Article number

6ES7455-0VS00-0AE0

6ES7455-1VS00-0AE0

SIMATIC S7-400, CONTROL MODULE

SIMATIC S7-400, CONTROL MODULE

Supply voltage

Load voltage L+

  • Rated value (DC)

24V

24V

  • permissible range, lower limit (DC)

20.4V

20.4V

  • permissible range, upper limit (DC)

28.8V

28.8V

Input current

from load voltage L+ (without load), max.

440mA; typ. 370 mA

400mA; typ. 330 mA

Power loss

Power loss, typ.

12W

10.7W

Digital inputs

Number of digital inputs

16

16

Input characteristic curve in accordance with IEC 61131, type 2

Yes

Yes

Input voltage

  • Rated value (DC)

24V

24V

  • for signal "0"

-3 to +5V

-3 to +5V

  • for signal "1"

13 to 30V

13 to 30V

Input current

  • for signal "1", typ.

7mA

7mA

Cable length

  • shielded, max.

1000m

1000m

  • unshielded, max.

600m

600m

Digital outputs

Number of digital outputs

32

Short-circuit protection

Yes; Electronic

Limitation of inductive shutdown voltage to

L+ (-1.5 V)

Controlling a digital input

Yes

Switching capacity of the outputs

  • on lamp load, max.

5W

Load resistance range

  • lower limit

240Ω

  • upper limit

4kΩ

Output voltage

  • for signal "1", min.

L+ (-2.5 V)

Output current

  • for signal "1" rated value

0.1A

  • for signal "1" permissible range for 0 to 60 C, min.

5mA

  • for signal "1" permissible range for 0 to 60 C, max.

150mA

  • for signal "0" residual current, max.

0.5mA

Parallel switching of two outputs

  • for logic links

Yes

Switching frequency

  • with resistive load, max.

100Hz

  • with inductive load, max.

0.5Hz

  • on lamp load, max.

100Hz

Cable length

  • shielded, max.

1000m

  • unshielded, max.

600m

Analog inputs

Number of analog inputs

16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection

16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection

permissible input voltage for voltage input (destruction limit), max.

20V

20V

permissible input current for current input (destruction limit), max.

40mA

40mA

Input ranges

  • Voltage

Yes

Yes

  • Current

Yes

Yes

  • Thermocouple

Yes

Yes

  • Resistance thermometer

Yes

Yes

Input ranges (rated values), voltages

  • 0 to +10 V

Yes

Yes

  • Input resistance (0 to 10 V)

100kΩ

100kΩ

  • -1.75 V to +11.75 V

Yes

Yes

  • Input resistance (-1.75 V to +11.75 V)

100kΩ

100kΩ

  • -80 mV to +80 mV

Yes

Yes

  • Input resistance (-80 mV to +80 mV)

10MΩ

10MΩ

Input ranges (rated values), currents

  • 0 to 20 mA

Yes

Yes

  • Input resistance (0 to 20 mA)

50Ω

50Ω

  • 0 to 23.5 mA

Yes

Yes

  • Input resistance (0 to 23.5 mA)

50Ω

50Ω

  • -3.5 mA to +23.5 mA

Yes

Yes

  • Input resistance (-3.5 mA to +23.5 mA)

50Ω

50Ω

  • 4 mA to 20 mA

Yes

Yes

  • Input resistance (4 mA to 20 mA)

50Ω

50Ω

Input ranges (rated values), thermocouples

  • Type B

Yes

Yes

  • Input resistance (Type B)

10MΩ

10MΩ

  • Type J

Yes

Yes

  • Input resistance (type J)

10MΩ

10MΩ

  • Type K

Yes

Yes

  • Input resistance (Type K)

10MΩ

10MΩ

  • Type R

Yes

Yes

  • Input resistance (Type R)

10MΩ

10MΩ

  • Type S

Yes

Yes

  • Input resistance (Type S)

