Possible applications | Vehicle scales, overhead rail scales, hopper scales |
Model | Compression load cell |
Rated load/maximum load Emax. | - 0.5 t (0.49 tn. L.)
- 1 t (0.98 tn. L.)
- 2 t (1.97 tn. L.)
- 5 t (4.42 tn. L.)
- 10 t (9.84 tn. l.)
- 20 t (19.68 tn. L.)
- 30 t (29.53 tn. L.)
- 50 t (49.21 tn. L.)
|
Accuracy class according to OIML R60 | C31) |
Max. load cell verification intervals nlc | 3 000 |
Min. load cell verification intervals Vmin | Emax/10 000 |
Minimum application range Rmin(lc) | 30% |
Combined error Fcomb | ± 0.02% Cn |
Repeatability Fv | Not applicable |
Creep error Fcr | |
| ± 0.023% Cn |
Temperature effect | |
| 0.023% Cn/5 K |
| 0.017% Cn/5 K |
Min. dead load Emin | 0 kg |
Safe load limit Lu | 150% Emax |
Ultimate load Ld | 150% Emax |
Safe side load LIq | 75% Emax |
Rated measuring path hn at Emax | 0.5 mm |
Recommended supply voltage (range) | 5 … 12 V DC |
Rated characteristic value Cn | 2.0 ± 0.02 mV/V |
Tolerance DO of zero signal | ≤ ± 1.0% Cn |
Input resistance Re | 700 О© ± 7 О© |
Output resistance Ra | 700 О© ± 7 О© |
Insulation resistance Ris | 5 000 MО© at 50 V DC |
Rated temperature range Btn | -10 … +40 °C (-14 ... 104 °F) |
Operating temperature range Btu | -35 … +65 °C (-31 ... 149 °F) |
Storage temperature range Bts | -35 … +65 °C (-31 ... 149 °F) |
Sensor material | Stainless steel |
Degree of protection according to EN 60529; IEC 60529 | IP68 |
Cable connection | |
Function | Color |
| red |
| black |
- SIG + (measured signal +)
| green |
- SIG – (measured signal -)
| white |
| transparent |