General information | |
HW functional status | 01 |
Firmware version | V3.3 |
Engineering with | |
| STEP 7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204 |
Supply voltage | |
Rated value (DC) | |
| Yes |
permissible range, lower limit (DC) | 19.2V |
permissible range, upper limit (DC) | 28.8V |
external protection for power supply lines (recommendation) | Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A |
Mains buffering | |
| 5ms |
| 1s |
Load voltage L+ | |
Digital inputs | |
| 24V |
| Yes |
Digital outputs | |
| 24V |
| No |
Input current | |
Current consumption (rated value) | 580mA |
Current consumption (in no-load operation), typ. | 110mA |
Inrush current, typ. | 5A |
It | 0.7As |
Digital inputs | |
| 80mA |
Digital outputs | |
| 50mA |
Power loss | |
Power loss, typ. | 9W |
Memory | |
Work memory | |
| 128kbyte |
| No |
| 64kbyte |
Load memory | |
| Yes |
| 8Mbyte |
| 10y |
Backup | |
| Yes; Guaranteed by MMC (maintenance-free) |
| Yes; Program and data |
CPU processing times | |
for bit operations, typ. | 0.07s |
for word operations, typ. | 0.15s |
for fixed point arithmetic, typ. | 0.2s |
for floating point arithmetic, typ. | 0.72s |
CPU-blocks | |
Number of blocks (total) | 1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB | |
| 1024; Number range: 1 to 16000 |
| 64kbyte |
FB | |
| 1024; Number range: 0 to 7999 |
| 64kbyte |
FC | |
| 1024; Number range: 0 to 7999 |
| 64kbyte |
OB | |
| see instruction list |
| 64kbyte |
| 1; OB 1 |
| 1; OB 10 |
| 2; OB 20, 21 |
| 4; OB 32, 33, 34, 35 |
| 1; OB 40 |
| 1; OB 100 |
| 4; OB 80, 82, 85, 87 |
| 2; OB 121, 122 |
Nesting depth | |
| 16 |
| 4 |
Counters, timers and their retentivity | |
S7 counter | |
| 256 |
Retentivity | |
| Yes |
| 0 |
| 255 |
| Z 0 to Z 7 |
Counting range | |
| Yes |
| 0 |
| 999 |
IEC counter | |
| Unlimited (limited only by RAM capacity) |
S7 times | |
| 256 |
Retentivity | |
| Yes |
| 0 |
| 255 |
| No retentivity |
Time range | |
| 10ms |
| 9990s |
IEC timer | |
| Yes |
| SFB |
| Unlimited (limited only by RAM capacity) |
Data areas and their retentivity | |
retentive data area in total | All, max. 64 KB |
Flag | |
| 256byte |
| Yes; MB 0 to MB 255 |
| MB 0 to MB 15 |
| 8; 1 memory byte |
Data blocks | |
| Yes; via non-retain property on DB |
| Yes |
Local data | |
| 32kbyte; Max. 2048 bytes per block |
Address area | |
I/O address area | |
| 1024byte |
| 1024byte |
of which distributed | |
| none |
| none |
Process image | |
| 1024byte |
| 1024byte |
| 1024byte |
| 1024byte |
| 128byte |
| 128byte |
Default addresses of the integrated channels | |
| 124.0 to 125.7 |
| 124.0 to 125.7 |
Digital channels | |
| 1008 |
| 1008 |
| 1008 |
| 1008 |
Analog channels | |
| 248 |
| 248 |
| 248 |
| 248 |
Hardware configuration | |
Number of expansion units, max. | 3 |
Number of DP masters | |
| none |
| 4 |
Number of operable FMs and CPs (recommended) | |
| 8 |
| 8 |
| 6 |
Rack | |
| 4 |
| 8; In rack 3 max. 7 |
Time of day | |
Clock | |
| Yes |
| Yes |
| 6wk; At 40 C ambient temperature |
| 10s; Typ.: 2 s |
| Clock continues running after POWER OFF |
| Clock continues to run with the time at which the power failure occurred |
Operating hours counter | |
| 1 |
| 0 |
| 0 to 2^31 hours (when using SFC 101) |
| 1 hour |
| Yes; Must be restarted at each restart |
Clock synchronization | |
| Yes |
| Yes |
| Yes |
| Yes |
| No |
Digital inputs | |
Number of digital inputs | 16 |
| 12 |
integrated channels (DI) | 16 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
horizontal installation | |
| 16 |
| 8 |
vertical installation | |
| 8 |
Input voltage | |
| 24V |
| -3 to +5V |
| +15 to +30V |
Input current | |
| 8mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
| Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.) |
| 3ms |
for counter/technological functions | |
| 16s; Minimum pulse width/minimum pause between pulses at maximum counting frequency |
Cable length | |
| 1000m; 100 m for technological functions |
| 600m; For technological functions: No |
for technological functions | |
| 100m; at maximum count frequency |
| not allowed |
Digital outputs | |
Number of digital outputs | 16 |
| 4; Notice: You cannot connect the fast outputs of your CPU in parallel |
integrated channels (DO) | 16 |
Short-circuit protection | Yes; Clocked electronically |
| 1A |
Limitation of inductive shutdown voltage to | L+ (-48 V) |
