Mode of operation
Measuring principle
Ultrasonic transducer
Input
Measuring range
0.3 ... 8 m (1 ... 26 ft), dependent on application
Output
Frequency
44 kHz
Beam angle
10°
Accuracy
Temperature error
Compensated by integral temperature sensor
Rated operating conditions
Vessel pressure
Normal atmospheric pressure
Ambient Conditions
-20 ... +65 °C (-4 ... +149 ° F)
Design
Weight (approximate shipping weight of sensor with standard cable length)
1.2 kg (2.6 lb)
Material (enclosure)
PVDF copolymer enclosure and CSM face
Process connection
1" NPT [(Taper), ANSI/ASME B1.20.1] or R 1" [(BSPT), EN 10226]
Degree of protection
IP65/IP68
Cable connection
2-core shielded/twisted, 0.5 mm2 (20 AWG), PVC sheath
Cable (max. length)
Options
Flange version
Factory flange with PTFE face for ASME, EN or JIS configuration
Submergence shield
For applications with flooding possible
Certificates and approvals
CE, RCM, KCC
CSA Class I, Div. 2, Groups A, B, C, D, Class II, Div. 1 Groups E, F, G
FM Class I, Zone 1, AEx m IIC, T6 Class II, III, Div. 1, Groups E, F, G T6
ATEX II 2GD / IECEx / INMETRO Ex mb IIC T6 Gb, Ex tb IIIC T85 °C Db