Article number | 6ES7141-6BF00-0AB0 | 6ES7141-6BG00-0AB0 | 6ES7141-6BH00-0AB0 |
|---|
| ET200ECO PN, 8DI, DC24V, 4XM12 | ET200ECO PN, 8DI, DC24V, 8XM12 | ET200ECO PN, 16DI, DC24V, 8XM12 |
|---|
General information | | | | Vendor identification (VendorID) | 002AH | 002AH | 002AH | Device identifier (DeviceID) | 0306H | 0306H | 0306H | Supply voltage | | | | Rated value (DC) | 24V | 24V | 24V | permissible range, lower limit (DC) | 20.4V | 20.4V | 20.4V | permissible range, upper limit (DC) | 28.8V | 28.8V | 28.8V | Reverse polarity protection | Yes | Yes | Yes | Input current | | | | Current consumption, typ. | 100mA | 100mA | 100mA | Encoder supply | | | | Number of outputs | 4 | 8 | 8 | Short-circuit protection | Yes; Electronic | Yes; Electronic | Yes; Electronic | Output current | | | | | 100mA; per output | 100mA; per output | 100mA; per output | Power loss | | | | Power loss, typ. | 5.5W | 4.5W | 6.5W | Digital inputs | | | | Number of digital inputs | 8 | 8 | 16 | | 2 | 1 | 2 | Input characteristic curve in accordance with IEC 61131, type 3 | Yes | Yes | Yes | Number of simultaneously controllable inputs | | | | all mounting positions | | | | | 8 | 8 | 16 | Input voltage | | | | | DC | DC | DC | | 24V | 24V | 24V | | -3 to +5V | -3 to +5V | -3 to +5V | | +11 to +30V | +11 to +30V | +11 to +30V | Input current | | | | | 7mA | 7mA | 7mA | Input delay (for rated value of input voltage) | | | | for standard inputs | | | | | typically 3 ms | typically 3 ms | typically 3 ms | | typically 3 ms | typically 3 ms | typically 3 ms | Cable length | | | | | 30m | 30m | 30m | Encoder | | | | Connectable encoders | | | | | Yes | Yes | Yes | | 1.5mA | 1.5mA | 1.5mA | Interfaces | | | | Transmission procedure | 100BASE-TX | 100BASE-TX | 100BASE-TX | Number of PROFINET interfaces | 1 | 1 | 1 | PROFINET IO | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | | 100Mbit/s | 100Mbit/s | 100Mbit/s | | Yes | Yes | Yes | Protocols | | | | Supports protocol for PROFINET IO | Yes | Yes | Yes | PROFINET CBA | No | No | No | PROFIsafe | No | No | No | Protocols (Ethernet) | | | | | No | No | No | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | | Yes | Yes | Yes | PROFINET IO Device | | | | Services | | | | | Yes | Yes | Yes | | Yes | Yes | Yes | Interrupts/diagnostics/status information | | | | Status indicator | Yes; Green LED | Yes; Green LED | Yes; Green LED | Diagnostic functions | Yes | Yes | Yes | Alarms | | | | | Yes | Yes | Yes | Diagnostic messages | | | | | Yes | Yes | Yes | | Yes; Green "ON" LED | Yes; Green "ON" LED | Yes; Green "ON" LED | | Yes | Yes | Yes | | Yes; Per channel group | Yes; Per channel group | Yes; Per channel group | | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Potential separation | | | | between the load voltages | Yes | Yes | Yes | between load voltage and all other switching components | No | No | No | between Ethernet and electronics | Yes | Yes | Yes | Potential separation digital inputs | | | | | No | No | No | Isolation | | | | tested with | | | | | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | Degree and class of protection | | | | IP degree of protection | IP65/67 | IP67 | IP67 | Connection method | | | | Design of electrical connection | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | Dimensions | | | | Width | 30mm | 60mm | 60mm | Height | 200mm | 175mm | 175mm | Depth | 49mm | 49mm | 49mm | Weights | | | | Weight (without packaging) | 550g | 910g | 910g |
Article number | 6ES7142-6BF50-0AB0 | 6ES7142-6BF00-0AB0 | 6ES7142-6BG00-0AB0 | 6ES7142-6BR00-0AB0 | 6ES7142-6BH00-0AB0 |
|---|
| ET200ECO PN, 8DO, DC24V/0,5A, 4XM12 | ET200ECO PN, 8DO, DC24V/1,3A, 4XM12 | ET200ECO PN, 8DO, DC24V/1,3A, 8XM12 | ET200ECO PN, 8 DO, DC24V/2A, 8XM12 | ET200ECO PN, 16DO DC24V/1,3A, 8XM12 |
|---|