10MΩ

10MΩ

Input ranges (rated values), resistance thermometer

  • Pt 100

Yes

Yes

  • Input resistance (Pt 100)

10MΩ

10MΩ

Thermocouple (TC)

Temperature compensation

  • internal temperature compensation

Yes; Parameterizable

Yes; Parameterizable

  • external temperature compensation with Pt100

Yes; Parameterizable

Yes; Parameterizable

Characteristic linearization

  • parameterizable

Yes

Yes

  • for thermocouples

Type B, J, K, R, S

Type B, J, K, R, S

  • for resistance thermometer

Pt100 (standard)

Pt100 (standard)

Cable length

  • shielded, max.

200m; 50 m at 80 mV and thermocouples

200m; 50 m at 80 mV and thermocouples

Analog outputs

Number of analog outputs

16

Voltage output, short-circuit protection

Yes

Voltage output, short-circuit current, max.

25mA

Current output, no-load voltage, max.

18V

Output ranges, voltage

  • 0 to 10 V

Yes

  • -10 V to +10 V

Yes

Output ranges, current

  • 0 to 20 mA

Yes

  • -20 mA to +20 mA

Yes

  • 4 mA to 20 mA

Yes

Connection of actuators

  • for voltage output two-wire connection

Yes

  • for current output two-wire connection

Yes

Load impedance (in rated range of output)

  • with voltage outputs, min.

1kΩ

  • with voltage outputs, capacitive load, max.

1F

  • with current outputs, max.

500Ω

  • with current outputs, inductive load, max.

1mH

Cable length

  • shielded, max.

200m; 50 m at 80 mV and thermocouples

Analog value generation for the inputs

Measurement principle

integrating

integrating

Integration and conversion time/resolution per channel

  • Resolution with overrange (bit including sign), max.

14bit; 12 bit or 14 bit, parameterizable

14bit; 12 bit or 14 bit, parameterizable

  • Conversion time (per channel)

16.67ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 Hz and 60 Hz

16.67ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 Hz and 60 Hz

Analog value generation for the outputs

Settling time

  • for resistive load

0.1ms

  • for capacitive load

3.3ms

  • for inductive load

0.5ms

Encoder

Connection of signal encoders

  • for voltage measurement

Yes

Yes

  • for current measurement as 4-wire transducer

Yes

Yes

Connectable encoders

  • 2-wire sensor

Yes

Yes

  • permissible quiescent current (2-wire sensor), max.

1.5mA

1.5mA

Errors/accuracies

Linearity error (relative to input range), (+/-)

0.05%

0.05%

Temperature error (relative to input range), (+/-)

0.005%/K

0.005%/K

Linearity error (relative to output range), (+/-)

0.05%

Temperature error (relative to output range), (+/-)

0.02%/K

Operational error limit in overall temperature range

  • Voltage, relative to input range, (+/-)

0.6 to 1%

0.6 to 1%

  • Current, relative to input range, (+/-)

0.6 to 1%

0.6 to 1%

  • Resistance thermometer, relative to input range, (+/-)

0.6 to 1%

0.6 to 1%

  • Voltage, relative to output range, (+/-)

0.5%

  • Current, relative to output range, (+/-)

0.6%

Basic error limit (operational limit at 25 C)

  • Voltage, relative to input range, (+/-)

0.4 to 0.6 %

0.4 to 0.6 %

  • Current, relative to input range, (+/-)

0.4 to 0.6 %

0.4 to 0.6 %

  • Resistance thermometer, relative to input range, (+/-)

0.4 to 0.6 %

0.4 to 0.6 %

  • Voltage, relative to output range, (+/-)

0.4%

  • Current, relative to output range, (+/-)

0.5%

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

  • Series mode interference (peak value of interference < rated value of input range), min.

40dB

40dB

  • Common mode interference (USS < 2.5 V) , min.

70dB

70dB

Interrupts/diagnostics/status information

Substitute values connectable

Yes; