Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6AG1417-4XT07-7AB0

SIPLUS S7-400 CPU 417-4 V7

General information

Product type designation

CPU 417-4

HW functional status

01

Firmware version

V7.0

Engineering with

  • Programming package

STEP 7 V5.4 or higher with HSP 261

CiR Configuration in RUN

CiR synchronization time, basic load

60ms

CiR synchronization time, time per I/O byte

7s

Supply voltage

Rated value (DC)

  • 24 V DC

No; Power supply via system power supply

Input current

from backplane bus 5 V DC, typ.

1.3A

from backplane bus 5 V DC, max.

1.6A

from backplane bus 24 V DC, max.

600mA; 150 mA per DP interface

from interface 5 V DC, max.

90mA; At each DP interface

Power loss

Power loss, typ.

6.5W

Power loss, max.

8W

Memory

Type of memory

RAM

Work memory

  • integrated

32Mbyte

  • integrated (for program)

16Mbyte

  • integrated (for data)

16Mbyte

  • expandable

No

Load memory

  • expandable FEPROM

Yes; with Memory Card (FLASH)

  • expandable FEPROM, max.

64Mbyte

  • integrated RAM, max.

1Mbyte

  • expandable RAM

Yes; with Memory Card (RAM)

  • expandable RAM, max.

64Mbyte

Backup

  • present

Yes

  • with battery

Yes; all data

  • without battery

No

Battery

Backup battery

  • Backup current, typ.

225A; up to 40 C

  • Backup current, max.

1275A

  • Backup time, max.

See reference manual, module data, Chapter 3.3

  • Feeding of external backup voltage to CPU

5 V DC to 15 V DC

CPU processing times

for bit operations, typ.

7.5ns

for word operations, typ.

7.5ns

for fixed point arithmetic, typ.

7.5ns

for floating point arithmetic, typ.

15ns

CPU-blocks

DB

  • Number, max.

16000; Number range: 1 to 16000

  • Size, max.

64kbyte

FB

  • Number, max.

8000; Number range: 0 to 7999

  • Size, max.

64kbyte

FC

  • Number, max.

8000; Number range: 0 to 7999

  • Size, max.

64kbyte

OB

  • Number, max.

see instruction list

  • Size, max.

64kbyte

  • Number of free cycle OBs

1; OB 1

  • Number of time alarm OBs

8; OB 10-17

  • Number of delay alarm OBs

4; OB 20-23

  • Number of cyclic interrupt OBs

9; OB 30-38 (shortest cycle that can be set = 500 s)

  • Number of process alarm OBs

8; OB 40-47

  • Number of DPV1 alarm OBs

3; OB 55-57

  • Number of isochronous mode OBs

4; OB 61-64

  • Number of multicomputing OBs

1; OB 60

  • Number of background OBs

1; OB 90

  • Number of startup OBs

3; OB 100-102

  • Number of asynchronous error OBs

9; OB 80-88

  • Number of synchronous error OBs

2; OB 121, 122

Nesting depth

  • per priority class

24

  • additional within an error OB

2

Counters, timers and their retentivity

S7 counter

  • Number

2048

Retentivity

  • adjustable

Yes

  • lower limit

0

  • upper limit

2047

  • preset

Z 0 to Z 7

Counting range

  • lower limit

0

  • upper limit

999

IEC counter

  • Number

Unlimited (limited only by RAM capacity)

S7 times

  • Number

2048

Retentivity

  • adjustable

Yes

  • lower limit

0

  • upper limit

2047

  • preset

No times retentive

Time range

  • lower limit

10ms

  • upper limit

9990s

IEC timer

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

Total working and load memory (with backup battery)

Flag

  • Number, max.

16kbyte; Size of bit memory address area

  • Retentivity available

Yes

  • Retentivity preset

MB 0 to MB 15

  • Number of clock memories

8; in 1 memory byte

Local data

  • adjustable, max.

