Installation type/mounting | | | | |
Mounting | on 35 mm DIN rail, 4 spacing units wide | on 35 mm DIN rail, 4 spacing units wide | on 35 mm DIN rail, 4 spacing units wide | on 35 mm DIN rail, 4 spacing units wide |
Supply voltage | | | | |
Rated value (DC) | | | | |
| | Yes | | |
| Yes | Yes | Yes | |
| | | | Yes |
| | | | Yes |
permissible range, lower limit (DC) | 20.4 V; 22 V @ >55 °C | 10.8 V; 11 V @ >55 °C | 20.4 V; 22 V @ >55 °C | 100 V |
permissible range, upper limit (DC) | 28.8 V; 27.5 V @ >55 °C | 28.8 V; 27.5 V @ >55 °C | 28.8 V; 27.5 V @ >55 °C | 253 V |
Rated value (AC) | | | | |
| | | Yes | |
| | | | Yes |
| | | | Yes |
Time of day | | | | |
Time switching clocks | | | | |
| 190 | 8 | 8 | 8 |
| 80 h | 80 h | 80 h | 80 h |
Digital inputs | | | | |
Number of digital inputs | 8; Of which 4 can be used in analog mode (0 to 10 V) | 8; Of which 4 can be used in analog mode (0 to 10 V) | 8 | 8 |
Digital outputs | | | | |
Number of digital outputs | 4; Transistor | 4; Relays | 4; Relays | 4; Relays |
Short-circuit protection | Yes; electrical (1 A) | No; external fusing necessary | No; external fusing necessary | No; external fusing necessary |
Output current | | | | |
| 0.3 A; 0.2 A @ > 55 °C; 0.3 A @ > 55 °C & < 15 s | | | |
Relay outputs | | | | |
Switching capacity of contacts | | | | |
| | 3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s | 3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s | 3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s |
| | 10 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s | 10 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s | 10 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s |
EMC | | | | |
Emission of radio interference acc. to EN 55 011 | | | | |
| Yes; Radio interference suppression according to EN55011, Limit Value Class B | Yes | Yes | Yes |
Degree and class of protection | | | | |
Degree of protection acc. to EN 60529 | | | | |
| Yes | Yes | Yes | Yes |
Standards, approvals, certificates | | | | |
CSA approval | No | No | No | No |
UL approval | Yes; File: E120869 // Tmax = 55 °C | Yes; File: E120869 // Tmax = 55 °C | Yes; File: E120869 // Tmax = 55 °C | Yes; File: E120869 // Tmax = 55 °C |
FM approval | No | No | No | No |
developed in accordance with IEC 61131 | Yes | Yes | Yes | Yes |
according to VDE 0631 | Yes | Yes | Yes | Yes |
Marine approval | No | No | No | No |
Ambient conditions | | | | |
Ambient temperature during operation | | | | |
| -40 °C; = Tmin | -40 °C; = Tmin | -40 °C; = Tmin | -40 °C; = Tmin |
| 70 °C; = Tmax; 55 °C @ UL/cUL use | 70 °C; = Tmax; 55 °C @ UL/cUL use | 70 °C; = Tmax; 55 °C @ UL/cUL use | 70 °C; = Tmax; 55 °C @ UL/cUL use |
Altitude during operation relating to sea level | | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) |
Relative humidity | | | | |
| 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) | 100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state) |
Use in stationary industrial systems | | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Dimensions | | | | |
Width | 72 mm | 72 mm | 72 mm | 72 mm |
Height | 90 mm | 90 mm | 90 mm | 90 mm |
Depth | 55 mm | 55 mm | 55 mm | 55 mm |