Siemens
01 2018
(4872) 700-366
skenergo@mail.ru
 01 2017  

Article number

6ES7647-8B...-....

6AG4022-0AA21-0BA1

6AG4141-.....-....

6AG4131-2....-....

6AG4132-2....-....

SIMATIC IPC227E (NANOBOX PC)

SIMATIC IPC327E

SIMATIC IPC427E (MicroBOX PC)

SIMATIC IPC627D (BOX PC)

SIMATIC IPC827D (BOX PC)

Installation type/mounting

Mounting

DIN rail, wall mounting, portrait mounting

Standard mounting rail, wall mounting (horizontal and vertical)

DIN rail, wall mounting, portrait mounting

Wall mounting, portrait mounting

Wall mounting, portrait mounting

Design

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Box PC, built-in unit

Supply voltage

Type of supply voltage

24 V DC

24 V DC

24 V DC

100/240 V AC (autorange); 24 V DC

100/240 V AC (autorange); 24 V DC

Line frequency

  • Rated value 50 Hz

Yes

Yes

  • Rated value 60 Hz

Yes

Yes

Mains buffering

  • Mains/voltage failure stored energy time

20ms

10ms

20ms

20ms

Processor

Processor type

Intel Celeron N2807 / N2930

Intel Celeron N3160

Celeron G3902 (2C/2T, 1.6 GHz, 2 MB Cache); Core i3-6102E (2C/4T, 1.9 GHz, 3 MB Cache); Core i5-6442EQ (4C/4T, 1.9 (2.7) GHz, 6 MB Cache, iAMT); Xeon E3-1505L v5 (4C/8T, 2.0 (2.8) GHz, 8 MB Cache, iAMT)

Celeron G1820TE (2C/2T, 2.2 GHz, 2 MB Cache); Core i3-4330TE (2C/4T, 2.4 GHz, 4 MB Cache); Xeon E3-1268L v3 (4C/8T, 2.3 (3.3) GHz, 8 MB Cache, AMT)

Celeron G1820TE (2C/2T, 2.2 GHz, 2 MB Cache); Core i3-4330TE (2C/4T, 2.4 GHz, 4 MB Cache); Xeon E3-1268L v3 (4C/8T, 2.3 (3.3) GHz, 8 MB Cache, AMT)

Chipset

Intel DH82C226 PCH

Intel DH82C226 PCH

Graphic

Graphics controller

Intel HD graphics controller

Intel HD graphics controller P4600 GT2 (Xeon, Core i3); Intel HD graphics controller (Celeron)

Intel HD graphics controller P4600 GT2 (Xeon, Core i3); Intel HD graphics controller (Celeron)

Drives

Optical drives

DVDRRW combi-drive, optional

DVDRRW combi-drive, optional

Hard disk

2.5" SATA ≥ 320 GB

500 GB HDD

2.5" SATA ≥ 320 GB

3.5" SATA ≥ 250 GB, optional ≥ 500 GB; RAID1 2x 2.5" SATA ≥ 320 GB; all internal drives are vibration-damped

3.5" SATA ≥ 250 GB, optional ≥ 500 GB; RAID1 2x 2.5" SATA ≥ 320 GB; all internal drives are vibration-damped

SSD

Yes; ≥ 80 GB optional

Yes; 1x 80 GB, 1x 240 GB SSD, 1x 480 GB SSD

Yes; ≥ 240 GB optional

Yes; ≥ 240 GB optional

Memory

Type of memory

DDR3L

DDR3L

DDR4 SO-DIMM

DDR3 1600 DIMM

DDR3 1600 DIMM

Main memory

2 / 4 / 8 GB

4 GB (pre-installed)

4 GB to 16 GB, ECC optional

2 / 4 / 8 / 16 GB; ECC optional

2 / 4 / 8 / 16 GB; ECC optional

Capacity of main memory, max.

8Gbyte

8Gbyte

16Gbyte

16Gbyte

16Gbyte

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max.

512kbyte; 128 KB can be stored in the buffer time; optional

512kbyte; 128 KB can be stored in the buffer time; optional

2Mbyte; 128 KB can be stored in the buffer time; optional

2Mbyte; 128 KB can be stored in the buffer time; optional

Hardware configuration

Slots

  • free slots

1x PCIe x1 (optional)

1x mPCIe (half-size), 1x mSATA (full-size)

2x PCIe; optional: 1x PCIe (x4); 2x PCIe (x1, x4), with card retainer

2x PCI; optional: 1x PCI & 1x PCIe (x16); 2x PCIe (x4, x16); with card retainer

3x PCI, 1x PCIe (x4), 1x PCIe (x16); with card retainer

  • Number of PCI slots

2; Optional

3

  • Number of PCI slots

1; Optional

2; Optional

2; Optional

2

  • Number of compact flash slots

1; CFast

1; CFast

Interfaces

PROFIBUS/MPI

Optionally onboard, isolated, max. 12 Mbit/s, compatible with CP 5622

Optionally onboard, isolated, max. 12 Mbit/s, compatible with CP 5622

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

3; Ethernet (2x RJ45, optional 3x RJ45)