64kbyte

  • preset

32kbyte

Address area

I/O address area

  • Inputs

16kbyte

  • Outputs

16kbyte

of which distributed

  • MPI/DP interface, inputs

2kbyte

  • MPI/DP interface, outputs

2kbyte

  • DP interface, inputs

8kbyte

  • DP interface, outputs

8kbyte

Process image

  • Inputs, adjustable

16kbyte

  • Outputs, adjustable

16kbyte

  • Inputs, default

1024byte

  • Outputs, default

1024byte

  • consistent data, max.

244byte

  • Access to consistent data in process image

Yes

Subprocess images

  • Number of subprocess images, max.

15

Digital channels

  • Inputs

131072

  • of which central

131072

  • Outputs

131072

  • of which central

131072

Analog channels

  • Inputs

8192

  • of which central

8192

  • Outputs

8192

  • of which central

8192

Hardware configuration

Number of expansion units, max.

21

connectable OPs

119

Multicomputing

Yes; 4 CPUs max. (with UR1 or UR2)

Interface modules

  • Number of connectable IMs (total), max.

6

  • Number of connectable IM 460s, max.

6

  • Number of connectable IM 463s, max.

4; IM 463-2

Number of DP masters

  • integrated

2

  • via CP

10; CP 443-5 Extended

  • via IM 467

4

  • Mixed mode IM + CP permitted

No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode

  • via interface module

2

  • Number of pluggable S5 modules (via adapter capsule in central device), max.

6

Number of IO Controllers

  • integrated

0

  • via CP

4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode

Number of operable FMs and CPs (recommended)

  • FM

Limited by number of slots and number of connections

  • CP, PtP

CP 440: Limited by number of slots; CP 441: limited by number of connections

  • PROFIBUS and Ethernet CPs

14; Of which 10 CPs max. or IMs as DP master, 4 PROFINET controller maximum

Slots

  • required slots

2

Time of day

Clock

  • Hardware clock (real-time)

Yes

  • retentive and synchronizable

Yes

  • Resolution

1ms

  • Deviation per day (buffered), max.

1.7s; Power off

  • Deviation per day (unbuffered), max.

8.6s; For power On

Operating hours counter

  • Number

16

  • Number/Number range

0 to 15

  • Range of values

SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours

  • Granularity

1 hour

  • retentive

Yes

Clock synchronization

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes

  • to DP, slave

Yes

  • in AS, master

Yes

  • in AS, slave

Yes

  • on Ethernet via NTP

No; Via CP

  • to IF 964 DP

Yes

Time difference in system when synchronizing via

  • MPI, max.

200ms

Interfaces

Interfaces/bus type

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 2 x PROFIBUS DP (optionally pluggable)

Number of RS 485 interfaces

2; Combined MPI / PROFIBUS DP and PROFIBUS DP

Number of other interfaces

2; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

1. Interface

Interface type

Integrated

Physics

RS 485 / PROFIBUS + MPI

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150mA

Number of connection resources

MPI: 44, DP: 32

Functionality

  • MPI

Yes

  • PROFIBUS DP master

Yes

  • PROFIBUS DP slave

Yes

MPI

  • Number of connections

44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

  • Transmission rate, max.

12Mbit/s

Services

  • PG/OP communication

Yes

  • Routing

Yes

  • Global data communication

Yes

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

DP master

  • Number of connections, max.

32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

  • Transmission rate, max.

12Mbit/s

  • Number of DP slaves, max.

32

Services

  • PG/OP communication

Yes

  • Routing

Yes; S7 routing

  • Global data communication

No

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV1

Yes

Address area

  • Inputs, max.

2kbyte

  • Outputs, max.

2kbyte

User data per DP slave

  • User data per DP slave, max.

244byte

  • Inputs, max.

244byte

  • Outputs, max.

244byte

  • Slots, max.

244

  • per slot, max.

128byte

DP slave

  • Number of connections

32

  • GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • Transmission rate, max.

