General information | | |
HW functional status | 01 | 01 |
Firmware version | V3.3 | V3.3 |
Engineering with | | |
| STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 | STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
Supply voltage | | |
Rated value (DC) | | |
| Yes; A power supply according to EN 50155 shall be used | Yes |
permissible range, lower limit (DC) | 19.2V | 19.2V |
permissible range, upper limit (DC) | 28.8V | 28.8V |
external protection for power supply lines (recommendation) | Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A | Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A |
Mains buffering | | |
| 5ms | 5ms |
| 1s | 1s |
Load voltage L+ | | |
Digital inputs | | |
| 24V | 24V |
| Yes | Yes |
Digital outputs | | |
| 24V | 24V |
| No | No |
Input current | | |
Current consumption (rated value) | 880mA | 880mA |
Current consumption (in no-load operation), typ. | 150mA | 150mA |
Inrush current, typ. | 5A | 5A |
It | 0.7As | 0.7As |
Digital inputs | | |
| 80mA | 80mA |
Digital outputs | | |
| 50mA | 50mA |
Power loss | | |
Power loss, typ. | 13W | 13W |
Memory | | |
Work memory | | |
| 192kbyte | 192kbyte |
| No | No |
| 64kbyte | 64kbyte |
Load memory | | |
| Yes | Yes |
| 8Mbyte | 8Mbyte |
| 10y | 10y |
Backup | | |
| Yes; Guaranteed by MMC (maintenance-free) | Yes; Guaranteed by MMC (maintenance-free) |
| Yes; Program and data | Yes; Program and data |
CPU processing times | | |
for bit operations, typ. | 0.06s | 0.06s |
for word operations, typ. | 0.12s | 0.12s |
for fixed point arithmetic, typ. | 0.16s | 0.16s |
for floating point arithmetic, typ. | 0.59s | 0.59s |
CPU-blocks | | |
Number of blocks (total) | 1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | 1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB | | |
| 1024; Number range: 1 to 16000 | 1024; Number range: 1 to 16000 |
| 64kbyte | 64kbyte |
FB | | |
| 1024; Number range: 0 to 7999 | 1024; Number range: 0 to 7999 |
| 64kbyte | 64kbyte |
FC | | |
| 1024; Number range: 0 to 7999 | 1024; Number range: 0 to 7999 |
| 64kbyte | 64kbyte |
OB | | |
| see instruction list | see instruction list |
| 64kbyte | 64kbyte |
| 1; OB 1 | 1; OB 1 |
| 1; OB 10 | 1; OB 10 |
| 2; OB 20, 21 | 2; OB 20, 21 |
| 4; OB 32, 33, 34, 35 | 4; OB 32, 33, 34, 35 |
| 1; OB 40 | 1; OB 40 |
| 3; OB 55, 56, 57 | 3; OB 55, 56, 57 |
| 1; OB 100 | 1; OB 100 |
| 5; OB 80, 82, 85, 86, 87 | 5; OB 80, 82, 85, 86, 87 |
| 2; OB 121, 122 | 2; OB 121, 122 |
Nesting depth | | |
| 16 | 16 |
| 4 | 4 |
Counters, timers and their retentivity | | |
S7 counter | | |
| 256 | 256 |
Retentivity | | |
| Yes | Yes |
| 0 | 0 |
| 255 | 255 |
| Z 0 to Z 7 | Z 0 to Z 7 |
Counting range | | |
| 0 | 0 |
| 999 | 999 |
IEC counter | | |
| Unlimited (limited only by RAM capacity) | Unlimited (limited only by RAM capacity) |
S7 times | | |
| 256 | 256 |
Retentivity | | |
| Yes | Yes |
| 0 | 0 |
| 255 | 255 |
| No retentivity | No retentivity |
Time range | | |
| 10ms | 10ms |
| 9990s | 9990s |
IEC timer | | |
| Yes | Yes |
| SFB | SFB |
| Unlimited (limited only by RAM capacity) | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity | | |
retentive data area in total | All, max. 64 KB | All, max. 64 KB |
Flag | | |
| 256byte | 256byte |
| Yes; MB 0 to MB 255 | Yes; MB 0 to MB 255 |
| MB 0 to MB 15 | MB 0 to MB 15 |
| 8; 1 memory byte | 8; 1 memory byte |
Data blocks | | |
| Yes; via non-retain property on DB | Yes; via non-retain property on DB |
| Yes | Yes |
Local data | | |
| 32kbyte; Max. 2048 bytes per block | 32kbyte; Max. 2048 bytes per block |
Address area | | |
I/O address area | | |
| 2048byte | 2048byte |
| 2048byte | 2048byte |
of which distributed | | |
| 2003byte | 2003byte |
| 2010byte | 2010byte |
Process image | | |
| 2048byte | 2048byte |
| 2048byte | 2048byte |
| 2048byte | 2048byte |
| 2048byte | 2048byte |
| 128byte | 128byte |
| 128byte | 128byte |
Default addresses of the integrated channels | | |
