SIWAREX R load cells, SP series | |
Possible applications | Smaller conveyor scales, small platform scales |
Model | Single point |
Rated load Emax | 6/12 kg |
Accuracy class according to OIML R60 | C3 |
Maximum scale interval nlc | 3000 |
Minimum scale interval vmin | Emax./12 000 |
Combined error Fcomb | ≤ ± 0.02 % Cn |
Repeatability Fv | ≤ ± 0.01 % Cn |
Return of zero signal | ≤ ± 0.0167 % Cn1) |
Creep error Fcr | |
| ≤ ± 0.0245 % Cn1) |
| ≤ ± 0.0053 % Cn1) |
Temperature effect | |
Zero signal TKo | ≤ ± 0.0058 % Cn/5 K |
Characteristic value TKc | ≤ ± 0.0045 % Cn/5 K |
Min. dead load Emin | 0 % Emax |
Maximum working load Lu | 150 % Emax |
Ultimate load Ld | 300 % Emax |
Maximum safe side load Llq | 100 % Emax |
Rated measuring path hn at Emax 6 kg | 0.24 ± 0.02 mm |
Rated measuring path hn at Emax 12 kg | 0.19 ± 0.01 mm |
Supply voltage Usr (reference value) | 10 V |
Supply voltage (range) | 5 ... 15 V |
Rated characteristic value Cn | 2 mV/V |
Tolerance Dc of characteristic value | ± 10 % |
Tolerance Do of zero signal | ≤ ± 1 % Cn |
Input resistance Re | 410 О© ± 6 О© |
Output resistance Ra | 350 О© ± 7 О© |
Insulation resistance Ris | ≥ 5000 MΩ |
Rated temperature range Btn | -10 ... +40 °C |
Operating temperature range Btu | -40 ... +80 °C |
Storage temperature range Bts | -40 ... +90 °C |
Sensor material (DIN) | Stainless steel, mat. no. 1.4542 |
Degree of protection to EN 60529 | IP66/IP68 |
Maximum tightening torque of the fixing screws | 6 Nm |
Ex protection to ATEX (optional) | II 2 G EEx ib IIC T6/T4 II 3 G EEx nA / nL IIC T6/T4 II 1D / 2D / 3D T 70 °C |
Cable connection | |
Function | Color |
| |
| |
- SIG + (measured signal +)
| |
- SIG - (measured signal -)
| |
| |
| |
- Shield (not connected to housing)
| |