Mode of operation | |
Measuring principle | Rotating point level switch |
Input | |
Measured variable | High and low and demand |
Output | |
Output signal | |
| Microswitch 5 A at 250 V AC, non-inductive Microswitch SPDT contact 4 A at 30 V DC, non-inductive |
| Standard (1 rpm model): approx. 1.3 seconds Optional process applications (5 rpm model): approx. 0.26 seconds |
Sensitivity | Adjustable via reset force of spring or geometry of measuring vane |
Rated operating conditions | |
Installation conditions | |
| Indoor/outdoor |
Ambient conditions | |
| -25 ... +60 °C (-13 ... +140 °F) |
| III |
| 2 |
Medium conditions | Bulk solids |
| |
| -25 ... +80 °C (-13 ... +176 °F) |
| -25 ... +600 °C (-13 ... +1 112 °F) |
| | Higher temperature version is available. Consult a local sales person for details. For more information, please visit http://www.automation.siemens.com/aspa_app. |
| |
| Max. 0.5 bar g (7.25 psi g) |
| Max. 10 bar g (145 psi g) |
| |
| Can detect down to 100 g/l (6.25 lb/ft3) |
| Can detect down to 15.06 g/l (0.94 lb/ft3) |
Design | |
Material | |
| Epoxy coated aluminum |
- Process connection, measuring shaft and vane
| Stainless steel or aluminum |
Process connection | Thread NPT, BSP, and flange options |
Degree of protection | IP65/Type 4/NEMA 4 |
Conduit entry | 2 x M20 x 1.5 or 2 x Ѕ" NPT |
Power supply | |
Jumper selectable | 115 V AC, ± 15 %, 50 ... 60 Hz, 4 VA or 230 V AC, ± 15 %, 50 Hz, 6 VA, or 48 V AC, or 24 V AC, or 24 V DC, ± 15 %, 2.5 W |
Universal voltage (DPDT replay) | 24 V DC ± 15 % 50 ... 60 Hz, 22 ... 230 V, ± 10 %, max. 10 VA |
Certificates and approvals | - CSA/FM General Purpose
- CE
- CSA/FM Dust Ignition Proof
- ATEX II 1/2 D
- RCM
- IECex
|