12Mbit/s

  • automatic baud rate search

No

  • Address area, max.

32; Virtual slots

  • User data per address area, max.

32byte

  • of which consistent, max.

32byte

Services

  • PG/OP communication

Yes; with interface active

  • S7 routing

Yes; with interface active

  • Global data communication

No

  • S7 basic communication

No

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Direct data exchange (slave-to-slave communication)

No

  • DPV1

No

Transfer memory

  • Inputs

244byte

  • Outputs

244byte

2. Interface

Interface type

Integrated

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150mA

Number of connection resources

32

Functionality

  • PROFIBUS DP master

Yes

  • PROFIBUS DP slave

Yes

DP master

  • Number of connections, max.

32

  • Transmission rate, max.

12Mbit/s

  • Number of DP slaves, max.

125

Services

  • PG/OP communication

Yes

  • Routing

Yes; S7 routing

  • Global data communication

No

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV1

Yes

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

User data per DP slave

  • User data per DP slave, max.

244byte

  • Inputs, max.

244byte

  • Outputs, max.

244byte

  • Slots, max.

244

  • per slot, max.

128byte

DP slave

  • Number of connections

32

  • GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • Transmission rate, max.

12Mbit/s

  • Address area, max.

32

  • User data per address area, max.

32byte

  • of which consistent, max.

32byte

Services

  • Routing

Yes; with interface active

Transfer memory

  • Inputs

244byte

  • Outputs

244byte

3. Interface

Interface type

Pluggable interface module (IF), technical data as for 2nd interface

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150mA

automatic detection of transmission rate

No

Number of connection resources

32

Functionality

  • MPI

No

  • PROFIBUS DP master

Yes

  • PROFIBUS DP slave

Yes

DP master

  • Number of connections, max.

32

  • Number of DP slaves, max.

125

Services

  • PG/OP communication

Yes

  • Routing

Yes; S7 routing

  • Global data communication

No

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV0

Yes

  • DPV1

Yes

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

User data per DP slave

  • User data per DP slave, max.

244byte

  • Inputs, max.

244byte

  • Outputs, max.

244byte

  • Slots, max.

244

  • per slot, max.

128byte

DP slave

  • Number of connections

32

  • GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • Transmission rate, max.

12Mbit/s

  • automatic baud rate search

No

  • Address area, max.

32

  • User data per address area, max.

32byte

  • of which consistent, max.

32byte

Services

  • PG/OP communication

Yes

  • S7 routing

Yes; with interface active

  • Global data communication

No

  • S7 basic communication

No

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Direct data exchange (slave-to-slave communication)

No

  • DPV1

No

Transfer memory

  • Inputs

244byte

  • Outputs

244byte

4. Interface

Interface type

Pluggable interface module (IF), technical data as for 2nd interface

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Open IE communication

  • ISO-on-TCP (RFC1006)

Via CP 443-1 and loadable FB

  • Data length, max.

1452 bytes via CP 443-1 Adv.

Isochronous mode

Isochronous operation (application synchronized up to terminal)

Yes; For PROFIBUS only

Equidistance

Yes

Number of DP masters with isochronous mode

4

User data per isochronous slave, max.

244byte

shortest clock pulse

1ms; 0.5 ms without use of SFC 126, 127

max. cycle

32ms

Communication functions

PG/OP communication

Yes

  • Number of connectable OPs without message processing

119

  • Number of connectable OPs with message processing

119; When using Alarm_S/SQ and Alarm_D/DQ

Data record routing

Yes

Global data communication

  • supported

Yes

  • Number of GD loops, max.

16

  • Number of GD packets, transmitter, max.

16

  • Number of GD packets, receiver, max.

32

  • Size of GD packets, max.

54byte

  • Size of GD packet (of which consistent), max.

1 variable

S7 basic communication

  • supported

Yes

  • User data per job, max.

76byte

  • User data per job (of which consistent), max.

