Article number

6ES7671-0RC08-0YA0

SIMATIC WINAC RTX 2010

General information

 

Firmware version

V4.6

Engineering with

 

  • в—Џ Programming package

STEP 7 V5.5 or higher / iMap V3.0 SP1; STEP 7 in TIA Portal V13 or higher

Memory

 

Type of memory

RAM

Work memory

 

  • в—Џ integrated (for program)

4 Mbyte; Adjustable; depends on Non Paged Memory Pool

  • в—Џ integrated (for data)

4 Mbyte; Adjustable; depends on Non Paged Memory Pool

Load memory

 

  • в—Џ integrated RAM, max.

8 Mbyte; Adjustable; depends on Non Paged Memory Pool

CPU processing times

 

for bit operations, typ.

0.004 µs; Typical

for fixed point arithmetic, typ.

0.003 µs; Typical

for floating point arithmetic, typ.

0.004 µs; Typical

Reference platform

Pentium 4, 2.4 GHz

CPU-blocks

 

DB

 

  • в—Џ Number, max.

65 535; Limited only by RAM set for data

  • в—Џ Size, max.

64 kbyte

FB

 

  • в—Џ Number, max.

65 536; Limited only by RAM set for code

  • в—Џ Size, max.

64 kbyte

FC

 

  • в—Џ Number, max.

65 536; Limited only by RAM set for code

  • в—Џ Size, max.

64 kbyte

OB

 

  • в—Џ Number, max.

Limited only by RAM set for code

  • в—Џ Size, max.

64 kbyte

  • в—Џ Number of free cycle OBs

1; OB 1

  • в—Џ Number of time alarm OBs

1; OB 10

  • в—Џ Number of delay alarm OBs

1; OB 20

  • в—Џ Number of cyclic interrupt OBs

9; OB 30-38

  • в—Џ Number of process alarm OBs

1; OB 40

  • в—Џ Number of ODK OBs

3; OB 52-54

  • в—Џ Number of DPV1 alarm OBs

3; OB 55-57

  • в—Џ Number of isochronous mode OBs

2; OB 61-62

  • в—Џ Number of startup OBs

2; OB 100, 102

  • в—Џ Number of asynchronous error OBs

7; OB 80, 82-85, 86, 88

  • в—Џ Number of synchronous error OBs

2; OB 121, 122

Nesting depth

 

  • в—Џ per priority class

24

  • в—Џ additional within an error OB

24

Counters, timers and their retentivity

 

S7 counter

 

  • в—Џ Number

2 048

Retentivity

 

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

2 047

  • — preset

8

Counting range

 

  • — can be set

Yes

  • — lower limit

0

  • — upper limit

999

IEC counter

 

  • в—Џ Number

Unlimited (limited only by RAM capacity)

S7 times

 

  • в—Џ Number

2 048

Retentivity

 

  • — adjustable

Yes

  • — lower limit

0

  • — upper limit

2 047

  • — preset

0

Time range

 

  • — lower limit

10 ms

  • — upper limit

9 990 s

IEC timer

 

  • в—Џ present

Yes

  • в—Џ Type

SFB

  • в—Џ Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

Retentivity without UPS and PS Extension Board

128 kbyte with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request

Retentivity with UPS

all data

Flag

 

  • в—Џ Number, max.

16 kbyte

  • в—Џ of which retentive

MB 0 to MB 16383

  • в—Џ Retentivity preset

MB 0 to MB 15

  • в—Џ Number of clock memories

8

Data blocks

 

  • в—Џ Number, max.

Limited only by available retentive memory (NVRAM, or file storage)

  • в—Џ Size, max.

64 kbyte

  • в—Џ Retentivity adjustable

Yes; via non-retain property on DB

  • в—Џ Retentivity preset

Yes

Local data

 

  • в—Џ adjustable, max.

64 kbyte

  • в—Џ preset

32 kbyte

  • в—Џ per priority class, max.