| 124.0 to 126.7 | 124.0 to 126.7 |
| 124.0 to 125.7 | 124.0 to 125.7 |
| 752 to 761 | 752 to 761 |
| 752 to 755 | 752 to 755 |
Digital channels | | |
| 16048 | 16048 |
| 1016 | 1016 |
| 16096 | 16096 |
| 1008 | 1008 |
Analog channels | | |
| 1006 | 1006 |
| 253 | 253 |
| 1007 | 1007 |
| 250 | 250 |
Hardware configuration | | |
Number of expansion units, max. | 3 | 3 |
Number of DP masters | | |
| 1 | 1 |
| 4 | 4 |
Number of operable FMs and CPs (recommended) | | |
| 8 | 8 |
| 8 | 8 |
| 10 | 10 |
Rack | | |
| 4 | 4 |
| 8; In rack 3 max. 7 | 8; In rack 3 max. 7 |
Time of day | | |
Clock | | |
| Yes | Yes |
| Yes | Yes |
| 6wk; At 40 C ambient temperature | 6wk; At 40 C ambient temperature |
| 10s; Typ.: 2 s | 10s; Typ.: 2 s |
| Clock continues running after POWER OFF | Clock continues running after POWER OFF |
| Clock continues to run with the time at which the power failure occurred | Clock continues to run with the time at which the power failure occurred |
Operating hours counter | | |
| 1 | 1 |
| 0 | 0 |
| 0 to 2^31 hours (when using SFC 101) | 0 to 2^31 hours (when using SFC 101) |
| 1 hour | 1 hour |
| Yes; Must be restarted at each restart | Yes; Must be restarted at each restart |
Clock synchronization | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes; With DP slave only slave clock | Yes; With DP slave only slave clock |
| Yes | Yes |
| Yes | Yes |
| No | No |
Digital inputs | | |
Number of digital inputs | 24 | 24 |
| 16 | 16 |
integrated channels (DI) | 24 | 24 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes | Yes |
horizontal installation | | |
| 24 | 24 |
| 12 | 12; up to 70 C |
vertical installation | | |
| 12 | 12 |
Input voltage | | |
| 24V | 24V |
| -3 to +5V | -3 to +5V |
| +15 to +30V | +15 to +30V |
Input current | | |
| 8mA | 8mA |
Input delay (for rated value of input voltage) | | |
for standard inputs | | |
| Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.) | Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.) |
| 3ms | 3ms |
for counter/technological functions | | |
| 8s; Minimum pulse width/minimum pause between pulses at maximum counting frequency | 8s; Minimum pulse width/minimum pause between pulses at maximum counting frequency |
Cable length | | |
| 1000m; 50 m for technological functions | 1000m; 50 m for technological functions |
| 600m; For technological functions: No | 600m; For technological functions: No |
for technological functions | | |
| 50m; at maximum count frequency | 50m; at maximum count frequency |
| not allowed | not allowed |
Digital outputs | | |
Number of digital outputs | 16 | 16 |
| 4; Notice: You cannot connect the fast outputs of your CPU in parallel | 4; Notice: You cannot connect the fast outputs of your CPU in parallel |
integrated channels (DO) | 16 | 16 |
Short-circuit protection | Yes; Clocked electronically | Yes; Clocked electronically |
| 1A | 1A |
Limitation of inductive shutdown voltage to | L+ (-48 V) | L+ (-48 V) |
Controlling a digital input | Yes | Yes |
Switching capacity of the outputs | | |
| 5W | 5W |
Load resistance range | | |
| 48Ω | 48Ω |
| 4kΩ | 4kΩ |
Output voltage | | |
| L+ (-0.8 V) | L+ (-0.8 V) |
Output current | | |
| 500mA | 500mA |
| 5mA | 5mA |
| 0.6A | 0.6A |
| 5mA | 5mA |
| 0.5mA | 0.5mA |
Parallel switching of two outputs | | |
| No | No |
| Yes | Yes |
Switching frequency | | |
| 100Hz | 100Hz |
| 0.5Hz | 0.5Hz |
| 100Hz | 100Hz |
| 2.5kHz | 2.5kHz |
horizontal installation | | |
| 3A | 3A |
| 2A | 2A; 1.5 A @ > 60 C |
vertical installation | | |
| 2A | 2A |
Cable length | | |
| 1000m | 1000m |
| 600m | 600m |
Analog inputs | | |
Number of analog inputs | 5 | 5 |
| 4 | 4 |
| 1 | 1 |
integrated channels (AI) | 5; 4 x current/voltage, 1 x resistance | 5; 4 x current/voltage, 1 x resistance |
permissible input voltage for current input (destruction limit), max. | 5V; Permanent | 5V; Permanent |
