Article number

6AG1331-1KF02-7AB0

6AG1331-7KB02-2AB0

6AG1331-7KF02-2AB0

SIPLUS SM331 8AI

SIPLUS SM331 2AE

SIPLUS SM331 8AI

Supply voltage

Load voltage L+

  • Rated value (DC)

24V

24V; A power supply according to EN 50155 shall be used for railway applications

  • Reverse polarity protection

Yes

Yes

Input current

from load voltage L+ (without load), max.

80mA

200mA

from backplane bus 5 V DC, max.

90mA

50mA

50mA

Power loss

Power loss, typ.

0.4W

1.3W

1W

Analog inputs

Number of analog inputs

8

2

8

  • For resistance measurement

8

1

4

permissible input voltage for voltage input (destruction limit), max.

30V; 12 V continuous, 30 V for max. 1 s

20V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)

20V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)

permissible input current for current input (destruction limit), max.

40mA

40mA

40mA

Input ranges

  • Voltage

Yes

Yes

Yes

  • Current

Yes

Yes

Yes

  • Thermocouple

No

Yes

Yes

  • Resistance thermometer

Yes

Yes

Yes

  • Resistance

Yes

Yes

Yes

Input ranges (rated values), voltages

  • 0 to +10 V

Yes

No

No

  • Input resistance (0 to 10 V)

100kΩ

  • 1 V to 5 V

Yes

Yes

Yes

  • Input resistance (1 V to 5 V)

100kΩ

100kΩ

100kΩ

  • 1 V to 10 V

No

No

No

  • -1 V to +1 V

Yes

Yes

Yes

  • Input resistance (-1 V to +1 V)

100kΩ

10MΩ

10MΩ

  • -10 V to +10 V

Yes

Yes

Yes

  • Input resistance (-10 V to +10 V)

100kΩ

100kΩ

100kΩ

  • -2.5 V to +2.5 V

No

Yes

Yes

  • Input resistance (-2.5 V to +2.5 V)

100kΩ

100kΩ

  • -250 mV to +250 mV

No

Yes

Yes

  • Input resistance (-250 mV to +250 mV)

10MΩ

10MΩ

  • -5 V to +5 V

Yes

Yes

Yes

  • Input resistance (-5 V to +5 V)

100kΩ

100kΩ

100kΩ

  • -50 mV to +50 mV

Yes

No

No

  • Input resistance (-50 mV to +50 mV)

100kΩ

  • -500 mV to +500 mV

Yes

Yes

Yes

  • Input resistance (-500 mV to +500 mV)

100kΩ

10MΩ

10MΩ

  • -80 mV to +80 mV

No

Yes

Yes

  • Input resistance (-80 mV to +80 mV)

10MΩ

10MΩ

Input ranges (rated values), currents

  • 0 to 20 mA

Yes

Yes

Yes

  • Input resistance (0 to 20 mA)

100Ω

25Ω

25Ω

  • -10 mA to +10 mA

No

Yes

Yes

  • Input resistance (-10 mA to +10 mA)

25Ω

25Ω

  • -20 mA to +20 mA

Yes

Yes

Yes

  • Input resistance (-20 mA to +20 mA)

100Ω

25Ω

25Ω

  • -3.2 mA to +3.2 mA

No

Yes

Yes

  • Input resistance (-3.2 mA to +3.2 mA)

25Ω

25Ω

  • 4 mA to 20 mA

Yes

Yes

Yes

  • Input resistance (4 mA to 20 mA)

100Ω

25Ω

25Ω

Input ranges (rated values), thermocouples

  • Type B

No

No

  • Type C

No

No

  • Type E

No

Yes

Yes

  • Input resistance (Type E)

10MΩ

10MΩ

  • Type J

No

Yes

Yes

  • Input resistance (type J)

10MΩ

10MΩ

  • Type K

No

Yes

Yes

  • Input resistance (Type K)

10MΩ

10MΩ

  • Type L

No

No

No

  • Type N

No

Yes

Yes

  • Input resistance (Type N)

