Article number

6ES7317-2FK14-0AB0

CPU317F-2 PN/DP, 1.5 MB

General information

HW functional status

01

Firmware version

V3.2

Engineering with

  • Programming package

STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4

Supply voltage

Rated value (DC)

  • 24 V DC

Yes

permissible range, lower limit (DC)

20.4V

permissible range, upper limit (DC)

28.8V

external protection for power supply lines (recommendation)

2 A min.

Mains buffering

  • Mains/voltage failure stored energy time

5ms

  • Repeat rate, min.

1s

Input current

Current consumption (rated value)

750mA

Current consumption (in no-load operation), typ.

150mA

Inrush current, typ.

4A

It

1As

Power loss

Power loss, typ.

4.65W

Memory

Work memory

  • integrated

1536kbyte

  • expandable

No

  • Size of retentive memory for retentive data blocks

256kbyte

Load memory

  • Plug-in (MMC)

Yes

  • Plug-in (MMC), max.

8Mbyte

  • Data management on MMC (after last programming), min.

10y

Backup

  • present

Yes; Guaranteed by MMC (maintenance-free)

  • without battery

Yes; Program and data

CPU processing times

for bit operations, typ.

0.025s

for word operations, typ.

0.03s

for fixed point arithmetic, typ.

0.04s

for floating point arithmetic, typ.

0.16s

CPU-blocks

Number of blocks (total)

2048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

  • Number, max.

2048; Number range: 1 to 16000

  • Size, max.

64kbyte

FB

  • Number, max.

2048; Number range: 0 to 7999

  • Size, max.

64kbyte

FC

  • Number, max.

2048; Number range: 0 to 7999

  • Size, max.

64kbyte

OB

  • Size, max.

64kbyte

  • Number of free cycle OBs

1; OB 1

  • Number of time alarm OBs

1; OB 10

  • Number of delay alarm OBs

2; OB 20, 21

  • Number of cyclic interrupt OBs

4; OB 32, 33, 34, 35

  • Number of process alarm OBs

1; OB 40

  • Number of DPV1 alarm OBs

3; OB 55, 56, 57

  • Number of isochronous mode OBs

1; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously)

  • Number of startup OBs

1; OB 100

  • Number of asynchronous error OBs

6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)

  • Number of synchronous error OBs

2; OB 121, 122

Nesting depth

  • per priority class

16

  • additional within an error OB

4

Counters, timers and their retentivity

S7 counter

  • Number

512

Retentivity

  • adjustable

Yes

  • lower limit

0

  • upper limit

511

  • preset

Z 0 to Z 7

Counting range

  • can be set

Yes

  • lower limit

0

  • upper limit

999

IEC counter

  • Number

Unlimited (limited only by RAM capacity)

S7 times

  • Number

512

Retentivity

  • adjustable

Yes

  • lower limit

0

  • upper limit

511

  • preset

No retentivity

Time range

  • lower limit

10ms

  • upper limit

9990s

IEC timer

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

All, max. 256 KB

Flag

  • Number, max.

4096byte

  • Retentivity available

Yes; From MB 0 to MB 4095

  • Retentivity preset

MB 0 to MB 15

  • Number of clock memories

8; 1 memory byte

Data blocks

  • Retentivity adjustable

Yes; via non-retain property on DB

  • Retentivity preset

Yes

Local data

  • per priority class, max.

32768byte; Max. 2048 bytes per block

Address area

I/O address area

  • Inputs

8192byte

  • Outputs

8192byte

of which distributed

  • Inputs

8192byte

  • Outputs

8192byte

Process image

  • Inputs

8192byte

  • Outputs

8192byte

  • Inputs, adjustable

8192byte

  • Outputs, adjustable

8192byte

  • Inputs, default

256byte

  • Outputs, default

256byte

Subprocess images

  • Number of subprocess images, max.

