Technical specifications | |
Mode of operation | |
Measuring principle | Strain gauge load cells measuring load on belt conveyor idler(s) |
Typical application | |
| Control in fractionated stone blending tunnels |
| Custody transfer |
Measurement accuracy | |
Accuracy1) | |
| ± 0.5 % or better of totalization over 20 … 100 % operating range |
| ± 0.25 % or better of totalization over 20 … 100 % operating range |
Note: available with system specification option D only | ± 0.125 % or better of totalization over 25 … 100 % operating range |
Repeatability | ± 0.1 % |
Medium conditions | |
Material temperature | -50 … +175 °C (-58 … +347 °F) |
Belt design | |
Belt width | - 18 … 96 inch in CEMA sizes
- Equivalent to 500 … 2 000 mm in metric size
- Refer to dimensions section
|
Belt speed | Up to 5 m/s (1 000 fpm)2) |
Capacity | Up to 12 000 t/h (13 200 STPH) at maximum belt speed. Please contact a Siemens representative for higher rates. |
Conveyor incline | - ± 20° from horizontal, fixed incline
- Up to ± 30° with reduced accuracy3)
|
Idlers | |
Idler profile | - Flat to 35°
- Up to 45° with reduced accuracy3)
|
Idler diameter | 50 … 180 mm (2 … 7 inch) |
Idler spacing | 0.5 … 1.5 m (1.5 … 5.0 ft) |
Load cell | |
Construction | Stainless steel construction with 304 (1.4301) stainless steel cover Strain gauge protection: polybutadiene |
Degree of protection | IP67, IP65 on hazardous approved models |
Cable length | 3 m (10 ft) |
| | Note: to calculate installation cable length subtract 3 048 mm (120 inch) from the "A" dimension |
Excitation | 10 V DC nominal, 15 V DC maximum |
Output | 2 ± 0.002 mV/V excitation (nominal) at rated load cell capacity |
Non-linearity and hysteresis | 0.02 % of rated output |
Non-repeatability | 0.01 % of rated output |
Capacity | |
| 25, 50, 100, 250, 500, 750, 1 000, 1 250, 1 500, 2 000 lb |
Overload | 150 % of rated capacity, ultimate 300 % of rated capacity |
Temperature | - -50 … +75 °C (-58 … +167 °F) operating range
- -40 … +65 °C (-40 … +150 °F) compensated
- -10 ... +40 °C (14 ... 104 °F) compensated on trade approved versions
|
Weight | See dimensions section |
Interconnection wiring (to integrator, per MSI) | < 150 m (500 ft) 18 AWG (0.75 mmІ) 6 conductor shielded cable > 150 m … 300 m (500 ft … 1 000 ft) 18 … 22 AWG (0.75 … 0.34 mmІ), 8 conductor shielded cable |
Approvals | - CSA/FM Class II, Div. 1, Groups E,F,G and Class III
- ATEX II 2D Ex tD A21 IP65 T90 єC
- EAC Ex
- IECEx Ex tD A21 IP65 T90 єC
- CE, RCM, EAC, KCC, CMC, RTN
|
Metrology approvals | Measurement Canada, MID, OIML, SABS4), NTEP5), STAMEQ, GOST |