61 440 byte

Address area

 

I/O address area

 

  • в—Џ Inputs

16 kbyte

  • в—Џ Outputs

16 kbyte

of which distributed

 

  • — DP interface, inputs

16 kbyte

  • — DP interface, outputs

16 kbyte

  • — PROFINET interface, inputs

16 kbyte

  • — PROFINET interface, outputs

16 kbyte

Process image

 

  • в—Џ Inputs, adjustable

8 kbyte; 16 KB with STEP 7 V5.5 SP3 or higher

  • в—Џ Outputs, adjustable

8 kbyte; 16 KB with STEP 7 V5.5 SP3 or higher

  • в—Џ Inputs, default

512 byte

  • в—Џ Outputs, default

512 byte

Subprocess images

 

  • в—Џ Number of subprocess images, max.

15

Digital channels

 

  • в—Џ Inputs

128 000

  • в—Џ Outputs

128 000

Analog channels

 

  • в—Џ Inputs

8 000

  • в—Џ Outputs

8 000

Number of operable FMs and CPs (recommended)

 

  • в—Џ FM

FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2

  • в—Џ CP, PtP

2; CP 340, CP 341 distributed

  • в—Џ CP, LAN

Over PC CP

Submodules

 

  • в—Џ Number of submodules, max

4

  • — of which PROFIBUS, max.

4; Supported interfaces: see 1st and 2nd interface

  • — of which Industrial Ethernet, max.

1; Supported interfaces: see 3rd and 4th interface

Time of day

 

Clock

 

  • в—Џ Hardware clock (real-time)

Yes

  • в—Џ retentive and synchronizable

Yes

Operating hours counter

 

  • в—Џ Number

8

Clock synchronization

 

  • в—Џ supported

Yes

  • в—Џ to PC-CP, slave

Yes

  • в—Џ on Ethernet via NTP

Yes

1. Interface

 

Interface type

CP 5611, CP 5611-A2, CP 5612, CP 5621, CP 5622, integrated PROFIBUS interface of the SIMATIC PC

Physics

RS 485 / PROFIBUS

Isolated

Yes

Number of simultaneously operable CPs, max.

1

Power supply to interface (15 to 30 V DC), max.

does not exist

Functionality

 

  • в—Џ MPI

No

  • в—Џ PROFIBUS DP master

Yes

  • в—Џ PROFIBUS DP slave

No

DP master

 

  • в—Џ Number of connections, max.

8

  • в—Џ Transmission rate, max.

12 Mbit/s

  • в—Џ Number of DP slaves, max.

64

Services

 

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Equidistance

Yes; Only in conjunction with isochronous mode

  • — Isochronous mode

Yes

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV0

Yes

  • — DPV1

Yes

Address area

 

  • — Inputs, max.

16 kbyte

  • — Outputs, max.

16 kbyte

User data per DP slave

 

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

2. Interface

 

Interface type

CP 5613, CP 5613-A2, CP 5613-A3, CP 5603, CP 5623

Physics

RS 485 / PROFIBUS

Isolated

Yes

Number of simultaneously operable CPs, max.

4

Functionality

 

  • в—Џ MPI

No

  • в—Џ PROFIBUS DP master

Yes

  • в—Џ PROFIBUS DP slave

No

DP master

 

  • в—Џ Number of connections, max.

50

  • в—Џ Transmission rate, max.

12 Mbit/s

  • в—Џ Number of DP slaves, max.

125

Services

 

  • — PG/OP communication

Yes

  • — Routing

Yes

  • — Global data communication

No

  • — S7 basic communication

No

  • — S7 communication

Yes

  • — S7 communication, as client

Yes

  • — S7 communication, as server

Yes

  • — Equidistance

Yes; Only in conjunction with isochronous mode

  • — Isochronous mode

Yes

  • — SYNC/FREEZE

Yes

  • — Activation/deactivation of DP slaves

Yes

  • — Direct data exchange (slave-to-slave communication)

Yes

  • — DPV0

Yes

  • — DPV1

Yes

Address area

 

  • — Inputs, max.