General information | | | | | | Vendor identification (VendorID) | 002AH | 002AH | 002AH | 002AH | 002AH | Device identifier (DeviceID) | 0306H | 0306H | 0306H | 0306H | 0306H | Supply voltage | | | | | | Rated value (DC) | 24V | 24V | 24V | 24V | 24V | permissible range, lower limit (DC) | 20.4V | 20.4V | 20.4V | 20.4V | 20.4V | permissible range, upper limit (DC) | 28.8V | 28.8V | 28.8V | 28.8V | 28.8V | Reverse polarity protection | Yes | Yes | Yes | Yes | Yes | Load voltage 2L+ | | | | | | | 24V | 24V | 24V | 24V | 24V | | Yes | Yes | Yes | Yes | Yes | Input current | | | | | | Current consumption, typ. | 100mA | 100mA | 100mA | 100mA | 100mA | from supply voltage 1L+, max. | 4A | 4A | 4A | 4A | 4A | from load voltage 2L+, max. | 4A | 4A | 4A | 4A | 4A | Power loss | | | | | | Power loss, typ. | 3W | 5.5W | 5.5W | 5W | 5.5W | Digital outputs | | | | | | Number of digital outputs | 8 | 8 | 8 | 8 | 16 | | 8 | 4 | 4 | 4 | 8 | Short-circuit protection | Yes | Yes | Yes | Yes | Yes | | 0.7A | 1.8A | 1.8A | 2.8A | 1.8A | Limitation of inductive shutdown voltage to | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Typ. (L1+, L2+) -47 V | Controlling a digital input | Yes | Yes | Yes | Yes | Yes | Switching capacity of the outputs | | | | | | | 5W | 5W | 5W | 10W | 5W | Output current | | | | | | | 0.5A | 1.3A; Maximum | 1.3A; Maximum | 2A | 1.3A; Maximum | | 1.5mA | 1.5mA | 1.5mA | 1.5mA | 1.5mA | Parallel switching of two outputs | | | | | | | No | No | No | No | No | | Yes | Yes | Yes | Yes | Yes | Switching frequency | | | | | | | 100Hz | 100Hz | 100Hz | 100Hz | 100Hz | | 0.5Hz | 0.5Hz | 0.5Hz | 0.5Hz | 0.5Hz | | 1Hz | 1Hz | 1Hz | 1Hz | 1Hz | Total current of the outputs (per group) | | | | | | all mounting positions | | | | | | | | 3.9A | | | | | 4A | 2.6A | 3.9A | 3.9A | 3.9A | Cable length | | | | | | | 30m | 30m | 30m | 30m | 30m | Interfaces | | | | | | Transmission procedure | 100BASE-TX | 100BASE-TX | 100BASE-TX | 100BASE-TX | 100BASE-TX | Number of PROFINET interfaces | 1 | 1 | 1 | 1 | 1 | PROFINET IO | | | | | | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | | 100Mbit/s | 100Mbit/s | 100Mbit/s | 100Mbit/s | 100Mbit/s | | Yes | Yes | Yes | Yes | Yes | Protocols | | | | | | Supports protocol for PROFINET IO | Yes | Yes | Yes | Yes | Yes | PROFINET CBA | No | No | No | No | No | PROFIsafe | No | No | No | No | No | Protocols (Ethernet) | | | | | | | No | No | No | No | No | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | PROFINET IO Device | | | | | | Services | | | | | | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | Interrupts/diagnostics/status information | | | | | | Status indicator | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | Diagnostic functions | Yes | Yes | Yes | Yes | Yes | Alarms | | | | | | | Yes | Yes | Yes | Yes | Yes | Diagnostic messages | | | | | | | Yes | Yes | Yes | Yes | Yes | | Yes; Green "ON" LED | Yes; Green "ON" LED | Yes; Green "ON" LED | Yes; Green "ON" LED | Yes; Green "ON" LED | | Yes | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Yes | | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Potential separation | | | | | | between the load voltages | Yes | Yes | Yes | Yes | Yes | between load voltage and all other switching components | No | No | No | No | No | between Ethernet and electronics | Yes | Yes | Yes | Yes | Yes | Potential separation digital outputs | | | | | | | No | No | No | No | No | Isolation | | | | | | tested with | | | | | | | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | Degree and class of protection | | | | | | IP degree of protection | IP67 | IP65/67 | IP67 | IP67 | IP67 | Standards, approvals, certificates | | | | | | Suitable for safety-oriented group deactivation | Yes | Yes | Yes | Yes | Yes | Highest safety class achievable in safety mode | | | | | | | d | d | d | d | d | | 2 | 2 | 2 | 2 | 2 | Connection method | | | | | | Design of electrical connection | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | Dimensions | | | | | | Width | 30mm | 30mm | 60mm | 60mm | 60mm | Height | 200mm | 200mm | 175mm | 175mm | 175mm | Depth | 49mm | 49mm | 49mm | 49mm | 49mm | Weights | | | | | | Weight (without packaging) | 550g | 550g | 910g | 910g | 910g |