10MΩ

10MΩ

  • Type R

No

No

No

  • Type S

No

No

No

  • Type T

No

No

No

  • Type U

No

No

No

  • Type TXK/TXK(L) to GOST

No

No

No

Input ranges (rated values), resistance thermometer

  • Cu 10

No

No

No

  • Ni 100

Yes; Standard/climate

Yes

Yes; Standard

  • Input resistance (Ni 100)

100MΩ

10MΩ; Standard

10MΩ

  • Ni 1000

Yes

No

  • Input resistance (Ni 1000)

100MΩ

  • LG-Ni 1000

Yes; Standard/climate

No

  • Input resistance (LG-Ni 1000)

100MΩ

  • Ni 120

No

No

  • Ni 200

No

No

  • Ni 500

No

No

  • Pt 100

Yes; Standard/climate

Yes

Yes; Standard

  • Input resistance (Pt 100)

100MΩ

10kΩ; Standard

10MΩ

  • Pt 1000

No

No

  • Pt 200

No

No

  • Pt 500

No

No

Input ranges (rated values), resistors

  • 0 to 150 ohms

No

Yes

Yes

  • Input resistance (0 to 150 ohms)

10MΩ

10MΩ

  • 0 to 300 ohms

No

Yes

Yes

  • Input resistance (0 to 300 ohms)

10MΩ

10MΩ

  • 0 to 600 ohms

Yes

Yes

Yes

  • Input resistance (0 to 600 ohms)

100MΩ

10MΩ

10MΩ

  • 0 to 6000 ohms

Yes

No

No

  • Input resistance (0 to 6000 ohms)

100MΩ

Thermocouple (TC)

Temperature compensation

  • parameterizable

Yes

Yes

  • internal temperature compensation

Yes

Yes

  • external temperature compensation with compensations socket

Yes

Yes

Characteristic linearization

  • parameterizable

Yes

Yes

Yes

  • for thermocouples

Type E, J, K, L, N

Type E, J, K, L, N

  • for resistance thermometer

yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.

Pt100 (standard, climatic range), Ni100 (standard, climatic range)

Pt100 (standard, climatic range), Ni100 (standard, climatic range)

Cable length

  • shielded, max.

200m; max. 50 m at 50 mV

200m; 50 m at 80 mV and thermocouples

200m; 50 m at 80 mV and thermocouples

Analog value generation for the inputs

Measurement principle

integrating

integrating

integrating

Integration and conversion time/resolution per channel

  • Resolution with overrange (bit including sign), max.

13bit

15bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign

15bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign

  • Integration time, parameterizable

Yes; 60 / 50 ms

Yes; 2,5 / 16,67 / 20 / 100 ms

Yes; 2,5 / 16,67 / 20 / 100 ms

  • Basic conversion time (ms)

66 / 55 ms

  • Interference voltage suppression for interference frequency f1 in Hz

50 / 60 Hz

400 / 60 / 50 / 10 Hz

400 / 60 / 50 / 10 Hz

Encoder

Connection of signal encoders

  • for current measurement as 2-wire transducer

Yes; with external supply

Yes

Yes

  • for current measurement as 4-wire transducer

Yes

Yes

Yes

  • for resistance measurement with two-wire connection

Yes

Yes

Yes

  • for resistance measurement with three-wire connection

Yes

Yes

Yes

  • for resistance measurement with four-wire connection

Yes

Yes

Yes

Errors/accuracies

Operational error limit in overall temperature range

  • Voltage, relative to input range, (+/-)

0.6%; 0.6 % (5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.5 % (50 mV, 500 mV, 1 V) @ 0 ... +60 C; 0.7 % (5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.6 % (50 mV, 500 mV, 1 V) @ -25 ... +70 C

1%; 1% (80 mV); 0.6% (250 mV to 1 000 mV); 0.8% (2.5 V to 10 V) @ 0 ... +60 C; 1.3% (80 mV); 0.8% (250 mV to 1 000 mV); 1% (2.5 V to 10 V) @ -25 ... +70 C