permissible input voltage for voltage input (destruction limit), max. | 30V; Permanent | 30V; Permanent |
permissible input current for voltage input (destruction limit), max. | 0.5mA; Permanent | 0.5mA; Permanent |
permissible input current for current input (destruction limit), max. | 50mA; Permanent | 50mA; Permanent |
No-load voltage, typ. | 3.3V | 3.3V |
Constant measurement current for resistance-type transmitter, typ. | 1.25mA | 1.25mA |
Technical unit for temperature measurement adjustable | Yes; Degrees Celsius / degrees Fahrenheit / Kelvin | Yes; Degrees Celsius / degrees Fahrenheit / Kelvin |
Input ranges | | |
| Yes; 10 V / 100 kΩ; 0 V to 10 V / 100 kΩ | Yes; 10 V / 100 kΩ; 0 V to 10 V / 100 kΩ |
| Yes; 20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω | Yes; 20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω |
| Yes; Pt 100 / 10 MΩ | Yes; Pt 100 / 10 MΩ |
| Yes; 0 Ω to 600 Ω / 10 MΩ | Yes; 0 Ω to 600 Ω / 10 MΩ |
Input ranges (rated values), voltages | | |
| Yes | Yes |
| 100kΩ | 100kΩ |
Input ranges (rated values), currents | | |
| Yes | Yes |
| 100Ω | 100Ω |
| Yes | Yes |
| 100Ω | 100Ω |
| Yes | Yes |
| 100Ω | 100Ω |
Input ranges (rated values), resistance thermometer | | |
| Yes | Yes |
| 10MΩ | 10MΩ |
Input ranges (rated values), resistors | | |
| Yes | Yes |
| 10MΩ | 10MΩ |
Thermocouple (TC) | | |
Temperature compensation | | |
| No | No |
Characteristic linearization | | |
| Yes; by software | Yes; by software |
| Pt 100 | Pt 100 |
Cable length | | |
| 100m | 100m |
Analog outputs | | |
Number of analog outputs | 2 | 2 |
integrated channels (AO) | 2 | 2 |
Voltage output, short-circuit protection | Yes | Yes |
Voltage output, short-circuit current, max. | 55mA | 55mA |
Current output, no-load voltage, max. | 14V | 14V |
Output ranges, voltage | | |
| Yes | Yes |
| Yes | Yes |
Output ranges, current | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Connection of actuators | | |
| Yes; Without compensation of the line resistances | Yes; Without compensation of the line resistances |
| No | No |
| Yes | Yes |
Load impedance (in rated range of output) | | |
| 1kΩ | 1kΩ |
| 0.1F | 0.1F |
| 300Ω | 300Ω |
| 0.1mH | 0.1mH |
Destruction limits against externally applied voltages and currents | | |
| 16V; Permanent | 16V; Permanent |
| 50mA; Permanent | 50mA; Permanent |
Cable length | | |
| 200m | 200m |
Analog value generation for the inputs | | |
Measurement principle | Actual value encryption (successive approximation) | Actual value encryption (successive approximation) |
Integration and conversion time/resolution per channel | | |
| 12bit | 12bit |
| Yes; 16.6 / 20 ms | Yes; 16.6 / 20 ms |
| 50 / 60 Hz | 50 / 60 Hz |
| 400Hz | 400Hz |
| 0.38ms | 0.38ms |
| 1ms | 1ms |
Analog value generation for the outputs | | |
Integration and conversion time/resolution per channel | | |
| 12bit | 12bit |
| 1ms | 1ms |
Settling time | | |
| 0.6ms | 0.6ms |
| 1ms | 1ms |
| 0.5ms | 0.5ms |
Encoder | | |
Connection of signal encoders | | |
| Yes | Yes |
| Yes; with external supply | Yes; with external supply |
| Yes | Yes |
| Yes; Without compensation of the line resistances | Yes; Without compensation of the line resistances |
| No | No |
| No | No |
Connectable encoders | | |
| Yes | Yes |
| 1.5mA | 1.5mA |
Errors/accuracies | | |
Temperature error (relative to input range), (+/-) | 0.006%/K | 0.006%/K |
Crosstalk between the inputs, min. | 60dB | 60dB |
Repeat accuracy in steady state at 25 C (relative to input range), (+/-) | 0.06% | 0.06% |
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | 0.1% | 0.1% |
Linearity error (relative to output range), (+/-) | 0.15% | 0.15% |
Temperature error (relative to output range), (+/-) | 0.01%/K | 0.01%/K |
Crosstalk between the outputs, min. | 60dB | 60dB |
Repeat accuracy in steady state at 25 C (relative to output range), (+/-) | 0.06% | 0.06% |
Operational error limit in overall temperature range | | |
| 1% | 1% |
| 1% | 1% |