Article number | 6ES7147-6BG00-0AB0 |
|---|
| ET200ECO PN, 8 DIO, DC24V/1,3A, 8XM12 |
|---|
General information | | Vendor identification (VendorID) | 002AH | Device identifier (DeviceID) | 0306H | Supply voltage | | Rated value (DC) | 24V | permissible range, lower limit (DC) | 20.4V | permissible range, upper limit (DC) | 28.8V | Reverse polarity protection | Yes | Load voltage 2L+ | | | 24V | | Yes | Input current | | Current consumption, typ. | 100mA | from supply voltage 1L+, max. | 4A | from load voltage 2L+, max. | 4A | Encoder supply | | Number of outputs | 8 | Short-circuit protection | Yes; Electronic | Output current | | | 100mA; per output | Power loss | | Power loss, typ. | 6.5W | Digital inputs | | Number of digital inputs | 8 | | 4 | Input characteristic curve in accordance with IEC 61131, type 3 | Yes | Number of simultaneously controllable inputs | | all mounting positions | | | 8 | Input voltage | | | DC | | 24V | | -3 to +5V | | +11 to +30V | Input current | | | 7mA | Input delay (for rated value of input voltage) | | for standard inputs | | | typically 3 ms | | typically 3 ms | Cable length | | | 30m | Digital outputs | | Number of digital outputs | 8 | | 4 | Short-circuit protection | Yes; Electronic | | 1.8A | Limitation of inductive shutdown voltage to | Typ. (L1+, L2+) -47 V | Controlling a digital input | Yes | Switching capacity of the outputs | | | 5W | Output current | | | 1.3A; Maximum | | 1.5mA | Parallel switching of two outputs | | | No | | Yes | Switching frequency | | | 100Hz | | 0.5Hz | | 1Hz | Total current of the outputs (per group) | | all mounting positions | | | 3.9A | Cable length | | | 30m | Encoder | | Connectable encoders | | | Yes | | 1.5mA | Interfaces | | Transmission procedure | 100BASE-TX | Number of PROFINET interfaces | 1 | PROFINET IO | | | Yes | | Yes | | 100Mbit/s | | Yes | Protocols | | Supports protocol for PROFINET IO | Yes | PROFINET CBA | No | PROFIsafe | No | Protocols (Ethernet) | | | No | | Yes | | Yes | | Yes | | Yes | | Yes | PROFINET IO Device | | Services | | | Yes | | Yes | Interrupts/diagnostics/status information | | Status indicator | Yes; Green LED | Diagnostic functions | Yes | Alarms | | | Yes | Diagnostic messages | | | Yes | | Yes; Green "ON" LED | | Yes | | Yes | | Yes | | Yes | | Yes; Red/yellow "SF/MT" LED | Potential separation | | between the load voltages | Yes | between load voltage and all other switching components | No | between Ethernet and electronics | Yes | Potential separation digital inputs | | | No | Potential separation digital outputs | | | No | Isolation | | tested with | | | 707 V DC (type test) | | 1500V; According to IEEE 802.3 | Degree and class of protection | | IP degree of protection | IP65/67 | Standards, approvals, certificates | | Suitable for safety-oriented group deactivation | Yes | Highest safety class achievable in safety mode | | | d | | 2 | Connection method | | Design of electrical connection | 4/5-pin M12 circular connectors | Dimensions | | Width | 60mm | Height | 175mm | Depth | 49mm | Weights | | Weight (without packaging) | 910g |
Article number | 6ES7144-6KD00-0AB0 | 6ES7144-6KD50-0AB0 |
|---|
| ET200ECO PN, 8AI; 4 U/I; 4 RTD/TC 8XM12 | ET200ECO PN, 8AI RTD/TC 8XM12 |
|---|