1%; 1% (80 mV); 0.6% (250 mV to 1 000 mV); 0.8% (2.5 V to 10 V) @ 0 ... +60 C; 1.3% (80 mV); 0.8% (250 mV to 1 000 mV); 1% (2.5 V to 10 V) @ -25 ... +70 C

  • Current, relative to input range, (+/-)

0.5%; @ 0 ... +60 C; 0.6% @ -25 ... +70 C; 20 mA, 0 to 20 mA, 4 to 20 mA

0.7%; @ 0 ... +60 C; 0.9% @ -25 ... +70 C; from 3.2 mA to 20 mA

0.7%; @ 0 ... +60 C; 0.9% @ -25 ... +70 C; from 3.2 mA to 20 mA

  • Resistance, relative to input range, (+/-)

0.5%; @ 0 ... +60 C; 0.6% @ -25 ... +70 C; 0 to 6 kohm, 0 to 600 kohm

0.7%; @ 0 ... +60 C; 0.9% @ -25 ... +70 C; 150, 300, 600 ohm

0.7%; @ 0 ... +60 C; 0.9% @ -25 ... +70 C; 150, 300, 600 ohm

  • Resistance thermometer, relative to input range, (+/-)

1 Kelvin (Pt100, Ni100, climate; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climate); 1.2 Kelvin (Pt100, Ni100, standard) @ 0 ... +60 C; 1.2 Kelvin (Pt100, Ni100, climate; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climate); 1.4 Kelvin (Pt100, Ni100, standard) @ -25 ... +70 C

0.7%; 0.7 % (Pt100 / Ni100); 0.8 % (Pt100 climate) @ 0 ... +60 C; 0.9 % (Pt100 / Ni100); 1 % (Pt100 climate) @ -25 ... +70 C

0.7%; 0.7 % (Pt100 / Ni100); 0.8 % (Pt100 climate) @ 0 ... +60 C; 0.9 % (Pt100 / Ni100); 1 % (Pt100 climate) @ -25 ... +70 C

Basic error limit (operational limit at 25 C)

  • Voltage, relative to input range, (+/-)

0.4%; 0.4% (5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (50 mV, 500 mV, 1 V)

0.6%; 0.6% (80 mV, 2.5 V to 10 V); 0.4% (250 mV to 1 000 mV)

0.6%; 0.4 % (250 mV to 1 000 mV); 0.6 % (2.5 mV to 10 mV); 0.7 % (80 mV)

  • Current, relative to input range, (+/-)

0.3%; 20 mA, 0 to 20 mA, 4 to 20 mA

0.5%; 3.2 to 20 mA

0.5%; 3.2 to 20 mA

  • Resistance, relative to input range, (+/-)

0.3%; 0 to 6 kohms, 0 to 600 kohms

0.5%; 150, 300, 600 Ohm

0.5%; 150, 300, 600 Ohm

  • Resistance thermometer, relative to input range, (+/-)

1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)

0.6%; 0.5% (Pt100/ Ni100), 0.6% (Pt100 climate)

0.6%; 0.5% (Pt100/ Ni100), 0.6% (Pt100 climate)

Interrupts/diagnostics/status information

Diagnostic functions

No

Yes; Parameterizable

Yes; Parameterizable

Alarms

  • Diagnostic alarm

No

Yes

Yes; Parameterizable, channels 0 and 2

  • Limit value alarm

No

Yes; Parameterizable, channel 0

Yes; Parameterizable

Diagnostic messages

  • Diagnostic information readable

No

Yes

Yes

Diagnostics indication LED

  • Group error SF (red)

No

Yes

Yes

Potential separation

Potential separation analog inputs

  • between the channels and backplane bus

Yes

Yes

Yes

Isolation

Isolation tested with

500 V DC

500 V DC

500 V DC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes; CofC 3028431

Yes; CofC 3028431

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Railway application

  • EN 50121-4

No

No

No

  • EN 50155

No

No

Yes; T1 Category 1 Class A/B horizontal mounting position

Ambient conditions

Ambient temperature during operation

  • min.

