Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:
Information and display functions
Integrated communication functions
CommunicationThe safety related and standard communication between the central controller and the distributed stations takes place over PROFIBUS DP and/or PROFINET. The specially developed PROFIsafe profile supports the transfer of user data for the safety functions within the standard data message frame. Additional hardware components, e.g. special safety buses are not required. The necessary software is either integrated in the hardware components as an expansion of the operating system or loaded into the CPU later as a certified software block. Mode of operationThe safety functions of the F-CPU are included in the F program of the CPU and in the fail-safe signal modules. The signal modules monitor the output and input signals by means of discrepancy analysis and the injection of test signals. The CPU checks the proper operation of the controller by means of periodic self-tests, command tests and logic-based and time-based program execution checks. Furthermore, the I/O is checked using requests for signs of life. If an error is diagnosed in the system, the system will be placed in a safe state. An F runtime license is not required to operate the CPU 319F-3 PN/DP. ProgrammingThe CPU 319F-3 PN/DP is programmed in the same manner as the other SIMATIC S7 systems. The user program for non-fail-safe plant sections is created using familiar programming tools, e.g. STEP 7. Option packages SIMATIC S7 Distributed Safety (Classic) and SIMATIC Safety Advanced V12 (TIA Portal V12) The STEP 7 option packages "SIMATIC S7 Distributed Safety" (Classic) or SIMATIC Safety Advanced V12 (TIA Portal V12) are required for programming the safety-related program sections. The packages contain all the functions and blocks required to create an F program. The F program with the safety functions is connected in F FBD or F LAD or using special functions from the F library. Use of F FBD or F LAD simplifies configuration and programming of the plant and also acceptance testing thanks to the non-plant-specific uniform presentation form. The programmer can concentrate on configuration of the safety-related application without the need to use additional tools. |
| Каталог 2018 | Каталог 2017 | Каталог 2016 | Каталог 2015 | Каталог 2014 | Каталог 2013 | Каталог 2012 | Сертификат | Контакты | Карта сайта | Поиск |