| 1% | 1% |
| 1% | 1% |
| 1% | 1% |
Basic error limit (operational limit at 25 C) | | |
| 0.8%; Linearity error 0.06 % | 0.8%; Linearity error 0.06 % |
| 0.8%; Linearity error 0.06 % | 0.8%; Linearity error 0.06 % |
| 0.8%; Linearity error 0.2 % | 0.8%; Linearity error 0.2 % |
| 0.8% | 0.8% |
| 0.8% | 0.8% |
| 0.8% | 0.8% |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | | |
| 30dB | 30dB |
| 40dB | 40dB |
Interfaces | | |
Number of industrial Ethernet interfaces | 0 | 0 |
Number of PROFINET interfaces | 0 | 0 |
Number of RS 485 interfaces | 2; MPI and PROFIBUS DP | 2; MPI and PROFIBUS DP |
Number of RS 422 interfaces | 0 | 0 |
1. Interface | | |
Interface type | Integrated RS 485 interface | Integrated RS 485 interface |
Physics | RS 485 | RS 485 |
Isolated | No | No |
Power supply to interface (15 to 30 V DC), max. | 200mA | 200mA |
Functionality | | |
| Yes | Yes |
| No | No |
| No | No |
| No | No |
MPI | | |
| 187.5kbit/s | 187.5kbit/s |
Services | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes; Only server, configured on one side | Yes; Only server, configured on one side |
| No; but via CP and loadable FB | No; but via CP and loadable FB |
| Yes | Yes |
2. Interface | | |
Interface type | Integrated RS 485 interface | Integrated RS 485 interface |
Physics | RS 485 | RS 485 |
Isolated | Yes | Yes |
Power supply to interface (15 to 30 V DC), max. | 200mA | 200mA |
Functionality | | |
| No | No |
| No | No |
| No | No |
| No | No |
| Yes | Yes |
| Yes | Yes |
| No | No |
DP master | | |
| 12Mbit/s | 12Mbit/s |
| 124 | 124 |
Services | | |
| Yes | Yes |
| Yes | Yes |
| No | No |
| Yes; I blocks only | Yes; I blocks only |
| Yes; Only server, configured on one side | Yes; Only server, configured on one side |
| No | No |
| Yes | Yes |
| Yes | Yes |
| No | No |
| Yes | Yes |
| Yes | Yes |
| 8 | 8 |
| Yes; As subscriber | Yes; As subscriber |
| Yes | Yes |
Address area | | |
| 2kbyte | 2kbyte |
| 2kbyte | 2kbyte |
User data per DP slave | | |
| 244byte | 244byte |
| 244byte | 244byte |
DP slave | | |
| The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd) | The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd) |
| 12Mbit/s | 12Mbit/s |
| Yes; only with passive interface | Yes; only with passive interface |
| 32 | 32 |
| 32byte | 32byte |
Services | | |
| Yes | Yes |
| Yes; Only with active interface | Yes; Only with active interface |
| No | No |
| No | No |
| Yes; Only server, configured on one side | Yes; Only server, configured on one side |
| No | No |
| Yes | Yes |
| Yes | Yes |
| No | No |
Transfer memory | | |
| 244byte | 244byte |
| 244byte | 244byte |
Communication functions | | |
PG/OP communication | Yes | Yes |
Data record routing | Yes | Yes |
Global data communication | | |
| Yes | Yes |
| 8 | 8 |
| 8 | 8 |
| 8 | 8 |
| 8 | 8 |
| 22byte | 22byte |
| 22byte | 22byte |
S7 basic communication | | |
| Yes | Yes |
| 76byte | 76byte |
| 76byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | 76byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication | | |
| Yes | Yes |
| Yes | Yes |
| Yes; Via CP and loadable FB | Yes; Via CP and loadable FB |
| 180kbyte; With PUT/GET | 180kbyte; With PUT/GET |
| 240byte; as server | 240byte; as server |
S5 compatible communication | | |
| Yes; via CP and loadable FC | Yes; via CP and loadable FC |
Number of connections | | |
| 12 | 12 |
| 11 | 11 |
| 1 | 1 |
| 1 | 1 |
| 11 | 11 |
| 11 | 11 |
| 1 | 1 |
| 1 | 1 |
| 11 | 11 |
| 8 | 8 |
| 0 | 0 |
| 0 | 0 |
| 8 | 8 |
| 4; max. | 4; max. |
S7 message functions | | |
Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication | 12; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes | Yes |
simultaneously active Alarm-S blocks, max. | 300 | 300 |
Test commissioning functions | | |
Status block | Yes; Up to 2 simultaneously | Yes; Up to 2 simultaneously |
Single step | Yes | Yes |
Number of breakpoints | 4 | 4 |
Status/control | | |