-25C

-25C; = Tmin

-25C; = Tmin

  • max.

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

70C; = Tmax; 60 C @ UL/cUL, ATEX and FM use

70C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/ULhaz/ATEX/FM use applies

Ambient temperature during storage/transportation

  • min.

-40C

-40C

  • max.

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

40-pin

20-pin

20-pin

Dimensions

Width

40mm

40mm

40mm

Height

125mm

125mm

125mm

Depth

117mm

120mm

120mm

Weights

Weight, approx.

250g

250g

250g


Article number

6AG1331-7NF00-2AB0

6AG1331-7NF10-2AB0

6AG1331-7PF01-4AB0

6AG1331-7PF11-4AB0

SIPLUS S7-300 SM331 8AI - 40pol

SIPLUS SM331 8AI - 40pol

SIPLUS SM331 8AI

SIPLUS S7-300 SM331 8AI 40pol

Supply voltage

Load voltage L+

  • Rated value (DC)

24V

24V

24V

  • Reverse polarity protection

Yes

Yes

Yes

Input current

from load voltage L+ (without load), max.

200mA

240mA

240mA

from backplane bus 5 V DC, max.

130mA

100mA

100mA

100mA

Power loss

Power loss, typ.

0.6W

3W

4.6W

3W

Analog inputs

Number of analog inputs

8

8

8

8

  • For resistance measurement

8

permissible input voltage for voltage input (destruction limit), max.

50V; Permanent

75V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)

75V; 35 V continuous, 75 V for max. 1 s (mark to space ratio 1:20)

75V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)

permissible input current for current input (destruction limit), max.

32mA

40mA

Input ranges

  • Voltage

Yes

Yes

No

No

  • Current

Yes

Yes

No

No

  • Thermocouple

No

No

No

Yes

  • Resistance thermometer

No

No

Yes

No

  • Resistance

No

No

Yes

No

Input ranges (rated values), voltages

  • 0 to +10 V

No

No

No

No

  • 1 V to 5 V

Yes

Yes

No

No

  • Input resistance (1 V to 5 V)

2MΩ

10MΩ

  • 1 V to 10 V

No

No

No

No

  • -1 V to +1 V

No

No

No

No

  • -10 V to +10 V

Yes

Yes

No

No

  • Input resistance (-10 V to +10 V)

2MΩ

10MΩ

  • -2.5 V to +2.5 V

No

No

No

No

  • -250 mV to +250 mV

No

No

No

No

  • -5 V to +5 V

Yes

Yes

No

No

  • Input resistance (-5 V to +5 V)

2MΩ

10MΩ

  • -50 mV to +50 mV

No

No

No

No

  • -500 mV to +500 mV

No

No

No

No

  • -80 mV to +80 mV

No

No

No

No

Input ranges (rated values), currents

  • 0 to 20 mA

Yes

Yes

No

No

  • Input resistance (0 to 20 mA)

250Ω

250Ω

  • -10 mA to +10 mA

No

No

  • -20 mA to +20 mA

Yes

Yes

No

No

  • Input resistance (-20 mA to +20 mA)

250Ω

250Ω

  • -3.2 mA to +3.2 mA

No

No

No

No

  • 4 mA to 20 mA

Yes

Yes

No

No

  • Input resistance (4 mA to 20 mA)

