Mode of operation | |
Measuring principle | Belt scale integrator |
Typical application | - Compatible with Milltronics belt scales or equivalent 1, 2, 41), or 61) load cell scales
- Compatible with LVDT equipped scales, with use of optional interface board (remotely mounted)
|
Inputs | |
Load cell | 0 ... 45 mV DC per load cell |
Speed sensor | |
| - 0 ... 5 V low, 5 ... 15 V high 1 ... 3 000 Hz, or
- Open collector switch, or
- Relay dry contact
|
Auto zero | Dry contact from external device |
mA | See optional mA I/O board1) |
Auxiliary | 5 discrete inputs for external contacts, each programmable for either: display scrolling, totalizer 1 reset, zero, span, multi-span, print, batch reset, PID function or online calibration, 2nd speed sensor |
Outputs (load and speed) | |
mA | Programmable 0/4 ... 20 mA, for rate, optically isolated, 0.1 % of 20 mA resolution, 750 О© load max. (see optional mA I/O board) |
Load cell | 10 V DC compensated excitation for strain gauge type, 6 cells max, 150 mA max. |
Speed sensor(s) | 12 V DC, 150 mA max. excitation |
Remote totalizer 1 | - Contact closure 10 ... 300 ms duration
- Solid state relay contact 30 V DC, 100 mA max.
- Max. contact on-resistance = 36 ohms
- Max. off-state leakage = 1 uA
|
Remote totalizer 2 | - Contact closure 10 ... 300 ms duration
- Solid state relay contact rated 240 V AC/DC, 100 mA max.
- Max. contact on-resistance = 36 ohms
- Max. off-state leakage = 1 uA
|
Relay output | 5 alarm/control relays, 1 SPST Form A relay contact per relay, rated 5 A at 250 V AC, non-inductive or 30 V DC |
Measuring accuracy | |
Resolution | 0.02 % of full scale |
Accuracy | 0.1 % of full scale |
Rated operating conditions | |
Ambient conditions | |
Location | Indoor/outdoor |
Ambient temperature | -20 ... +50 °C (-5 … +122 °F) |
Relative humidity/ingress protection | Suitable for outdoor/Type 4X/NEMA 4X/IP65 |
Installation category | II |
Pollution degree | 4 |
Design | |
Material (enclosure) | Polycarbonate |
Dimensions | 209 W x 285 H x 92 D mm (8.2 W x 11.2 H x 3.6 D inch) |
Weight | 2.6 kg (5.7 lb) |
Power supply | |
Standard | AC version - 100 ... 240 V AC, ±10 %, 50/60 Hz, 55 VA max.
- Fuse FU3 = 2AG, 2 AMP, 250 V Slo Blo
DC version - 10 ... 30 V DC, 26 W max.
- Fuse FU2 = 3.75 A resettable (not user replaceable)
|
Controls and displays | |
Displays | Illuminated 5 x 7 dot matrix liquid crystal display with 2 lines of 40 characters each |
Programming | Via local keypad and/or Dolphin Plus interface |
Memory | Program and parameters stored in non-volatile Flash memory, upgradeable via Dolphin Plus interface |
Communications | - Two RS 232 ports
- One RS 485 port
- SmartLinx compatible
|
mA I/O board | |
Inputs | 2 programmable 0/4 … 20 mA for PID control and on-line calibration, optically isolated, 0.1 % of 20 mA resolution, 200 Ω input impedance |
Outputs | 2 programmable 0/4 … 20 mA for PID control, rate, load, and speed output, optically isolated, 0.1 % of 20 mA resolution, 750 Ω load max |
Output supply | Isolated 24 V DC at 50 mA, short circuit protected |
Approvals | |
BW500 | CE, CSAUS/C, FM, Measurement Canada, NTEP, MID, OIML, GOST, RCM, EAC, SABS, STAMEQ, KCC |
BW500/L | CE, CSAUS/C, FM, RCM, EAC, KCC |
Options | - Speed sensor: MD-36/36A, MD-256, SITRANS WS300, TASS, or RBSS, or compatible
- Dolphin Plus: Windows based software interface. Refer to associated product documentation.
- SmartLinx Modules: protocol specific modules for interface with popular industrial communications systems. Refer to product documentation.
- LVDT interface card: for interface with LVDT based scales
|