Number of PROFINET interfaces

3; Optional

3; Optional

USB port

1x USB 3.0 / 3x USB 2.0

4x USB 2.0, 2x USB 3.0 (high current)

4x USB 3.0

4x USB 3.0

4x USB 3.0

Connection for keyboard/mouse

USB / USB

USB / USB

USB / USB

USB / USB

serial interface

Without / 2x COM (RS 232 / 422 / 485), selectable in the BIOS

Without / 2x COM (RS 232 / RS 485 / RS 422; switchable)

1x COM1 (RS 232), optional: 1x COM2 (RS 232)

1x COM1 (RS 232), optional: 1x COM2 (RS 232)

parallel interface

optional LPT1

optional LPT1

Video interfaces

  • Graphics interface

1x DisplayPort

1x DisplayPort, 1x VGA

2x DisplayPort

1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional)

1x DisplayPort and 1x DVI-I; 1x VGA via adapter cable (optional)

Industrial Ethernet

  • Industrial Ethernet interface

Onboard, 2x 10 / 100 / 1000 Mbit, RJ45

2 x Ethernet (RJ45)

3x Ethernet (RJ45)

Onboard, 2x 10 / 100 / 1000 Mbit, RJ45

Onboard, 2x 10 / 100 / 1000 Mbit, RJ45

  • 100 Mbps

Yes

Yes

Yes

Yes

Yes

  • 1000 Mbps

Yes

Yes

Yes

Yes

Yes

Protocols

Protocols (Ethernet)

  • TCP/IP

Yes

Interrupts/diagnostics/status information

Bus diagnostics

Yes

Yes

Yes

Integrated Functions

Monitoring functions

  • Temperature monitoring

Yes

Yes

Yes

Yes

Yes

  • Watchdog

Yes

Yes

Yes

Yes

Yes

  • Status LEDs

Yes

POWER, HDD

Yes

Yes

Yes

  • Fan

No

No

No

Yes

Yes

  • Monitoring function via network

Optional

Optional

Optional

Optional

EMC

Interference immunity against discharge of static electricity

  • Interference immunity against discharge of static electricity

6 kV contact discharge acc. to IEC 61000-4-2; 8 kV air discharge acc. to IEC 61000-4-2

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

6 kV contact discharge acc. to IEC 61000-4-2; 8 kV air discharge acc. to IEC 61000-4-2

6 kV contact discharge acc. to IEC 61000-4-2; 8 kV air discharge acc. to IEC 61000-4-2

6 kV contact discharge acc. to IEC 61000-4-2; 8 kV air discharge acc. to IEC 61000-4-2

  • Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

  • Test voltage at air discharge

8kV

  • Test voltage at contact discharge

6kV

Interference immunity against high-frequency electromagnetic fields

  • Interference immunity against high frequency radiation

10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6

10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6

10 V/m for 80 - 1000 MHz and 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 10 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6

Interference immunity to cable-borne interference

  • Interference immunity on supply cables

2 kV acc. to IEC 61000-4-4, burst; 1 kV acc. to IEC 61000-4-5, surge symmetric; 2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

2 kV acc. to IEC 61000-4-4, burst; 1 kV acc. to IEC 61000-4-5, surge symmetric; 2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-4, burst; 1 kV acc. to IEC 61000-4-5, surge symmetric; 2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-4, burst; 1 kV acc. to IEC 61000-4-5, surge symmetric; 2 kV acc. to IEC 61000-4-5, surge asymmetric

  • Interference immunity on signal cables >30m

2 kV acc. to IEC 61000-4-5, surge, length > 30 m

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

2 kV acc. to IEC 61000-4-5, surge, length > 30 m

2 kV acc. to IEC 61000-4-5, surge, length > 30 m

2 kV acc. to IEC 61000-4-5, surge, length > 30 m

  • Interference immunity on signal cables < 30m

1 kV acc. to IEC 61000-4-4; burst; length < 3 m; 2 kV acc. to IEC 61000-4-4; burst; length > 3 m

1 kV acc. to IEC 61000-4-4, Burst

1 kV acc. to IEC 61000-4-4; burst; length < 3 m; 2 kV acc. to IEC 61000-4-4; burst; length > 3 m

1 kV acc. to IEC 61000-4-4; burst; length < 3 m; 2 kV acc. to IEC 61000-4-4; burst; length > 3 m

1 kV acc. to IEC 61000-4-4; burst; length < 3 m; 2 kV acc. to IEC 61000-4-4; burst; length > 3 m