16 kbyte

  • — Outputs, max.

16 kbyte

User data per DP slave

 

  • — Inputs, max.

244 byte

  • — Outputs, max.

244 byte

3. Interface

 

Interface type

PROFINET

Physics

Ethernet

Isolated

Yes

Number of simultaneously operable CPs, max.

1; Intel Pro/1000 (Intel 82571EB, 82573L, 82574L, 82541PI; non-shared IRQ required); Intel i210T; integrated IE interface SIMATIC PC IPC4x7C, IPC6x7C, IPC8x7C, IPC2x7D, IPC4x7D, IPC6x7D, IPC8x7D, IPC547E

automatic detection of transmission rate

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Interface types

 

  • в—Џ Number of ports

1

  • в—Џ integrated switch

No

Media redundancy

 

  • в—Џ supported

No

Functionality

 

  • в—Џ PROFINET IO Controller

Yes

  • в—Џ PROFINET IO Device

No

  • в—Џ PROFINET CBA

Yes

  • в—Џ Open IE communication

Yes

PROFINET IO Controller

 

  • в—Џ Transmission rate, max.

100 Mbit/s

Services

 

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — S7 communication

Yes

  • — Isochronous mode

No

  • — Open IE communication

Yes

  • — IRT

No

  • — Prioritized startup

Yes

  • — Number of IO devices with prioritized startup, max.

32

  • — Number of connectable IO Devices for RT, max.

128

  • — of which in line, max.

128

  • — Activation/deactivation of IO Devices

Yes

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • — IO Devices changing during operation (partner ports), supported

Yes

  • — Device replacement without swap medium

Yes

  • — Send cycles

1 ms

  • — Updating time

1 to 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)

Address area

 

  • — Inputs, max.

16 kbyte

  • — Outputs, max.

16 kbyte

  • — User data per address area, max.

2 kbyte

  • — User data consistency, max.

256 byte

PROFINET CBA

 

  • в—Џ acyclic transmission

Yes

  • в—Џ cyclic transmission

Yes

Open IE communication

 

  • в—Џ Number of connections, max.

32

  • в—Џ Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • в—Џ Keep-alive function, supported

Yes

SIMATIC communication

 

  • в—Џ Number of connections, max.

16

4. Interface

 

Interface type

PROFINET

Physics

Ethernet

Isolated

Yes

Number of simultaneously operable CPs, max.

1; CP 1616 (hardware release 8 or higher), CP 1604 (hardware release 7 or higher), integrated PROFINET interface of SIMATIC IPC and S7-mEC

automatic detection of transmission rate

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes

Interface types

 

  • в—Џ Number of ports

3

  • в—Џ integrated switch

Yes

Media redundancy

 

  • в—Џ supported

Yes

  • в—Џ Switchover time on line break, typ.

200 ms

  • в—Џ Number of stations in the ring, max.

50

Functionality

 

  • в—Џ PROFINET IO Controller

Yes

  • в—Џ PROFINET IO Device

No

  • в—Џ PROFINET CBA

Yes

  • в—Џ Open IE communication

Yes

  • в—Џ Web server

Yes

PROFINET IO Controller

 

  • в—Џ Transmission rate, max.

100 Mbit/s

Services

 

  • — PG/OP communication

Yes

  • — S7 routing

Yes

  • — S7 communication

Yes

  • — Isochronous mode

Yes

  • — Open IE communication

Yes

  • — IRT

Yes

  • — Prioritized startup

Yes

  • — Number of IO devices with prioritized startup, max.

32

  • — Number of connectable IO Devices, max.

256

  • — Of which IO devices with IRT, max.

64

  • — of which in line, max.

32

  • — Number of IO Devices with IRT and the option "high flexibility"

64

  • — of which in line, max.

32

  • — Number of connectable IO Devices for RT, max.

256

  • — of which in line, max.

