General information | | | |
Product type designation | CPU 1211C AC/DC/relay | CPU 1211C DC/DC/DC | CPU 1211C DC/DC/relay |
Firmware version | V4.2 | V4.2 | V4.2 |
Engineering with | | | |
| STEP 7 V14 or higher | STEP 7 V14 or higher | STEP 7 V14 or higher |
Supply voltage | | | |
Rated value (DC) | | | |
| | Yes | Yes |
permissible range, lower limit (DC) | | 20.4V | 20.4V |
permissible range, upper limit (DC) | | 28.8V | 28.8V |
Rated value (AC) | | | |
| Yes | | |
| Yes | | |
permissible range, lower limit (AC) | 85V | | |
permissible range, upper limit (AC) | 264V | | |
Reverse polarity protection | | Yes | Yes |
Line frequency | | | |
| 47Hz | | |
| 63Hz | | |
Load voltage L+ | | | |
| | 24V | 24V |
| | 20.4V | 20.4V |
| | 28.8V | 28.8V |
Input current | | | |
Current consumption (rated value) | 60 mA at 120 V AC; 30 mA at 240 V AC | 300mA; CPU only | 300mA; CPU only |
Current consumption, max. | 180 mA at 120 V AC; 90 mA at 240 V AC | 900mA; CPU with all expansion modules | 900mA; CPU with all expansion modules |
Inrush current, max. | 20A; at 264 V | 12A; at 28.8 V DC | 12A; at 28.8 V DC |
It | 0.8As | 0.5As | 0.8As |
Output current | | | |
for backplane bus (5 V DC), max. | 750mA; Max. 5 V DC for CM | 750mA; Max. 5 V DC for CM | 750mA; Max. 5 V DC for CM |
Encoder supply | | | |
24 V encoder supply | | | |
| 20.4 to 28.8V | L+ minus 4 V DC min. | L+ minus 4 V DC min. |
Power loss | | | |
Power loss, typ. | 10W | 8W | 8W |
Memory | | | |
Work memory | | | |
| 50kbyte | 50kbyte | 50kbyte |
| No | No | No |
Load memory | | | |
| 1Mbyte | 1Mbyte | 1Mbyte |
| with SIMATIC memory card | with SIMATIC memory card | with SIMATIC memory card |
Backup | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
CPU processing times | | | |
for bit operations, typ. | 0.08s; / instruction | 0.08s; / instruction | 0.08s; / instruction |
for word operations, typ. | 1.7s; / instruction | 1.7s; / instruction | 1.7s; / instruction |
for floating point arithmetic, typ. | 2.3s; / instruction | 2.3s; / instruction | 2.3s; / instruction |
CPU-blocks | | | |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB | | | |
| Limited only by RAM for code | Limited only by RAM for code | Limited only by RAM for code |
Data areas and their retentivity | | | |
Retentive data area (incl. timers, counters, flags), max. | 10kbyte | 10kbyte | 10kbyte |
Flag | | | |
| 4kbyte; Size of bit memory address area | 4kbyte; Size of bit memory address area | 4kbyte; Size of bit memory address area |
Local data | | | |
| 16kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | 16kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | 16kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Process image | | | |
| 1kbyte | 1kbyte | 1kbyte |
| 1kbyte | 1kbyte | 1kbyte |
Hardware configuration | | | |
Number of modules per system, max. | 3 communication modules, 1 signal board | 3 communication modules, 1 signal board | 3 communication modules, 1 signal board |
Time of day | | | |
Clock | | | |
| Yes | Yes | Yes |
| 480h; Typical | 480h; Typical | 480h; Typical |
| 60 s/month at 25 C | 60 s/month at 25 C | 60 s/month at 25 C |
Digital inputs | | | |
Number of digital inputs | 6; Integrated | 6; Integrated | 6; Integrated |
| 3; HSC (High Speed Counting) | 3; HSC (High Speed Counting) | 3; HSC (High Speed Counting) |
Source/sink input | Yes | Yes | Yes |
Number of simultaneously controllable inputs | | | |
all mounting positions | | | |
| 6 | 6 | 6 |
Input voltage | | | |
| 24V | 24V | 24V |
| 5 V DC at 1 mA | 5 V DC at 1 mA | 5 V DC at 1 mA |
| 15 V DC at 2.5 mA | 15 V DC at 2.5 mA | 15 V DC at 2.5 mA |
Input current | | | |
| 4mA; nominal | 4mA; nominal | 4mA; nominal |
Input delay (for rated value of input voltage) | | | |
for standard inputs | | | |