Interference immunity against voltage surge

  • asymmetric interference

2 kV acc. to IEC 61000-4-5, surge asymmetric

1 kV according to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

  • symmetric interference

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

Interference immunity to magnetic fields

  • Interference immunity to magnetic fields at 50 Hz

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

Emission of conducted and non-conducted interference

  • Interference emission via line/AC current cables

EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A

EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A

EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A

EN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A

Degree and class of protection

IP (at the front)

IP40

IP20

IP20

IP20

IP (rear)

IP40

IP20

IP20

IP20

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

Yes

UL approval

Yes

Yes

Yes

Yes

Yes

  • UL 508

Yes

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Yes

Yes

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

FCC

Yes

Yes

Yes

Yes

Yes

EMC

CE, EN 61000-6-4:2007, EN 61000-6-2:2005

CE, EN 55022A, EN 61000-6-4, EN 61000-6-2

CE, EN 61000-6-3:2007 +A1:2011, EN 61000-6-2:2005

CE, EN 61000-6-3:2007 +A1:2011, EN 61000-6-2:2005

Dust protection

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Marine approval

  • Germanischer Lloyd (GL)

Yes

Yes

Yes

  • American Bureau of Shipping (ABS)

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (Class NK)

Yes

Yes

Yes

Ambient conditions

Ambient temperature during operation

  • Ambient temperature during operation

0 C up to 60 C

0 to +40 C

0 C to +55 C

+5 C up to 55 C

+5 C up to 55 C

  • min.

0C

0C

0C

5C

5C

  • max.

60C

40C

55C

55C

55C

Ambient temperature during storage/transportation

  • min.

-20C

-20C

-40C

-20C

-20C

  • max.

60C

60C

70C

60C

60C

Relative humidity

  • Relative humidity

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5% to 80% at 25 C (no condensation), Storage: 5% to 95% at 25 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5% to 80% at 25 C (no condensation), Storage: 5% to 95% at 25 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5% to 80% at 25 C (no condensation), Storage: 5% to 95% at 25 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5% to 80% at 25 C (no condensation), Storage: 5% to 95% at 25 C (no condensation)

Vibrations

  • Vibration resistance during operation acc. to IEC 60068-2-6

Tested to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm, 58 Hz to 200 Hz: 9.8 m/s (1 g)

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

Tested to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm, 58 Hz to 200 Hz: 9.8 m/s (1 g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s (1g)

Tested according to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm; 58 Hz to 500 Hz 9.8 m/s (1g)

Shock testing

  • Shock load during operation

Tested according to IEC 60068-2-27: 150 m/s, 11 ms

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

Tested to DIN IEC 60068-2-29: 50 m/s (5 g), 30 ms, 100 shocks

Tested to DIN IEC 60068-2-29: 50 m/s (5 g), 30 ms, 100 shocks

Tested to DIN IEC 60068-2-29: 50 m/s (5 g), 30 ms, 100 shocks

Operating systems

Operating system

Windows 7 Ultimate 32-bit / 64-bit, MUI; Windows Embedded Standard 7 E/P, 32-bit / 64-bit

Windows 7 Ultimate (Multi-Language) 64-bit, Windows Embedded Standard 7 E/P 32-bit / 64-bit, Windows 10

Windows 7 Ultimate 32-bit/64-bit, MUI; Windows 10 IoT Enterprise LTSB 2015, 64-bit, MUI; Windows Embedded Standard 7 P, 32-bit, MUI

Windows 7 Ultimate 32-bit/64-bit, MUI; Windows 10 IoT Enterprise LTSB 2015, 64-bit, MUI; Windows Embedded Standard 7 P, 32-bit, MUI

pre-installed operating system

Yes

Yes

Yes

Yes

without operating system

Yes

Yes

Yes

Yes

Yes

pre-installed operating system

  • Windows 7

Yes; Ultimate 32 bits or 64 bits

Yes; Ultimate 32 bits or 64 bits

Yes; Ultimate 32 bits or 64 bits

Yes; Ultimate 32 bits or 64 bits

  • Windows 10 IoT Enterprise

Yes; Windows 10 IoT Enterprise LTSB 2016 (64-bit) MUI

Yes; Windows 10 IoT Enterprise LTSB 2016 (64-bit) MUI

Yes; LTSB 2015, 64-bit, MUI

Yes; LTSB 2015, 64-bit, MUI

Software

SIMATIC Software

Optional package with SIMATIC WinCC or WinAC RTX

Optionally with pre-installed SIMATIC WinCC RT Advanced / Software Controller CPU 1500S software bundle

Optional package with SIMATIC WinCC or WinAC RTX

Optional package with SIMATIC WinCC or WinAC RTX

Dimensions

Width

191mm

254mm

262mm

312mm

312mm

Height

100mm

140mm

139.7mm

81mm; with DVD drive: 105 mm

155mm; With DVD drive: 179 mm

Depth

60mm

75mm

55.5mm

301mm; incl. mounting rail

301mm; incl. mounting rail

Other

Warranty period

36mo; Warranty period



















  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.