1 variable

S7 communication

  • supported

Yes

  • as server

Yes

  • as client

Yes

  • User data per job, max.

64kbyte

  • User data per job (of which consistent), max.

462byte; 1 variable

S5 compatible communication

  • supported

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

  • User data per job, max.

8kbyte

  • User data per job (of which consistent), max.

240byte

  • Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.

64/64

Standard communication (FMS)

  • supported

Yes; Via CP and loadable FB

Web server

  • supported

No

Number of connections

  • overall

120

  • usable for PG communication

119

  • reserved for PG communication

1

  • adjustable for PG communication, max.

0

  • usable for OP communication

119

  • reserved for OP communication

1

  • adjustable for OP communication, max.

0

  • usable for S7 basic communication

118

  • reserved for S7 basic communication

0

  • adjustable for S7 basic communication, max.

0

  • usable for S7 communication

118

  • reserved for S7 communication

0

  • adjustable for S7 communication, max.

0

  • usable for routing

59

  • reserved for routing

0

  • adjustable for routing, max.

0

S7 message functions

Number of login stations for message functions, max.

119; Max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)

Symbol-related messages

Yes

SCAN procedure

Yes

Program alarms

Yes

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

1000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks

Alarm 8-blocks

Yes

  • Number of instances for alarm 8 and S7 communication blocks, max.

10000

  • preset, max.

1200

Process control messages

Yes

Number of archives that can log on simultaneously (SFB 37 AR_SEND)

64

Number of messages

  • overall, max.

1024

  • in 100 ms grid, max.

128

  • in 500 ms grid, max.

512

  • in 1000 ms grid, max.

1024

Number of additional values

  • with 100 ms grid, max.

1

  • with 500, 1000 ms grid, max.

10

Test commissioning functions

Status block

Yes; Up to 16 simultaneously

Single step

Yes

Number of breakpoints

16

Status/control

  • Status/control variable

Yes; Up to 16 variable tables

  • Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

  • Number of variables, max.

70; Status/control

Forcing

  • Forcing

Yes

  • Forcing, variables

Inputs, outputs, bit memories, peripheral inputs, peripheral outputs

  • Number of variables, max.

512

Diagnostic buffer

  • present

Yes

  • Number of entries, max.

3200

  • adjustable

Yes

  • preset

120

Service data

  • can be read out

Yes

Standards, approvals, certificates

CE mark

Yes

EAC (formerly Gost-R)

Yes

Ambient conditions

Ambient temperature during operation

  • min.

-25C; = Tmin

  • max.

70C; = Tmax

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Configuration

Configuration software

  • STEP 7

Yes

Programming

  • Command set

see instruction list

  • Nesting levels

7

  • Access to consistent data in process image

Yes

  • System functions (SFC)

see instruction list

  • System function blocks (SFB)

see instruction list

Programming language

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • CFC

Yes

  • GRAPH

Yes

  • HiGraph

Yes

Number of simultaneously active SFCs

  • DPSYC_FR

2; SFC 11; per interface

  • D_ACT_DP

8; SFC 12; per interface

  • RD_REC

8; SFC 59; per interface

  • WR_REC

8; SFC 58; per interface

  • WR_PARM

8; SFC 55; per interface

  • PARM_MOD

1; SFC 57; per interface

  • WR_DPARM

2; SFC 56; per interface

  • DPNRM_DG

8; SFC 13; per interface

  • RDSYSST

8; SFC 51

  • DP_TOPOL

1; SFC 103; per interface

Number of simultaneously active SFBs

  • RDREC

8; SFB 52; per interface, but not more than 32 across all external interfaces

  • WRREC

8; SFB 53; per interface, but not more than 32 across all external interfaces

Know-how protection

  • User program protection/password protection

Yes

  • Block encryption

Yes; With S7 block Privacy

Dimensions

Width

50mm

Height

290mm

Depth

219mm

Weights

Weight, approx.

900g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS -

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK -

  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.