250Ω

250Ω

Input ranges (rated values), thermocouples

  • Type B

No

No

No

Yes

  • Type C

No

No

No

Yes

  • Type E

No

No

No

Yes

  • Type J

No

No

No

Yes

  • Type K

No

No

No

Yes

  • Type L

No

No

No

Yes

  • Type N

No

No

No

Yes

  • Type R

No

No

No

Yes

  • Type S

No

No

No

Yes

  • Type T

No

No

No

Yes

  • Type U

No

No

No

Yes

  • Type TXK/TXK(L) to GOST

No

No

No

Yes

Input ranges (rated values), resistance thermometer

  • Cu 10

No

No

Yes

No

  • Ni 100

No

No

Yes

No

  • Ni 1000

No

No

Yes

No

  • LG-Ni 1000

No

No

Yes

No

  • Ni 120

No

No

Yes

No

  • Ni 200

No

No

Yes

No

  • Ni 500

No

No

Yes

No

  • Pt 100

No

No

Yes

No

  • Pt 1000

No

No

Yes

No

  • Pt 200

No

No

Yes

No

  • Pt 500

No

No

Yes

No

Input ranges (rated values), resistors

  • 0 to 150 ohms

No

No

Yes

No

  • 0 to 300 ohms

No

No

Yes

No

  • 0 to 600 ohms

No

No

Yes

No

  • 0 to 6000 ohms

No

No

No

Thermocouple (TC)

Temperature compensation

  • parameterizable

Yes

  • internal temperature compensation

Yes

  • external temperature compensation with compensations socket

Yes

  • external temperature compensation with Pt100

Yes

Characteristic linearization

  • parameterizable

Yes

Yes

  • for thermocouples

Type B, E, J, K, L, N, R, S. T, U, C

  • for resistance thermometer

Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10; (standard/climate)

Cable length

  • shielded, max.

200m

200m

200m

100m

Analog value generation for the inputs

Measurement principle

integrating

integrating

integrating

integrating

Integration and conversion time/resolution per channel

  • Resolution with overrange (bit including sign), max.

16bit; Unipolar: 15/15/15/15 bit; bipolar: 15 bit + sign/15 bit + sign/15 bit + sign/15 bit + sign

16bit; Unipolar: 15/15/15/15 bit; bipolar: 15 bit + sign/15 bit + sign/15 bit + sign/15 bit + sign

16bit; Two's complement

16bit; Two's complement

  • Integration time, parameterizable

Yes; 10/ 16.67/ 20/ 100 ms

Yes; 23 / 72 / 83 / 95 ms

Yes

Yes

  • Basic conversion time (ms)

10 ms (4-channel mode); 95/83/72/23 ms (8-channel mode)

up to 4 channels: 10 ms per module, over 5 channels: 190 ms per module, 8 channels: 80 ms

up to 4 channels: 10 ms per module, over 5 channels: 190 ms per module, 8 channels: 80 ms

  • Interference voltage suppression for interference frequency f1 in Hz

400 / 60 / 50 / 10 Hz

400 / 60 / 50 Hz, combinations of 400, 60, 50 Hz

400 / 60 / 50 Hz

400 / 60 / 50 Hz

Encoder

Connection of signal encoders

  • for current measurement as 2-wire transducer

Yes; with external transmitter; possible with separate supply for transmitter

Yes; with external transmitter, current supply; possible with separate supply for transmitter

  • for current measurement as 4-wire transducer

Yes

Yes

  • for resistance measurement with two-wire connection

Yes; without resistance correction

  • for resistance measurement with three-wire connection

Yes

  • for resistance measurement with four-wire connection

Yes

Errors/accuracies

Operational error limit in overall temperature range

  • Voltage, relative to input range, (+/-)

0.1%; @ Ucm = 0 V; @ Ucm = 50 V: 0.7 % - @ 0 ... +60 C; 0.5% @ Ucm = 0 V; @ Ucm = 50 V: 0.9% - @ -25 ... +70 C;

0.1%; @ 0 ... +60 C; 0.2% @ -25 ... +60 C

1 K

  • Current, relative to input range, (+/-)

0.3%; @ Ucm = 0 V; @ Ucm = 50 V: 0.4 % @ 0 ... +60 C; 0.5% @ Ucm = 0 V; @ Ucm = 50 V: 0.6% @ -25 ... +70 C

0.1%; @ 0 ... +60 C; 0.2% @ -25 ... +60 C

  • Resistance, relative to input range, (+/-)

0.1%

  • Resistance thermometer, relative to input range, (+/-)

1 K

Basic error limit (operational limit at 25 C)

  • Voltage, relative to input range, (+/-)

