Contact blocks and lampholdersType | 3SB34 00, 3SB34 20 | 3SB34 03, 3SB34 23 | 3SB34 11 | 3SB14 00-0J |
|---|
Standards | IEC 60947-5-1, IEC 60947-5-5, EN 60947-5-1, EN 60947-5-5 | Connection type | Screw terminals | Spring-loaded terminals | Solder pins | Screw terminals | Rated insulation voltage Ui | 400 V 3SB34 .0-1: 250 V | 400 V | 250 V 3SB34 11-1: 60 V | 400 V | For degree of pollution according to IEC 60947-1 | Class 3 | Class 3 | Class 3 | Class 3 | Rated impulse withstand voltage Uimp | 4 kV | Continuous thermal current Ith | 10 A | Rated operational currents Ie at rated operational voltage Ue | | - Alternating current 50/60 Hz, AC-12
| | | 10 A | 10 A | 10 A | 10 A | | 10 A | 10 A | 10 A | 10 A | | 10 A | 10 A | 10 A | 10 A | | 10 A | 10 A | 10 A | 10 A | | 10 A | 10 A | – | 10 A | - Alternating current 50/60 Hz, AC-15
| | | 6 A | 6 A | 4 A | 6 A | | 6 A | 6 A | 4 A | 6 A | | 6 A | 6 A | 4 A | 6 A | | 6 A | 6 A | 4 A | 6 A | | 3 A | 3 A | – | 3 A | | | | 10 A | 10 A | 10 A | 10 A | | 5 A | 5 A | 5 A | – | | 2.5 A | 2.5 A | 2.5 A | 2 A | | 1 A | 1 A | 1 A | 0.5 A | | | | 3 A | 3 A | 3 A | 5 A | | 1.5 A | 1.5 A | 1.5 A | – | | 0.7 A | 0.7 A | 0.7 A | 0.5 A | | 0.3 A | 0.3 A | 0.3 A | 0.2 A | Contact stability | | - Test voltage/test current
| 5 V / 1 mA | Lampholders | BA 9s | BA 9s | Wedge bases | – | | Incandescent lamps, glow lamps and LED lamps | Incandescent lamps, glow lamps and LED lamps | Glow lamps and LED lamps | – | | 230 V1) | 230 V1) | 60 V | – | Short-circuit protection (weld-free according to IEC 60947-5-1) | | - DIAZED fuse links,
utilization category gG according to IEC 60269-3-1, DIN VDE 0636-301
| Dz 10 A | - DIAZED fuse links,
quick according to DIN VDE 0635
| Dz 16 A | - Miniature circuit breaker with C characteristic according to IEC 60 898 (VDE 0641)
| 10 A | Mechanical endurance | 10 × 106 operating cycles | Electrical endurance | | - For utilization category AC-15 with 3RT10 15 to 3RT10 26 contactors
| 10 × 106 operating cycles | - With utilization category DC-12, DC-13
| With direct current the contact endurance depends not only on the breaking current but also on the voltage, the circuit inductance and the speed of switching. | Switching frequency | 1000 operating cycles/h | Degree of protection according to IEC 60529 | | | IP20 | | IP40 | Touch protection according to IEC 61140 and BGV A2 | Touch protection | Touch protection | – | Touch protection | Conductor cross-sections2) | | - Finely stranded, without end sleeves
| – | 2 × (0,25 .... 1.5) mm2 | – | – | - Finely stranded, with end sleeves to DIN 46228
| 2 × (0.5 .... 1.5) mm2 | 2 × (0,25 .... 0.75) mm2 | – | 2 × (0.5 .... 1.5) mm2 | | 2 × (1 .... 1.5) mm2 | 2 × (0,25 .... 1.5) mm2 | – | 2 × (1 .... 2.5) mm2 | - Solid with end sleeves to DIN 46228
| 2 × (0.5 .... 0.75) mm2 | – | – | 2 × (0.5 .... 0.75) mm2 | - AWG cables, solid or stranded
| 2 × AWG 18 ... 14 | 2 × AWG 24 ... 16 | – | – | Tightening torque, terminal screw | 0.8 Nm | – | – | 0.8 Nm | Solder pins | – | – | 0.8 × 0.8 mm2 | – |
1) Incandescent lamp max. 130 V; use lampholder with integrated voltage reducer for 230 V AC. 2) For standard screw driver size 2 and Pozidrive 2. Data according to UL and CSAType | 3SB34 00, 3SB34 20 | 3SB34 03, 3SB34 23 | 3SB34 11 | 3SB14 00-0J |
|---|
Standards | UL and CSA | Rated operational voltage | 300 V AC | 300 V AC | 300 V AC | 300 V AC | Conventional free air thermal current (uninterrupted current) | 10 A | 10 A | 10 A | 10 A | Switching capacity | A 300, R 300, A 600 same polarity | Rated voltage (lamps) | | | 125 V AC | 125 V AC | – | – | | 60 V AC | 60 V AC | 60 V AC | – | - Lampholders with integrated LED
| 24 V AC/DC, 110 V AC, 230 V AC | 24 V AC/DC, 110 V AC, 230 V AC | – | – | Rated power (lamps) | 2.5 W | 2.5 W | 1 W | – |
Actuators and indicatorsType | 3SB30, 3SB32 | 3SB31, 3SB33 | 3SB35, 3SB36 |
|---|
Enclosure material | Plastic | Plastic | Metal | Design | Round | Square | Round | Terminal designation according to EN 50013 | Identification number on the holder, function digit on the contact block | Device identification | With snap-on label | Tightening torques | | | max. 1 Nm | | 0.8 Nm | Mechanical endurance | | | 10 × 106 operating cycles | | 3 × 106 operating cycles | - Actuators, rotary or maintained contact
| 3 × 105 operating cycles | - Key-operated switch with key monitoring
| 1 × 105 operating cycles | Switching frequency | 1000 operating cycles/h | Climatic withstand capabilityaccording to EN ISO 6270-2 | Climate-proof KTW 24; for operation in marine applications | Ambient temperature | | - During operation, non-illuminated and with LED
| –25 ... +70 °C | - During operation, with incandescent lamp
| –25 ... +60 °C | - During storage, transport
| –40 ... +80 °C | Degree of protection according to IEC 60529 | | - Actuators and indicators, standard
| IP66 | IP65 | IP67 and NEMA type 4 | | IP67 | IP67 | – | - Key-operated switch with key monitoring
| IP54 | – | – | | IP65 | – | – | Protective measures | | Plastic version | Protective measures are met automatically when the actuators and lens assemblies are mounted on metal front plates and enclosures. When mounted in insulated enclosures, the "total insulation" safety requirements are met. | Grounding is necessary for operation with protective extra-low voltage (PELV). | Shock resistance according to IEC 60068-2-27 for half-sine shock type, 11 ms shock duration | | - Devices without incandescent lamp
| ≤ 50 g | - Devices with incandescent lamp
| ≤ 30 g | Vibration resistance according to IEC 60068-2-6 | | - Acceleration at frequency 20 ... 200 Hz
| 5 g |
EnclosuresType | 3SB38 0.-0, 3SB38 0.-1 | – | 3SB38 0.-2, 3SB38 0.-3 |
|---|
Enclosure material | Plastic | | Metal | Design, actuators and indicators | Round | | Round | Degree of protection according to IEC 60529 | IP65 | | IP67 and NEMA type 4 |
|
|