1; With PROFINET IO, the length of the user data is limited to 1600 bytes

Digital channels

  • Inputs

65536

  • of which central

1024

  • Outputs

65536

  • of which central

1024

Analog channels

  • Inputs

4096

  • of which central

256

  • Outputs

4096

  • of which central

256

Hardware configuration

Number of expansion units, max.

3

Number of DP masters

  • integrated

1

  • via CP

4

Number of operable FMs and CPs (recommended)

  • FM

8

  • CP, PtP

8

  • CP, LAN

10

Rack

  • Racks, max.

4

  • Modules per rack, max.

8

Time of day

Clock

  • Hardware clock (real-time)

Yes

  • retentive and synchronizable

Yes

  • Backup time

6wk; At 40 C ambient temperature

  • Deviation per day, max.

10s; Typ.: 2 s

  • Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

  • Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Operating hours counter

  • Number

4

  • Number/Number range

0 to 3

  • Range of values

0 to 2^31 hours (when using SFC 101)

  • Granularity

1 hour

  • retentive

Yes; Must be restarted at each restart

Clock synchronization

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes; With DP slave only slave clock

  • to DP, slave

Yes

  • in AS, master

Yes

  • in AS, slave

Yes

  • on Ethernet via NTP

Yes; As client

Digital inputs

Number of digital inputs

0

Digital outputs

Number of digital outputs

0

Analog inputs

Number of analog inputs

0

Analog outputs

Number of analog outputs

0

Interfaces

Number of industrial Ethernet interfaces

1

Number of PROFINET interfaces

1

Number of RS 485 interfaces

1

Number of RS 422 interfaces

0

1. Interface

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200mA

Functionality

  • MPI

Yes

  • PROFIBUS DP master

Yes

  • PROFIBUS DP slave

Yes

  • Point-to-point connection

No

MPI

  • Transmission rate, max.

12Mbit/s

Services

  • PG/OP communication

Yes

  • Routing

Yes

  • Global data communication

Yes

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

No; but via CP and loadable FB

  • S7 communication, as server

Yes

DP master

  • Transmission rate, max.

12Mbit/s

  • Number of DP slaves, max.

124

Services

  • PG/OP communication

Yes

  • Routing

Yes

  • Global data communication

No

  • S7 basic communication

Yes; I blocks only

  • S7 communication

Yes

  • S7 communication, as client

No

  • S7 communication, as server

Yes

  • Equidistance

Yes

  • Isochronous mode

Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Number of DP slaves that can be simultaneously activated/deactivated, max.

8

  • Direct data exchange (slave-to-slave communication)

Yes; As subscriber

  • DPV1

Yes

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

User data per DP slave

  • Inputs, max.

244byte

  • Outputs, max.

244byte

DP slave

  • Transmission rate, max.

12Mbit/s

  • automatic baud rate search

Yes; only with passive interface

  • Address area, max.

32

  • User data per address area, max.

32byte

Services

  • PG/OP communication

Yes

  • Routing

Yes; Only with active interface

  • Global data communication

No

  • S7 basic communication

No

  • S7 communication

Yes

  • S7 communication, as client

No

  • S7 communication, as server

Yes; Connection configured on one side only

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV1

No

Transfer memory

  • Inputs

244byte

  • Outputs

244byte

2. Interface

Interface type

PROFINET

Physics

Ethernet RJ45

Isolated

Yes

automatic detection of transmission rate

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes

Interface types

  • Number of ports

2

  • integrated switch

Yes

Media redundancy

  • supported

Yes

  • Switchover time on line break, typ.

200ms; PROFINET MRP

  • Number of stations in the ring, max.

50

Functionality

  • MPI

No

  • PROFINET IO Controller

Yes; Also simultaneously with IO-Device functionality

  • PROFINET IO Device

Yes; Also simultaneously with IO Controller functionality

  • PROFINET CBA

Yes

  • PROFIBUS DP master

No

  • PROFIBUS DP slave

No

  • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • Web server

Yes

PROFINET IO Controller

  • Transmission rate, max.

