Supply voltage | | |
Load voltage 2L+ | | |
| 24 V | 24 V |
| Yes | Yes |
| Yes | Yes |
Input current | | |
from load voltage 2L+, max. | 300 mA; Including valves | 370 mA; Including valves |
from backplane bus 3.3 V DC, max. | 25 mA | 25 mA |
Power loss | | |
Power loss, typ. | 2.6 W | 3.7 W |
Address area | | |
Address space per module | | |
| 2 byte | 2 byte |
Digital outputs | | |
Number of digital outputs | 16 | 16 |
Load resistance range | | |
| 500 Ω | 500 Ω |
| 2 500 Ω | 2 500 Ω |
Output current | | |
| 12 mA | 16 mA |
Switching frequency | | |
| 25 Hz | 20 Hz |
Total current of the outputs (per group) | | |
all mounting positions | | |
| 250 mA; only up to 50 °C, limited by valves | 330 mA; only up to 50 °C, limited by valves |
Interrupts/diagnostics/status information | | |
Diagnostic functions | Yes | Yes |
Alarms | | |
| Yes | Yes |
Diagnostic messages | | |
| Yes | Yes |
Diagnostics indication LED | | |
| Yes | Yes |
| Yes | Yes |
Pneumatics | | |
permissible working pressure, min. | 3 bar | 3 bar |
permissible working pressure, max. | 8 bar | 8 bar |
Rated flow rate | 400 l/min | 800 l/min |
Number of connectable valves, max. | 16 | 16 |
Parameter | | |
Remark | Diagnosis load voltage 2L+ | Diagnosis load voltage 2L+ |
Response to CPU/master STOP | No | |
Potential separation | | |
between backplane bus and all other circuit components | Yes | Yes |
Potential separation digital outputs | | |
| Yes | Yes |
Isolation | | |
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) |
Standards, approvals, certificates | | |
Suitable for safety-oriented group deactivation | Yes | Yes |
Highest safety class achievable in safety mode | | |
| d | d |
| 2 | 2 |
Dimensions | | |
Width | 90 mm | 120 mm |
Height | 130 mm | 152 mm |
Depth | 47 mm | 47 mm |