Mode of Operation |
Measuring principle | Ultrasonic level measurement |
Measuring range | 0.3 ... 15 m (1 ... 50 ft) |
Measuring points | 1 or 2 |
Input | |
Analog (MultiRanger 200 only) | 0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable |
Discrete | 10 ... 50 V DC switching level Logical 0 ≤ 0.5 V DC Logical 1 = 10 ... 50 V DC Max. 3 mA |
Output | |
EchoMax transducer | 44 kHz |
Ultrasonic transducer | Compatible transducers: ST-H and EchoMax series XPS-10, XPS 15/15F, and XRS-5 |
Relays | Rating 5 A at 250 V AC, non-inductive |
- Version with 1 relay
(MultiRanger 100 only)
| 1 SPST Form A |
| 2 SPST Form A/1 SPDT Form C |
| 4 SPST Form A/2 SPDT Form C |
mA output | 0 ... 20 mA or 4 ... 20 mA |
| 750 О©, isolated |
| 0.1 % of range |
Accuracy | |
Error in measurement | 0.25 % of range or 6 mm (0.24 inch), whichever is greater |
Resolution | 0.1 % of measuring range1) or 2 mm (0.08 inch), whichever is greater |
Temperature compensation | - -50 ... +150 °C (-58 ... +302 °F)
- Integral temperature sensor
- External TS-3 temperature sensor (optional)
- Programmable fixed temperature values
|
Rated operating conditions | |
Installation conditions | |
| Indoor/outdoor |
| II |
| 4 |
Ambient conditions | |
- Ambient temperature (housing)
| -20 ... +50 °C (-4 ... +122 °F) |
Design | |
Weight | |
| 1.37 kg (3.02 lb) |
| 1.50 kg (3.31 lb) |
Material (enclosure) | Polycarbonate |
Degree of protection (enclosure) | |
| IP65/Type 4X/NEMA 4X |
| IP54/Type 3/NEMA 3 |
Electrical connection | |
- Transducer and mA output signal
| 2-core copper conductor, twisted, shielded, 0.5 ... 0.75 mmІ (22 ... 18 AWG), Belden 8760 or equivalent is acceptable |
- Max. separation between transducer and transceiver
| 365 m (1 200 ft) |
Displays and controls | 100 x 40 mm (4 x 1.5 inch) multi-block LCD with backlighting |
Programming | Programming using hand-held programmer, SIMATIC PDM or via PC with Dolphin Plus software |
Power supply | |
AC version | 100 ... 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W) |
DC version | 12 ... 30 V DC (20 W) |
Certificates and approvals | - CE, RCM, EAC, KCC2)
- Lloyd’s Register of Shipping
- ABS Type Approval
- FM, CSAUS/C, UL listed
- CSA Class I, Div. 2, Groups A, B, C, and D, Class II, Div. 2, Groups F and G, Class III (wall mount only), ATEX II 3D, EAC Ex
|
Communication | - RS 232 with Modbus RTU or ASCII via RJ-11 connector
- RS 485 with Modbus RTU or ASCII via terminal strips
- Optional: SmartLinx cards for
|