100Mbit/s

Services

  • PG/OP communication

Yes

  • Routing

Yes

  • S7 communication

Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32

  • Isochronous mode

Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO

  • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • IRT

Yes

  • Shared device

Yes

  • Prioritized startup

Yes

  • Number of IO devices with prioritized startup, max.

32

  • Number of connectable IO Devices, max.

128

  • Of which IO devices with IRT, max.

64

  • of which in line, max.

64

  • Number of IO Devices with IRT and the option "high flexibility"

128

  • of which in line, max.

61

  • Number of connectable IO Devices for RT, max.

128

  • of which in line, max.

128

  • Activation/deactivation of IO Devices

Yes

  • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • IO Devices changing during operation (partner ports), supported

Yes

  • Number of IO Devices per tool, max.

8

  • Device replacement without swap medium

Yes

  • Send cycles

250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)

  • Updating time

250 s to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details)

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

  • User data consistency, max.

1024byte

PROFINET IO Device

Services

  • PG/OP communication

Yes

  • Routing

Yes

  • S7 communication

Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32

  • Isochronous mode

No

  • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • IRT

Yes

  • PROFIenergy

Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device

  • Shared device

Yes

  • Number of IO Controllers with shared device, max.

2

Transfer memory

  • Inputs, max.

1440byte; Per IO Controller with shared device

  • Outputs, max.

1440byte; Per IO Controller with shared device

Submodules

  • Number, max.

64

  • User data per submodule, max.

1024byte

PROFINET CBA

  • acyclic transmission

Yes

  • cyclic transmission

Yes

Open IE communication

  • Number of connections, max.

16

  • Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • Keep-alive function, supported

Yes

Protocols

Open IE communication

  • TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

  • Data length for connection type 01H, max.

1460byte

  • Data length for connection type 11H, max.

32768byte

  • several passive connections per port, supported

Yes

  • ISO-on-TCP (RFC1006)

Yes; via integrated PROFINET interface and loadable FBs

  • Data length, max.

32768byte

  • UDP

Yes; via integrated PROFINET interface and loadable FBs

  • Data length, max.

1472byte

Web server

  • User-defined websites

Yes

  • Number of HTTP clients

5

Isochronous mode

Isochronous operation (application synchronized up to terminal)

Yes; Via PROFIBUS DP or PROFINET interface

Communication functions

PG/OP communication

Yes

Data record routing

Yes

Global data communication

  • supported

Yes

  • Number of GD loops, max.

8

  • Number of GD packets, max.

8

  • Number of GD packets, transmitter, max.

8

  • Number of GD packets, receiver, max.

8

  • Size of GD packets, max.

22byte

  • Size of GD packet (of which consistent), max.

22byte

S7 basic communication

  • supported

Yes

  • User data per job, max.

76byte

  • User data per job (of which consistent), max.

76byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

  • supported

Yes

  • as server

Yes

  • as client

Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB

  • User data per job, max.

See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)

S5 compatible communication

  • supported

Yes; via CP and loadable FC

Web server

  • supported

Yes

PROFINET CBA (at set setpoint communication load)

  • Setpoint for the CPU communication load

50%

  • Number of remote interconnection partners

32

  • Number of functions, master/slave

30

  • Total of all master/slave connections

1000

  • Data length of all incoming connections master/slave, max.

4000byte

  • Data length of all outgoing connections master/slave, max.

4000byte

  • Number of device-internal and PROFIBUS interconnections

500

  • Data length of device-internal und PROFIBUS interconnections, max.

4000byte

  • Data length per connection, max.

1400byte

Remote interconnections with acyclic transmission

  • Sampling frequency: Sampling time, min.

500ms

  • Number of incoming interconnections

100

  • Number of outgoing interconnections

100

  • Data length of all incoming interconnections, max.

2000byte

  • Data length of all outgoing interconnections, max.

2000byte

  • Data length per connection, max.

1400byte

Remote interconnections with cyclic transmission

  • Transmission frequency: Transmission interval, min.