0.05%

0.05%

  • Current, relative to input range, (+/-)

0.05%

0.05%

  • Resistance, relative to input range, (+/-)

0.05%

  • Resistance thermometer, relative to input range, (+/-)

0.5 K

Interrupts/diagnostics/status information

Diagnostic functions

Yes; Parameterizable

Yes; Parameterizable

Yes; Parameterizable

Yes; Parameterizable

Alarms

  • Diagnostic alarm

Yes; Parameterizable

Yes; Parameterizable

Yes; Parameterizable per group

Yes; Parameterizable per group

  • Limit value alarm

Yes; Parameterizable, channels 0 and 2

Yes; Parameterizable all channels (end of cycle interrupt is also supported across modules)

Yes; Parameterizable

Yes; Parameterizable

  • Hardware interrupt

Yes; Parameterizable, channels 0 to 7 (on exceeding limit value), at end of cycle

Yes; Parameterizable, channels 0 to 7

Yes; Parameterizable, channels 0 to 7

Diagnostic messages

  • Diagnostic information readable

Yes

Yes

Yes

Yes

Diagnostics indication LED

  • Group error SF (red)

Yes

Yes

Yes

Yes

Potential separation

Potential separation analog inputs

  • between the channels and backplane bus

Yes

Yes

Yes

Yes

Isolation

Isolation tested with

500 V DC

500 V AC

500 V DC

500 V DC

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

UL approval

Yes; File E239877

Yes; File E239877

Yes; File E239877

Yes; File E239877

FM approval

Yes

Yes; CofC 3028431

Yes; CofC 3028431

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Yes

Railway application

  • EN 50121-4

No

No

No

No

  • EN 50155

Yes; T1 Category 1 Class A/B horizontal mounting position

No

No

No

Ambient conditions

Ambient temperature during operation

  • min.

-25C; = Tmin

-25C; = Tmin

0C; = Tmin

0C; = Tmin

  • max.

70C; = Tmax; for use on railway vehicles according to EN 50155, the rated temperature range -25 ... +55 C (T1) or 60 C @ UL/UL hazardous use applies

60C; = Tmax

60C; = Tmax

60C; = Tmax

Ambient temperature during storage/transportation

  • min.

-40C

-40C

-40C

-40C

  • max.

70C

70C

70C

70C

Altitude during operation relating to sea level

  • Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

  • With condensation, tested in accordance with IEC 60068-2-38, max.

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

100%; RH incl. condensation/frost (no commissioning under condensation conditions)

Resistance

Use in stationary industrial systems

  • to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • to mechanically active substances according to EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Connection method

required front connector

40-pin

40-pin

40-pin

40-pin

Dimensions

Width

40mm

40mm

40mm

40mm

Height

125mm

125mm

125mm

125mm

Depth

117mm

120mm

120mm

120mm

Weights

Weight, approx.

272g

272g

272g

272g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS -

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK -
2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Automation technology for extreme conditions SIMATIC industrial automation systems Controllers SIPLUS LOGO! logic module Basic Controller Advanced Controller SIPLUS S7-1500 SIPLUS S7-300 SIPLUS S7-300 central processing units SIPLUS S7-300 I/O modules SIPLUS S7-300 digital modules SIPLUS S7-300 analog modules SIPLUS S7-300 SM 331 SIPLUS S7-300 SM 332 SIPLUS S7-300 SM 334 SIPLUS S7-300 F digital/analog modules SIPLUS S7-300 Ex digital modules SIPLUS S7-300 Ex analog modules SIPLUS S7-300 function modules SIPLUS S7-300 communication SIPLUS S7-300 special modules SIPLUS S7-300 IM365 SIPLUS power supplies SIPLUS S7-400 Distributed Controller SIPLUS IO systems SIMOTION Motion Control System Process control systems Operator control and monitoring systems Industrial communication Industrial controls Power supplies SIPLUS add-ons Telecontrol systems for comprehensive applications IO systems for heating elements Automatic door controllers Condition Monitoring Systems Time synchronization Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.