| 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms | 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
| 0.2ms | 0.2ms | 0.2ms |
| 12.8ms | 12.8ms | 12.8ms |
for interrupt inputs | | | |
| Yes | Yes | Yes |
for counter/technological functions | | | |
| Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz |
Cable length | | | |
| 500m; 50 m for technological functions | 500m; 50 m for technological functions | 500m; 50 m for technological functions |
| 300m; For technological functions: No | 300m; For technological functions: No | 300m; For technological functions: No |
Digital outputs | | | |
Number of digital outputs | 4; Relays | 4 | 4; Relays |
| | 4; 100 kHz Pulse Train Output | |
Limitation of inductive shutdown voltage to | | L+ (-48 V) | |
Switching capacity of the outputs | | | |
| 2A | 0.5A | 2A |
| 30 W with DC, 200 W with AC | 5W | 30 W with DC, 200 W with AC |
Output voltage | | | |
| | 0.1V; with 10 kOhm load | |
| | 20 V | |
Output current | | | |
| | 0.5A | |
| | 0.1mA | |
Output delay with resistive load | | | |
| 10ms; max. | 1s | 10ms; max. |
| 10ms; max. | 5s | 10ms; max. |
Switching frequency | | | |
| | 100kHz | |
Relay outputs | | | |
| mechanically 10 million, at rated load voltage 100 000 | | mechanically 10 million, at rated load voltage 100 000 |
Cable length | | | |
| 500m | 500m | 500m |
| 150m | 150m | 150m |
Analog inputs | | | |
Number of analog inputs | 2 | 2 | 2 |
Input ranges | | | |
| Yes | Yes | Yes |
Input ranges (rated values), voltages | | | |
| Yes | Yes | Yes |
| ≥100k ohms | ≥100k ohms | ≥100k ohms |
Cable length | | | |
| 100m; twisted and shielded | 100m; twisted and shielded | 100m; twisted and shielded |
Analog outputs | | | |
Number of analog outputs | 0 | 0 | 0 |
Analog value generation for the inputs | | | |
Integration and conversion time/resolution per channel | | | |
| 10bit | 10bit | 10bit |
| Yes | Yes | Yes |
| 625s | 625s | 625s |
Encoder | | | |
Connectable encoders | | | |
| Yes | Yes | Yes |
1. Interface | | | |
Interface type | PROFINET | PROFINET | PROFINET |
Physics | Ethernet | Ethernet | Ethernet |
Isolated | Yes | Yes | Yes |
automatic detection of transmission rate | Yes | Yes | Yes |
Autonegotiation | Yes | Yes | Yes |
Autocrossing | Yes | Yes | Yes |
Interface types | | | |
| 1 | 1 | 1 |
| No | No | No |
Functionality | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
PROFINET IO Controller | | | |
| 100Mbit/s | 100Mbit/s | 100Mbit/s |
Services | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
| 16 | 16 | 16 |
| 16 | 16 | 16 |
| 16 | 16 | 16 |
| 16 | 16 | 16 |
| Yes | Yes | Yes |
| 8 | 8 | 8 |
| The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
PROFINET IO Device | | | |
Services | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
| No | No | No |
| No | No | No |
| No | No | No |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| 2 | 2 | 2 |
Protocols | | | |
Supports protocol for PROFINET IO | Yes | Yes | Yes |
PROFIBUS | Yes; CM 1243-5 required | Yes; CM 1243-5 required | Yes; CM 1243-5 required |
AS-Interface | Yes; CM 1243-2 required | Yes; CM 1243-2 required | Yes; CM 1243-2 required |
Protocols (Ethernet) | | | |
| Yes | Yes | Yes |
| No | No | No |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Open IE communication | | | |
| Yes | Yes | Yes |
| 8kbyte | 8kbyte | 8kbyte |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| 8kbyte | 8kbyte | 8kbyte |
| Yes | Yes | Yes |
| 1472byte | 1472byte | 1472byte |
Web server | | | |
| Yes | Yes | Yes |
Further protocols | | | |
| Yes | Yes | Yes |
Communication functions | | | |
S7 communication | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| See online help (S7 communication, user data size) | See online help (S7 communication, user data size) | See online help (S7 communication, user data size) |