10ms

  • Number of incoming interconnections

200

  • Number of outgoing interconnections

200

  • Data length of all incoming interconnections, max.

2000byte

  • Data length of all outgoing interconnections, max.

2000byte

  • Data length per connection, max.

450byte

HMI variables via PROFINET (acyclic)

  • Number of stations that can log on for HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

  • HMI variable updating

500ms

  • Number of HMI variables

200

  • Data length of all HMI variables, max.

2000byte

PROFIBUS proxy functionality

  • supported

Yes

  • Number of linked PROFIBUS devices

16

  • Data length per connection, max.

240byte; Slave-dependent

Number of connections

  • overall

32

  • usable for PG communication

31

  • reserved for PG communication

1

  • adjustable for PG communication, min.

1

  • adjustable for PG communication, max.

31

  • usable for OP communication

31

  • reserved for OP communication

1

  • adjustable for OP communication, min.

1

  • adjustable for OP communication, max.

31

  • usable for S7 basic communication

30

  • reserved for S7 basic communication

0

  • adjustable for S7 basic communication, min.

0

  • adjustable for S7 basic communication, max.

30

  • usable for S7 communication

16

  • reserved for S7 communication

0

  • adjustable for S7 communication, min.

0

  • adjustable for S7 communication, max.

16

  • total number of instances, max.

32

  • usable for routing

X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.

S7 message functions

Number of login stations for message functions, max.

32; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

300

Test commissioning functions

Status block

Yes; Up to 2 simultaneously

Single step

Yes

Number of breakpoints

4

Status/control

  • Status/control variable

Yes

  • Variables

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

30

  • of which status variables, max.

30

  • of which control variables, max.

14

Forcing

  • Forcing

Yes

  • Forcing, variables

Inputs, outputs

  • Number of variables, max.

10

Diagnostic buffer

  • present

Yes

  • Number of entries, max.

500

  • adjustable

No

  • of which powerfail-proof

100; Only the last 100 entries are retained

  • Number of entries readable in RUN, max.

499

  • can be set

Yes; From 10 to 499

  • preset

10

Service data

  • can be read out

Yes

Ambient conditions

Ambient temperature during operation

  • min.

0C

  • max.

60C

Configuration

Configuration software

  • STEP 7

Yes; V5.5 or higher

Programming

  • Command set

see instruction list

  • Nesting levels

8

  • System functions (SFC)

see instruction list

  • System function blocks (SFB)

see instruction list

Programming language

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • CFC

Yes

  • GRAPH

Yes

  • HiGraph

Yes

Know-how protection

  • User program protection/password protection

Yes

  • Block encryption

Yes; With S7 block Privacy

Dimensions

Width

40mm

Height

125mm

Depth

130mm

Weights

Weight, approx.

340g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS -

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK -
2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Introduction Industrial Ethernet PROFINET Introduction Drive systems Controllers Modular controllers SIMATIC S7-1200 SIMATIC S7-1500 SIMATIC S7-300 Central processing units Standard CPUs Compact CPUs Fail-safe CPUs CPU 315F-2 PN/DP SIPLUS S7-300 CPU 315F-2 PN/DP CPU 317F-2 PN/DP SIPLUS S7-300 CPU 317F-2 PN/DP CPU 319F-3 PN/DP SIMATIC S7-400 Distributed controllers PC-based controllers Embedded Controllers Embedded bundles Communication for SIMATIC S7-1500 System interfaces / SIMATIC S7 / Communication for SIMATIC S7-300 System interfaces / SIMATIC S7 / Communication for SIMATIC S7-400 System interfaces for PG/PC/IPC / Communication for PC-based systems SIMATIC PCS 7 process control systems Distributed I/O Motion control systems CNC controls Operator panels Industrial PC Switching and protection devices for power distribution Power Monitoring SENTRON measuring devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial identification systems Network components Industrial controls SITOP power supplies Software and tools Network management and diagnostics Technology components PROFIBUS AS-Interface IO-Link Industrial wireless communication Industrial remote communication Industrial security Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.