Controlling a digital input | Yes |
Switching capacity of the outputs | |
| 5W |
Load resistance range | |
| 48Ω |
| 4kΩ |
Output voltage | |
| L+ (-0.8 V) |
Output current | |
| 500mA |
| 5mA |
| 0.6A |
| 5mA |
| 0.5mA |
Parallel switching of two outputs | |
| No |
| Yes |
Switching frequency | |
| 100Hz |
| 0.5Hz |
| 100Hz |
| 2.5kHz |
horizontal installation | |
| 3A |
| 2A |
vertical installation | |
| 2A |
Cable length | |
| 1000m |
| 600m |
Analog inputs | |
Number of analog inputs | 0 |
integrated channels (AI) | 0 |
Analog outputs | |
Number of analog outputs | 0 |
integrated channels (AO) | 0 |
Connectable encoders | |
| Yes |
| 1.5mA |
Interfaces | |
Number of industrial Ethernet interfaces | 0 |
Number of PROFINET interfaces | 0 |
Number of RS 485 interfaces | 1; MPI |
Number of RS 422 interfaces | 1; RS 422/485 combined |
Point-to-point | |
| 1200m |
Integrated protocol driver | |
| Yes |
| Yes |
| No |
Transmission rate, RS 422/485 | |
| 19.2kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex |
| 19.2kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex |
1. Interface | |
Interface type | Integrated RS 485 interface |
Physics | RS 485 |
Isolated | No |
Power supply to interface (15 to 30 V DC), max. | 200mA |
Functionality | |
| Yes |
| No |
| No |
| No |
MPI | |
| 187.5kbit/s |
Services | |
| Yes |
| No |
| Yes |
| Yes |
| Yes; Only server, configured on one side |
| No; but via CP and loadable FB |
| Yes |
2. Interface | |
Interface type | Integrated RS 422/ 485 interface |
Physics | RS 422/RS 485 (X.27) |
Isolated | Yes |
Power supply to interface (15 to 30 V DC), max. | No |
Functionality | |
| No |
| No |
| No |
| No |
| No |
| No |
Point-to-point connection | |
| 19.2kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex |
| Yes |
| Yes; Message on break - identification |
Communication functions | |
PG/OP communication | Yes |
Data record routing | No |
Global data communication | |
| Yes |
| 8 |
| 8 |
| 8 |
| 8 |
| 22byte |
| 22byte |
S7 basic communication | |
| Yes; Server |
| 76byte |
| 76byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication | |
| Yes |
| Yes |
| Yes; Via CP and loadable FB |
| 180byte; With PUT/GET |
| 240byte; as server |
S5 compatible communication | |
| Yes; via CP and loadable FC |
Number of connections | |
| 8 |
| 7 |
| 1 |
| 1 |
| 7 |
| 7 |
| 1 |
| 1 |
| 7 |
| 4 |
| 0 |
| 0 |
| 4 |
S7 message functions | |
Number of login stations for message functions, max. | 8; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes |
simultaneously active Alarm-S blocks, max. | 300 |
Test commissioning functions | |
Status block | Yes; Up to 2 simultaneously |
Single step | Yes |
Number of breakpoints | 4 |
Status/control | |
| Yes |
| Inputs, outputs, memory bits, DB, times, counters |
| 30 |
| 30 |
| 14 |
Forcing | |
| Yes |
| Inputs, outputs |
| 10 |
Diagnostic buffer | |
| Yes |
| 500 |
| No |
| 100; Only the last 100 entries are retained |
| 499 |
| Yes; From 10 to 499 |
| 10 |
Service data | |
| Yes |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
| Yes |
| Yes |
Integrated Functions | |
Number of counters | 3; See "Technological Functions" manual |
Counting frequency (counter) max. | 30kHz |
Frequency measurement | Yes |
Number of frequency meters | 3; up to 30 kHz (see "Technological Functions" manual) |
controlled positioning | No |
integrated function blocks (closed-loop control) | Yes; PID controller (see "Technological Functions" manual) |
PID controller | Yes |
Number of pulse outputs | 3; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual) |
Limit frequency (pulse) | 2.5kHz |
Potential separation | |
Potential separation digital inputs | |
| Yes |
| No |
| Yes |
Potential separation digital outputs | |
| Yes |
| Yes |
| 8 |
| Yes |
Isolation | |
Isolation tested with | 600 V DC |
Ambient conditions | |
Ambient temperature during operation | |
| 0C |
| 60C |
Configuration | |
Configuration software | |
| Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
| No |
Programming | |
| see instruction list |
| 8 |
| see instruction list |
| see instruction list |
Programming language | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Know-how protection | |
| Yes |
| Yes; With S7 block Privacy |
Dimensions | |
Width | 80mm |
Height | 125mm |
Depth | 130mm |
Weights | |
Weight, approx. | 500g |