General information | | | Vendor identification (VendorID) | 002AH | 002AH | Device identifier (DeviceID) | 0306H | 0306H | Supply voltage | | | Rated value (DC) | 24V | 24V | permissible range, lower limit (DC) | 20.4V | 20.4V | permissible range, upper limit (DC) | 28.8V | 28.8V | Reverse polarity protection | Yes | Yes; against destruction | Input current | | | Current consumption, typ. | 110mA | 110mA | Encoder supply | | | Number of outputs | 4 | | Short-circuit protection | Yes; Electronic at 1.4 A | | Output current | | | | 1A; Maximum | | Power loss | | | Power loss, typ. | 2.8W | 2.8W | Analog inputs | | | Number of analog inputs | 8 | 8 | | 4 | | | 4 | 8 | permissible input voltage for voltage input (destruction limit), max. | 28.8 V permanent, 35 V for max. 500 ms | | Input ranges (rated values), voltages | | | | Yes | | | Yes | | | Yes | | | Yes | Yes | Input ranges (rated values), currents | | | | Yes | | | Yes | | | Yes | | Input ranges (rated values), thermocouples | | | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | Input ranges (rated values), resistance thermometer | | | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | Input ranges (rated values), resistors | | | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | Thermocouple (TC) | | | Temperature compensation | | | | Yes | Yes | | Yes | Yes | | Yes | Yes | | | Yes | | | Yes | | | Yes | Cable length | | | | 30m | 30m | Analog value generation for the inputs | | | Analog value display | SIMATIC S7 format | SIMATIC S7 format | Measurement principle | integrating | integrating | Integration and conversion time/resolution per channel | | | | 15 bit + sign | 15 bit + sign | | Yes | Yes | | 2/16.67/20/100 ms | 2/16.67/20/100 ms | | 500 / 60 / 50 / 10 Hz | 500 / 60 / 50 / 10 Hz | | 4 / 19 / 22 / 102 ms | 4 / 19 / 22 / 102 ms | Smoothing of measured values | | | | Yes | Yes | | Yes; 1 x cycle time | Yes; 1 x cycle time | | Yes; 4 x cycle time | Yes; 4 x cycle time | | Yes; 16 x cycle time | Yes; 16 x cycle time | | Yes; 64 x cycle time | Yes; 64 x cycle time | Encoder | | | Number of connectable encoders, max. | 8 | 8 | Connection of signal encoders | | | | Yes | | | Yes | | | Yes | | | Yes | Yes | | Yes | Yes | | Yes | Yes | Errors/accuracies | | | Linearity error (relative to input range), (+/-) | 0.01% | 0.01% | Temperature error (relative to input range), (+/-) | U: 0.0035%/C; I:0.006%/C; RTD: 0.0005%/C; TC: 0.0035%/C | RTD: 0.0005%/C; TC: 0.0035%/C | Crosstalk between the inputs, min. | 85dB | -85dB | Repeat accuracy in steady state at 25 C (relative to input range), (+/-) | 0.008% | 0.008% | Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | | | | 46dB | 46dB | | 70dB | 70dB | Interfaces | | | Transmission procedure | 100BASE-TX | 100BASE-TX | Number of PROFINET interfaces | 1 | 1 | PROFINET IO | | | | Yes | Yes | | Yes | Yes | | 100Mbit/s | 100Mbit/s | | Yes | Yes | Protocols | | | Supports protocol for PROFINET IO | Yes | Yes | PROFINET CBA | No | No | PROFIsafe | No | No | Protocols (Ethernet) | | | | No | No | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | PROFINET IO Device | | | Services | | | | Yes | | | Yes | Yes | Interrupts/diagnostics/status information | | | Status indicator | Yes | | Diagnostic functions | Yes | Yes | Alarms | | | | Yes | Yes | Diagnostic messages | | | | Yes | Yes | | Yes; Green "ON" LED | Yes; Green "ON" LED | | Yes; per module | | | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | | Yes | Yes | Potential separation | | | between the load voltages | Yes | Yes | between load voltage and all other switching components | No | No | between Ethernet and electronics | Yes | Yes | Potential separation analog inputs | | | | No | No | Permissible potential difference | | | Between the inputs and MANA (UCM) | 10 Vpp AC | 10 Vpp AC | Isolation | | | tested with | | | | 707 V DC (type test) | 707 V DC (type test) | | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | Degree and class of protection | | | IP degree of protection | IP65/67 | IP65/67 | Connection method | | | Design of electrical connection | 4/5-pin M12 circular connectors | 4/5-pin M12 circular connectors | Dimensions | | | Width | 60mm | 60mm | Height | 175mm | 175mm | Depth | 49mm | 49mm | Weights | | | Weight (without packaging) | 930g | 930g |
