General information | | | |
Product type designation | IM 153-1 DP ST | IM 153-2 | IM 153-2 HF |
Firmware version | | V6.0.0 | V6.0.0 |
Vendor identification (VendorID) | 801Dh | 801Eh | 801Eh |
Supply voltage | | | |
Rated value (DC) | | | |
| Yes | Yes | Yes |
permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V |
external protection for power supply lines (recommendation) | not necessary | 2,5 A | 2,5 A |
Mains buffering | | | |
| 5 ms | 5 ms | 5 ms |
Input current | | | |
Current consumption, max. | 350 mA; at 24 V DC | 650 mA; with 24 V DC supply | 650 mA; with 24 V DC supply |
Inrush current, typ. | 2.5 A | 3 A | 3 A |
IІt | 0.1 AІ·s | 0.1 AІ·s | 0.1 AІ·s |
Output voltage | | | |
Rated value (DC) | 5 V | | |
Output current | | | |
for backplane bus (5 V DC), max. | 1 A | 1.5 A | 1.5 A |
Power loss | | | |
Power loss, typ. | 3 W | 5.5 W | 5.5 W |
Address area | | | |
Addressing volume | | | |
| 128 byte | 244 byte | 244 byte |
| 128 byte | 244 byte | 244 byte |
Hardware configuration | | | |
Number of modules per DP slave interface, max. | 8 | 12 | 12 |
Time stamping | | | |
Accuracy | | 1 ms; 1ms at up to 8 modules; 10ms at up to 12 modules | 1 ms; 1ms at up to 8 modules; 10ms at up to 12 modules |
Number of message buffers | | 15 | 15 |
Messages per message buffer | | 20 | 20 |
Number of stampable digital inputs, max. | | 128; Max. 128 signals/station; max. 32 signals/slot | 128; Max. 128 signals/station; max. 32 signals/slot |
Time format | | RFC 1119 | RFC 1119 |
Time resolution | | 0.466 ns | 0.466 ns |
Time interval for transmitting the message buffer if a message is present | | 1 000 ms | 1 000 ms |
Time stamp on signal change | | rising / falling edge as signal entering or exiting | rising / falling edge as signal entering or exiting |
Interfaces | | | |
Transmission procedure | RS 485 | RS 485 | RS 485 |
Interface physics, RS 485 | Yes | Yes | Yes |
Interface physics, FOC | No | No | No |
PROFIBUS DP | | | |
| 1 to 125 permitted | 1 to 125 permitted | 1 to 125 permitted |
| Yes | Yes | Yes |
| 90 mA | 70 mA | 70 mA |
| 12 Mbit/s | 12 Mbit/s | 12 Mbit/s |
| Yes | Yes | Yes |
| Yes | Yes | Yes |
| Yes; Sender | Yes; as publisher with all IO, as subscriber with F-IO only | Yes; as publisher with all IO, as subscriber with F-IO only |
| 9-pin sub D socket | 9-pin sub D | 9-pin sub D |
1. Interface | | | |
DP slave | | | |
| (for DPV1) SIEM801D.GSD; SI01801D.GSG | SI05801E.GSG | SI05801E.GSG |
| Yes | Yes | Yes |
Protocols | | | |
Bus protocol/transmission protocol | PROFIBUS DP to EN 50170 | PROFIBUS DP to EN 50170 | PROFIBUS DP to EN 50170 |
Potential separation | | | |
Potential separation exists | Yes | Yes | Yes |
Isolation | | | |
Isolation tested with | Isolation voltage 500 V | Isolation voltage 500 V | Isolation voltage 500 V |
Degree and class of protection | | | |
IP degree of protection | IP20 | IP20 | IP20 |
Standards, approvals, certificates | | | |
CE mark | Yes | Yes | Yes |
UL approval | Yes; File E239877 | | |
FM approval | Yes; CofC 3028431 | | |
RCM (formerly C-TICK) | Yes | | |
KC approval | Yes | | |
EAC (formerly Gost-R) | Yes | | |
Railway application | | | |
| | Yes; T1 Category 1 Class A/B horizontal mounting position | |
Ambient conditions | | | |
Ambient temperature during operation | | | |
| -40 °C; = Tmin | -25 °C; = Tmin | -40 °C; = Tmin; Startup @ -25 °C |
| 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use | 60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155 | 70 °C; = Tmax |
| -25 °C | -25 °C | -25 °C |
Ambient temperature during storage/transportation | | | |
| -40 °C | -40 °C | -40 °C |
| 70 °C | 70 °C | 70 °C |
Altitude during operation relating to sea level | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | | | |
Use in stationary industrial systems | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Configuration | | | |
Configuration software | | | |
| STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file | Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file | Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file |
Dimensions | | | |
Width | 40 mm | 40 mm | 40 mm |
Height | 125 mm | 125 mm | 125 mm |
Depth | 117 mm | 117 mm | 117 mm |
Weights | | | |
Weight, approx. | 360 g | 360 g | 360 g |