256

  • — Activation/deactivation of IO Devices

Yes

  • — Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • — IO Devices changing during operation (partner ports), supported

Yes

  • — Device replacement without swap medium

Yes

  • — Send cycles

250 µs, 500 µs, 1 ms

Address area

 

  • — User data per address area, max.

2 kbyte

Open IE communication

 

  • в—Џ Local port numbers used at the system end

0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535

SIMATIC communication

 

  • в—Џ Number of connections, max.

32

Protocols

 

Open IE communication

 

  • в—Џ TCP/IP

Yes

  • — Data length for connection type 01H, max.

Not supported

  • — Data length for connection type 11H, max.

65 534 byte

  • — Data length, max.

65 534 byte

  • в—Џ ISO-on-TCP (RFC1006)

Yes

  • — Data length, max.

65 534 byte

  • в—Џ UDP

Yes

  • — Data length, max.

1 472 byte

Web server

 

  • в—Џ User-defined websites

No

  • в—Џ Number of HTTP clients

2

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes

Equidistance

Yes

Number of DP masters with isochronous mode

2

User data per isochronous slave, max.

128 byte

shortest clock pulse

2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image

Communication functions

 

PG/OP communication

Yes

Data record routing

Yes; only with CP 5611 or integrated PROFIBUS interface of the SIMATIC PC

Global data communication

 

  • в—Џ supported

No

S7 basic communication

 

  • в—Џ supported

No

S7 communication

 

  • в—Џ supported

Yes

  • в—Џ as server

Yes

  • в—Џ as client

Yes

  • в—Џ User data per job, max.

64 kbyte; when using BSEND/USEND

Web server

 

  • в—Џ supported

Yes

PROFINET CBA (at set setpoint communication load)

 

  • в—Џ Setpoint for the CPU communication load

20 %

  • в—Џ Number of remote interconnection partners

64

  • в—Џ Number of functions, master/slave

30

  • в—Џ Total of all master/slave connections

1 000

  • в—Џ Data length of all incoming connections master/slave, max.

6 800 byte

  • в—Џ Data length of all outgoing connections master/slave, max.

6 800 byte

  • в—Џ Number of device-internal and PROFIBUS interconnections

500

  • в—Џ Data length of device-internal und PROFIBUS interconnections, max.

4 000 byte

  • в—Џ Data length per connection, max.

1 400 byte

Remote interconnections with acyclic transmission

 

  • — Sampling frequency: Sampling time, min.

500 ms

  • — Number of incoming interconnections

100

  • — Number of outgoing interconnections

100

  • — Data length of all incoming interconnections, max.

2 000 byte

  • — Data length of all outgoing interconnections, max.

2 000 byte

  • — Data length per connection, max.

1 400 byte

Remote interconnections with cyclic transmission

 

  • — Transmission frequency: Transmission interval, min.

10 ms

  • — Number of incoming interconnections

200

  • — Number of outgoing interconnections

200

  • — Data length of all incoming interconnections, max.

4 800 byte

  • — Data length of all outgoing interconnections, max.

4 800 byte

  • — Data length per connection, max.

250 byte

HMI variables via PROFINET (acyclic)

 

  • — Number of stations that can log on for HMI variables (PN OPC/iMap)

3

  • — HMI variable updating

500 ms

  • — Number of HMI variables

200

  • — Data length of all HMI variables, max.

2 000 byte

PROFIBUS proxy functionality

 

  • — supported

Yes

  • — Number of linked PROFIBUS devices

16

  • — Data length per connection, max.

240 byte; Slave-dependent

Number of connections

 

  • в—Џ overall

96

  • в—Џ usable for PG communication

  • — reserved for PG communication

1

  • в—Џ usable for OP communication

  • — reserved for OP communication

1

S7 message functions

 

Number of login stations for message functions, max.

62

SCAN procedure

No

Process diagnostic messages

Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ

simultaneously active Alarm-S blocks, max.

