Measuring range limits | See “Dimensional Drawings” |
Media pressure | 1 ... 100 bar (14.5 … 1450 psi) (Higher pressures on request) |
Output | |
Current output | |
| 4 … 20 mA |
| 20.8 mA ± 1 % (105 % ± 1 %) |
| |
| 100 О© |
| Rmax = (UPower Supply – 14 V)/22 mA |
| NAMUR NE 43 |
| 22 mA (112.5 %) |
| 4 mA |
Digital output | |
| HART |
| FSK |
| Transmitter |
Pulse output | |
Passive pulse output, setting pulse value (meter factor) for totalized flow or heat quantity (energy) with option Y47 (e.g.: 1 pulse/kg or 1 pulse/kWh) | |
| Max. 0.5 Hz |
| Min. 24 V DC as NAMUR or |
| open < 1 mA, max. 36 V, closed 100 mA, U < 2 V |
| open < 1 mA, max. 30 V, closed 100 mA, U < 2 V |
Accuracy | |
Standard version | |
| ± 0.75 % |
| |
| ± 1 % |
| |
- For steam, gases and liquids
| ± 2 % |
| |
Pressure and temperature compensated version | |
| |
| ± 2 % |
| ± 0.75 % |
| |
| ± 2.5 % |
| ± 1.5 % |
Repeatability | ± 0.1 % |
Installation conditions | |
(At different conditions, e.g. installation after control valve, bends or reductions, please refer to the operating instructions.) | |
| ≥ 20 x DN |
| ≥ 5 x DN |
Software | |
Uncompensated for liquids and gases, density-compensated by temperature for saturated steam | Order option 1 |
Density-compensated by temperature and pressure for superheated steam | Order option 4 |
Gross heat meter | |
When the thermal energy of steam is to be measured | Order option 5 |
Following information is required at option Y51 to Y56 | - Y51 Variable current output: Flow rate, power
- Y52 Power unit
Select one of the following units: kJ/h, MJ/h, GJ/h, Btu/h, kcal/h, kW, MW or special (custom) - Y53 Fullscale value power
- Y54 Variable pulse output: Totalized flow, energy
- Y55 Totalizer on/off
- Y56 Energy unit
Select one of the following units: kJ, MJ, GJ, Btu th, kcal, kWh, MWh or special (custom).
|
Density compensated by temperature and pressure for gases, wet gases | Order option 7 |
Wet gases | Select Y49 and enter relative humidity of process medium in % |
FAD - Free Air Delivery | |
When the delivered air of a compressor is to be measured | Order option 8 |
In Y81 to Y87 add information regarding: | - Y81 Inlet suction temperature
- Y82 Atmospheric pressure
- Y83 Pressure drop at inlet suction filter
- Y84 Inlet relative humidity
- Y85 Actual compressor rotation (rpm)
- Y86 Rated compressor rotation (rpm)Rated compressor rotation (rpm)
- Y87 Relative humidity at compressor output
|
Mixed gases | When fluid is a gas mixture, specifiy the single gas components and their amount/concentration in %. |
Rated operation conditions | |
Ambient temperature | |
| -40 … +85 °C (-40 … +185 °F) |
| -40 … +65 °C (-40 … +149 °F) |
Storage temperature | -50 … +85 °C (-58 … +185 °F) |
Media temperature | -40 … +240 °C (-40 … +464 °F) |
Density | Taken into consideration when dimensioning |
Viscosity | < 10 cP |
Reynold's number | 10 000 … 2 300 000 |
Media pressure limit | Max. 100 bar (1450 psi) Higher pressure on request (contact your local Siemens representative) |
Design | |
Material | |
| AISI 316L (1.4404)/AISI 316L (1.4435) |
| Hastelloy C22/2.4602 available on request (contact your local Siemens representative) |
| Aluminum |
- Sensor gaskets (Pick-up/Pressure sensor)
| AISI 316L(1.4435) /FPM or FFKM |
| FPM (Viton) for steam and non-aggressive gases |
| FFKM (Kalrez) for chlorine and other aggressive gases. (The meter is fitted with FPM/FFKM gasket only when configured with pressure sensor.) |
Process connections | Flange norm DIN EN 1092-1 form B1/B2 or ANSI B16.5 RF. |
| Other flanges on request (contact your local Siemens representative) |
| DN 15 … 300 (Ѕ … 12") |
| DN 15 … 100 (Ѕ … 4") |
Degree of protection | IP66/IP67 |
Dimensions and weights | See “Dimensional Drawings” |
Display and operating interface | |
Local display | 2 lines, 10 characters per line |
Languages | German, English, French |
Power supply | |
| 14 … 36 V DC |
| 14 … 30 V DC |
Certificates and approvals | |
Explosion protection | |
| II 2G EEx d ia [ia] IIC T6 |
| Class I, II, III, Div 1 & 2 |
Calibration | All flowmeters will be delivered with a 3 point calibration certificate |
Material Certificate | Certificate of compliance, pressure test, material certificate, material in acc. of NACE and PMI of pressure bearing metal parts. |
Cleaning | Choose Cleaning Class1 when fluid is oxygen or contains chloride. |
Certificates | X-ray and dye penetration test on pressure bearing weldings |