Web server | | | |
| Yes | Yes | Yes |
Number of connections | | | |
| 16; dynamically | 16; dynamically | 16; dynamically |
Test commissioning functions | | | |
Status/control | | | |
| Yes | Yes | Yes |
| Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing | | | |
| Yes | Yes | Yes |
Diagnostic buffer | | | |
| Yes | Yes | Yes |
Traces | | | |
| 2 | 2 | 2 |
| 512kbyte | 512kbyte | 512kbyte |
Interrupts/diagnostics/status information | | | |
Diagnostics indication LED | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Integrated Functions | | | |
Number of counters | 3 | 6 | 3 |
Counting frequency (counter) max. | 100kHz | 100kHz | 100kHz |
Frequency measurement | Yes | Yes | Yes |
controlled positioning | Yes | Yes | Yes |
Number of position-controlled positioning axes, max. | 8 | 8 | 8 |
Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 | 4; With integrated outputs | Up to 4 with SB 1222 |
PID controller | Yes | Yes | Yes |
Number of alarm inputs | 4 | 4 | 4 |
Number of pulse outputs | | 4 | |
Limit frequency (pulse) | | 100kHz | |
Potential separation | | | |
Potential separation digital inputs | | | |
| 500V AC for 1 minute | No | 500V AC for 1 minute |
| 1 | 1 | 1 |
Potential separation digital outputs | | | |
| Relays | Yes | Relays |
| No | No | No |
| 1 | 1 | 1 |
EMC | | | |
Interference immunity against discharge of static electricity | | | |
| Yes | Yes | Yes |
| 8kV | 8kV | 8kV |
| 6kV | 6kV | 6kV |
Interference immunity to cable-borne interference | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Interference immunity against voltage surge | | | |
| Yes | Yes | Yes |
Interference immunity against conducted variable disturbance induced by high-frequency fields | | | |
| Yes | Yes | Yes |
Emission of radio interference acc. to EN 55 011 | | | |
| Yes; Group 1 | Yes; Group 1 | Yes; Group 1 |
| Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection | | | |
Degree of protection acc. to EN 60529 | | | |
| Yes | Yes | Yes |
Standards, approvals, certificates | | | |
CE mark | Yes | Yes | Yes |
UL approval | Yes | Yes | Yes |
cULus | Yes | Yes | Yes |
FM approval | Yes | Yes | Yes |
RCM (formerly C-TICK) | Yes | Yes | Yes |
KC approval | Yes | Yes | Yes |
Marine approval | Yes | Yes | Yes |
Ambient conditions | | | |
Free fall | | | |
| 0.3m; five times, in product package | 0.3m; five times, in product package | 0.3m; five times, in product package |
Ambient temperature during operation | | | |
| -20C | -20C | -20C |
| 60C | 60C | 60C |
| -20C | -20C | -20C |
| 60C | 60C | 60C |
| -20C | -20C | -20C |
| 50C | 50C | 50C |
Ambient temperature during storage/transportation | | | |
| -40C | -40C | -40C |
| 70C | 70C | 70C |
Air pressure acc. to IEC 60068-2-13 | | | |
| 795hPa | 795hPa | 795hPa |
| 1080hPa | 1080hPa | 1080hPa |
| 660hPa | 660hPa | 660hPa |
| 1080hPa | 1080hPa | 1080hPa |
| -1000m | -1000m | -1000m |
| 2000m | 2000m | 2000m |
Relative humidity | | | |
| 95%; no condensation | 95%; no condensation | 95%; no condensation |
Vibrations | | | |
| 2 g (m/s) wall mounting, 1 g (m/s) DIN rail | 2 g (m/s) wall mounting, 1 g (m/s) DIN rail | 2 g (m/s) wall mounting, 1 g (m/s) DIN rail |
| Yes | Yes | Yes |
Shock testing | | | |
| Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations | | | |
| S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
Programming | | | |
Programming language | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Know-how protection | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Access protection | | | |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
Cycle time monitoring | | | |
| Yes | Yes | Yes |
Dimensions | | | |
Width | 90mm | 90mm | 90mm |
Height | 100mm | 100mm | 100mm |
Depth | 75mm | 75mm | 75mm |
Weights | | | |
Weight, approx. | 420g | 370g | 380g |