Article number | 6ES7145-6HD00-0AB0 |
|---|
| ET200ECO PN, 4AO U/I 4XM12 |
|---|
General information | | Vendor identification (VendorID) | 002AH | Device identifier (DeviceID) | 0306H | Supply voltage | | Rated value (DC) | 24V | permissible range, lower limit (DC) | 20.4V | permissible range, upper limit (DC) | 28.8V | Reverse polarity protection | Yes | Input current | | Current consumption, typ. | 280mA | Actuator supply | | Number of outputs | 4 | Short-circuit protection | Yes; Electronic at 1.4 A | Output current | | | 1A; Maximum | Power loss | | Power loss, typ. | 5.5W | Analog outputs | | Number of analog outputs | 4 | Voltage output, short-circuit protection | Yes | Voltage output, short-circuit current, max. | 30mA | Current output, no-load voltage, max. | 20V | Output ranges, voltage | | | Yes | | Yes | | Yes | Output ranges, current | | | Yes | | Yes | | Yes | Connection of actuators | | | Yes | | Yes | Load impedance (in rated range of output) | | | 1kΩ | | 1F | | 600Ω | | 1mH | Destruction limits against externally applied voltages and currents | | | 28.8 V permanent, 35 V for max. 500 ms | Cable length | | | 30m | Analog value generation for the outputs | | Analog value display | SIMATIC S7 format | Conversion principle | Resistor network | Integration and conversion time/resolution per channel | | | 15 bit + sign | | 1ms | Settling time | | | 2ms | | 1.8ms | | 2ms | Errors/accuracies | | Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | U: 0.6 mVrms; I: 0.4 nArms | Linearity error (relative to output range), (+/-) | 0.02% | Temperature error (relative to output range), (+/-) | U: 0.001%/C; I: 0.0025%/C | Crosstalk between the outputs, min. | 70dB | Repeat accuracy in steady state at 25 C (relative to output range), (+/-) | 0.008% | Interfaces | | Transmission procedure | 100BASE-TX | Number of PROFINET interfaces | 1 | PROFINET IO | | | Yes | | Yes | | 100Mbit/s | | Yes | Protocols | | Supports protocol for PROFINET IO | Yes | PROFINET CBA | No | PROFIsafe | No | Protocols (Ethernet) | | | No | | Yes | | Yes | | Yes | | Yes | | Yes | PROFINET IO Device | | Services | | | Yes | | Yes | Interrupts/diagnostics/status information | | Status indicator | Yes | Diagnostic functions | Yes | Substitute values connectable | Yes | Alarms | | | Yes | Diagnostic messages | | | Yes | | Yes; Green "ON" LED | | Yes; Channel-by-channel with current output | | Yes; Channel-by-channel with voltage output | | Yes; Red/yellow "SF/MT" LED | Potential separation | | between the load voltages | Yes | between load voltage and all other switching components | No | between Ethernet and electronics | Yes | Potential separation analog outputs | | | No | Permissible potential difference | | between M internally and the outputs | 10 Vpp AC | Isolation | | tested with | | | 707 V DC (type test) | | 1500V; According to IEEE 802.3 | Degree and class of protection | | IP degree of protection | IP65/67 | Connection method | | Design of electrical connection | 4/5-pin M12 circular connectors | Dimensions | | Width | 60mm | Height | 175mm | Depth | 49mm | Weights | | Weight (without packaging) | 930g |
Article number | 6ES7148-6JA00-0AB0 | 6ES7148-6JD00-0AB0 |
|---|
| ET 200ECO PN: IO-LINK MASTER | ET 200eco PN: IO-Link Master |
|---|