20; of a total of 20 for all SFCs

Alarm 8-blocks

Yes

  • в—Џ Number of instances for alarm 8 and S7 communication blocks, max.

4 000

Process control messages

No

Number of archives that can log on simultaneously (SFB 37 AR_SEND)

32

Test commissioning functions

 

Status block

Yes

Single step

Yes

Number of breakpoints

20

Status/control

 

  • в—Џ Status/control variable

Yes

Forcing

 

  • в—Џ Forcing

No

Diagnostic buffer

 

  • в—Џ present

Yes

  • в—Џ Number of entries, max.

  • — adjustable

Yes

  • — preset

120

Hardware requirement

 

Hardware required

PC with color monitor, keyboard, mouse or pointing device for Windows

Processor

 

  • в—Џ Processor

Intel Celeron M, 900 MHz or compatible

  • — Multi-processor system

Yes; Dual Pentium, CoreDuo, Core2Duo or compatible

  • — Hyper-threading

Yes

Lifetime of module

 

  • в—Џ Main memory, min.

1 Gbyte; WES7: 2 GB

  • в—Џ Required memory on hard disk

100 Mbyte

Operating systems

 

pre-installed operating system

 

  • в—Џ Windows NT 4.0

No

  • в—Џ Windows 2000

No

  • в—Џ Windows Vista

No

  • в—Џ Windows XP

Yes; Professional, SP2 and SP3

  • в—Џ Windows XP Embedded

Yes; With the delivery image of the SIMATIC PC

  • — supported HAL types under Windows XP

ACPI uniprocessor PC, ACPI multiprocessor PC, MPS multiprocessor PC

  • в—Џ Windows 7

Yes; Professional, Enterprise, Ultimate (only 32 bits)

  • в—Џ Windows Embedded Standard 7

Yes; With delivery image of SIMATIC PC (only 32-bit)

Configuration

 

Configuration software

 

  • в—Џ STEP 7

Yes; V5.5 and higher, Engineering Tools (optional)

Programming

 

  • в—Џ Nesting levels

8

Programming language

 

  • — LAD

Yes

  • — FBD

Yes

  • — STL

Yes

  • — SCL

Yes

  • — CFC

Yes

  • — GRAPH

Yes

  • — HiGraph®

Yes

Software libraries

 

  • — Easy Motion Control

Yes

  • — Software redundancy

Yes; As of V1.2, only operation of WinAC RTX with WinAC RTX

Number of simultaneously active SFCs

 

  • — DPSYC_FR

20; of a total of 20 for all SFCs

  • — D_ACT_DP

20; of a total of 20 for all SFCs

  • — RD_REC

20; of a total of 20 for all SFCs

  • — WR_REC

20; of a total of 20 for all SFCs

  • — WR_PARM

20; of a total of 20 for all SFCs

  • — PARM_MOD

20; of a total of 20 for all SFCs

  • — WR_DPARM

20; of a total of 20 for all SFCs

  • — DPNRM_DG

20; of a total of 20 for all SFCs

  • — RDSYSST

20; of a total of 20 for all SFCs

Number of simultaneously active SFBs

 

  • — RDREC

20; of a total of 20 for all SFBs

  • — WRREC

20; of a total of 20 for all SFBs

Know-how protection

 

  • в—Џ User program protection/password protection

Yes

  • в—Џ Block encryption

No

Open Development interfaces

 

  • в—Џ CCX (Custom Code Extension)

Yes; WinAC ODK V4.2 or higher

  • в—Џ CMI (Controller Management Interface)

Yes; WinAC ODK V4.2 or higher

  • в—Џ SMX (Shared Memory Extension)

Yes; WinAC ODK V4.2 or higher

  • — Inputs

4 kbyte

  • — Outputs

4 kbyte

Peripherals/Options

 

Peripherals

none

  • в—Џ Printer

No

Weights

 

Weight, approx.

100 g; With packaging


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Рейтинг@Mail.ru Яндекс.Метрика