| EN 61000‑6‑1:2007 | EN 61000‑6‑1:2007 | EN 61000‑6‑1:2007 |
cULus: - 60950‑1, File No. E11 5352
- CAN/CSA-C22.2 No. 60950‑1‑07 (I.T.E.)
| Yes | Yes | Yes |
USA: FCC Rules, Part 15, Class A | Yes | Yes | Yes |
Canada: ICES-003, Class B; NMB‑003, Class B | Yes | Yes | Yes |
Australia/New Zealand: EN 61000‑6‑3:2007 | Yes | Yes | Yes |
Korea: Korean Certification (KC Mark) | Yes | Yes | Yes |
EAC (Eurasian Conformity) | Yes | Yes | Yes |
Special features | | | |
Quality assurance according to ISO 9001:2008 | Yes | Yes | Yes |
Power supply | | | |
Nominal supply voltage (UN) | Single power supply unit: - 100 … 240 V AC (‑15%, +10%)
Redundant power supply unit: - 2 × 100 … 240 V AC (‑15%, +10%)
| Single power supply unit: - 100 … 240 V AC (‑15%, +10%)
Redundant power supply unit: - 2 × 100 … 240 V AC (‑15%, +10%)
| Single power supply unit: - 100 … 240 V AC (‑15%, +10%)
Redundant power supply unit: - 2 × 100 … 240 V AC (‑15%, +10%)
|
Frequency | 50 … 60 Hz (min. 47 Hz, max. 63 Hz, sinusoidal) | 50 … 60 Hz (min. 47 Hz, max. 63 Hz, sinusoidal) | 50 … 60 Hz (min. 47 Hz, max. 63 Hz, sinusoidal) |
Short-term voltage dip | - 20 ms for 230 W
(max. 10 events per hour; recovery time ≥ 1 s) with single power supply unit - 20 ms for 240 W
(≤ 10 events per hour; recovery time ≥ 1 s) with redundant power supply unit
| 20 ms at 93 V (max. 10 events per hour; min. recovery time 1 s) | 20 ms at 93 V (max. 10 events per hour; min. recovery time 1 s) |
Power consumption at 230 W secondary (maximum configuration) | - 260 W max. at 90% efficiency with single power supply unit
- 270 W max. at 85% efficiency with redundant power supply unit
| 240 W max. at 80 % efficiency with single or redundant power supply unit | - 270 W max. at 80 % efficiency with single power supply unit
- 300 W max. at 70 % efficiency with redundant power supply unit
|
AC input current | Single power supply unit: - Continuous current up to 6 A at 100 V; up to 3 A at 240 V
- Up to 80 A for 3.6 ms during startup
Redundant power supply unit: - Continuous current up to 5 A at 100 V; up to 2.5 A at 240 V
- Up to 210 A per module for 1.65 ms during startup
| - Continuous current up to 6 A
- Up to 30 A for 5 ms during startup
| - Continuous current up to 7 A
- Up to 30 A for 5 ms during startup
|
Max. current output (DC) | Single power supply unit: - +5 V: 25 A; +3.3 V: 20 A (in total up to 190 W)
- +12 V: 14 A; +12 V: 11 A
- -12 V: 0.1 A
- +5 Vaux: 2 A
Redundant power supply unit: - +5 V: 20 A; +3.3 V: 20 A (in total up to 100 W)
- +12 V: 16 A; +12 V: 16 A
- -12 V: 0.5 A
- +5 Vaux: 3 A
Total sum of all voltages max. 230 W | - +5 V: 30 A; +3.3 V: 28 A (in total up to 160 W)
- +12 V: 15 A
- -12 V: 0.5 A
- -5 V: 0.5 A
- +5 Vaux: 2 A
Total sum of all voltages max. 190 W | - +5 V: 26 A; +3.3 V: 24 A (in total up to 190 W)
- +12 V: 15 A; +12 V: 15 A
- -12 V: 0.2 A
- +5 Vaux: 2 A
Total sum of all voltages max. 210 W |
Dimensions and weights | | | |
Installation dimensions (W × H × D) in mm | 433.5 × 176.5 × 445.5 | 430.4 × 88.1 × 444.6 | 430.4 × 177.4 × 444.4 |
Weight (depending on configuration) | 15 … 23 kg | 10 … 14 kg | 16 … 23 kg |