General information | | | Vendor identification (VendorID) | 002AH | 002AH | Device identifier (DeviceID) | 0306H | 0306H | Supply voltage | | | Rated value (DC) | 24V | 24V | permissible range, lower limit (DC) | 20.4V | 20.4V | permissible range, upper limit (DC) | 28.8V | 28.8V | Reverse polarity protection | Yes | Yes | Load voltage 2L+ | | | | 24V | 24V | | Yes | Yes; against destruction; load increasing | Input current | | | Current consumption, typ. | 200mA | 100mA | from supply voltage 1L+, max. | 4A | 4A | from load voltage 2L+, max. | 4A | 4A | Encoder supply | | | Number of outputs | 6 | 4 | Short-circuit protection | Yes | Yes; per channel, electronic | Output current | | | | 200mA; 100 mA per output to X5-X6 | 500mA; Per channel | Power loss | | | Power loss, typ. | 8W | 4.8W | Digital inputs | | | Number of digital inputs | 8 | | Input characteristic curve in accordance with IEC 61131, type 3 | Yes | | Number of simultaneously controllable inputs | | | all mounting positions | | | | 8 | | Input voltage | | | | 24V | | | -3 to +5V | | | +11 to +30V | | Input current | | | | 1.5mA | | | 7mA | | Input delay (for rated value of input voltage) | | | for standard inputs | | | | typically 3 ms | | | typically 3 ms | | Cable length | | | | 30m | | Digital outputs | | | Number of digital outputs | 4 | | Short-circuit protection | Yes; Electronic | | | 1.8A | | Limitation of inductive shutdown voltage to | Typ. (L1+, L2+) -47 V | | Controlling a digital input | Yes | | Switching capacity of the outputs | | | | 5W | | Output current | | | | 1.3A; Maximum | | | 1.5mA | | Parallel switching of two outputs | | | | No | | | Yes | | Switching frequency | | | | 100Hz | | | 0.5Hz | | | 1Hz | | Total current of the outputs (per group) | | | all mounting positions | | | | 3.9A | | Cable length | | | | 30m | | IO-Link | | | Number of ports | 4 | 4 | | 4 | 4 | IO-Link protocol 1.0 | Yes | Yes | IO-Link protocol 1.1 | | Yes | Transmission rate | 4.8 kBd (COM1); 38.4 kBd (COM2) | 4.8 kBaud (COM1); 38.4 kBaud (COM2), 230 kBaud (COM3) | Size of process data, input per port | 32byte | 32byte | Size of process data, input per module | 32byte | 128 bytes + 4 bytes PQI | Size of process data, output per port | 32byte | 32byte | Size of process data, output per module | 32byte | 128byte | Memory size for device parameter | | 2kbyte; for each port | Master backup | | Possible with function block IO_LINK_MASTER | Configuration without S7-PCT | | Possible; autostart function | Cable length unshielded, max. | 20m | 20m | Operating modes | | | | Yes | Yes | | Yes | Yes | | Yes | Yes; max. 100 mA | Connection of IO-Link devices | | | | Yes | Yes; via 3-core cable | | | Yes; Additional device supply: max. 2 A per port, max. 4 A per module | | Yes | | Interfaces | | | Transmission procedure | 100BASE-TX | 100BASE-TX | Number of PROFINET interfaces | 1 | 1 | PROFINET IO | | | | Yes | Yes | | Yes | Yes | | 100Mbit/s | 100Mbit/s | | Yes | Yes | Protocols | | | Supports protocol for PROFINET IO | Yes | Yes | PROFINET CBA | No | No | PROFIsafe | No | No | Protocols (Ethernet) | | | | No | No | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | | Yes | Yes | PROFINET IO Device | | | Services | | | | Yes | Yes | Interrupts/diagnostics/status information | | | Status indicator | Yes; Green LED | Yes; Green LED | Diagnostic functions | Yes | Yes | Alarms | | | | Yes | Yes | Diagnostic messages | | | | Yes | Yes | | Yes; Green "ON" LED | Yes; Green "ON" LED | | Yes | | | Yes | | | Yes | Yes; Device supply to M | | Yes | | | Yes; Red/yellow "SF/MT" LED | Yes; Red/yellow "SF/MT" LED | Potential separation | | | between the load voltages | Yes | Yes | between load voltage and all other switching components | No | No | between Ethernet and electronics | Yes | Yes | Potential separation digital inputs | | | | No | | Potential separation digital outputs | | | | No | | Isolation | | | tested with | | | | 707 V DC (type test) | 707 V DC (type test) | | 1500V; According to IEEE 802.3 | 1500V; According to IEEE 802.3 | Degree and class of protection | | | IP degree of protection | IP65/67 | IP65/67 | Standards, approvals, certificates | | | Suitable for safety-oriented group deactivation | | No | Connection method | | | Design of electrical connection | | 3/5-pin M12 round connectors | Dimensions | | | Width | 60mm | 30mm | Height | 175mm | 200mm | Depth | 49mm | 49mm | Weights | | | Weight (without packaging) | 910g | 550g |
|
|