| Yes | Yes |
| Inputs, outputs, memory bits, DB, times, counters | Inputs, outputs, memory bits, DB, times, counters |
| 30 | 30 |
| 30 | 30 |
| 14 | 14 |
Forcing | | |
| Yes | Yes |
| Inputs, outputs | Inputs, outputs |
| 10 | 10 |
Diagnostic buffer | | |
| Yes | Yes |
| 500 | 500 |
| No | No |
| 100; Only the last 100 entries are retained | 100; Only the last 100 entries are retained |
| 499 | 499 |
| Yes; From 10 to 499 | Yes; From 10 to 499 |
| 10 | 10 |
Service data | | |
| Yes | Yes |
Interrupts/diagnostics/status information | | |
Diagnostics indication LED | | |
| Yes | Yes |
| Yes | Yes |
Integrated Functions | | |
Number of counters | 4; See "Technological Functions" manual | 4; See "Technological Functions" manual |
Counting frequency (counter) max. | 60kHz | 60kHz |
Frequency measurement | Yes | Yes |
Number of frequency meters | 4; up to 60 kHz (see "Technological Functions" manual) | 4; up to 60 kHz (see "Technological Functions" manual) |
controlled positioning | Yes | Yes |
integrated function blocks (closed-loop control) | Yes; PID controller (see "Technological Functions" manual) | Yes; PID controller (see "Technological Functions" manual) |
PID controller | Yes | Yes |
Number of pulse outputs | 4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual) | 4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual) |
Limit frequency (pulse) | 2.5kHz | 2.5kHz |
Potential separation | | |
Potential separation digital inputs | | |
| Yes | Yes |
| No | No |
| Yes | Yes |
Potential separation digital outputs | | |
| Yes | Yes |
| Yes | Yes |
| 8 | 8 |
| Yes | Yes |
Potential separation analog inputs | | |
| Yes; common for analog I/O | Yes; common for analog I/O |
| No | No |
| Yes | Yes |
Potential separation analog outputs | | |
| Yes; common for analog I/O | Yes; common for analog I/O |
| No | No |
| Yes | Yes |
Permissible potential difference | | |
between different circuits | 75 V DC/60 V AC | 75 V DC/60 V AC |
Between the inputs and MANA (UCM) | 8 V DC | 8 V DC |
between MANA and M internally (UISO) | 75 V DC/60 V AC | 75 V DC/60 V AC |
Isolation | | |
Isolation tested with | 500V AC for 1 minute | 600 V DC |
Standards, approvals, certificates | | |
CE mark | Yes | Yes |
UL approval | Yes | Yes |
FM approval | No | No |
RCM (formerly C-TICK) | Yes | Yes |
KC approval | Yes | Yes |
EAC (formerly Gost-R) | Yes | Yes |
Railway application | | |
| Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B | |
Use in hazardous areas | | |
| No | Yes |
Ambient conditions | | |
Ambient temperature during operation | | |
| -25C; = Tmin | -25C; = Tmin |
| 60C; = Tmax; the rated temperature range of -25 ... +55 C (T1) applies for the use on railway vehicles according to EN50155 | 70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use |
Ambient temperature during storage/transportation | | |
| -40C | -40C |
| 70C | 70C |
Altitude during operation relating to sea level | | |
| | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | |
| 100%; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100%; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | | |
Use in stationary industrial systems | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres! | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Configuration | | |
Configuration software | | |
| Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 | Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
| No | No |
Programming | | |
| see instruction list | see instruction list |
| 8 | 8 |
| see instruction list | see instruction list |
| see instruction list | see instruction list |
Programming language | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Know-how protection | | |
| Yes | Yes |
| Yes; With S7 block Privacy | Yes; With S7 block Privacy |
Dimensions | | |
Width | 120mm | 120mm |
Height | 125mm | 125mm |
Depth | 130mm | 130mm |
Weights | | |
Weight, approx. | 680g | 680g |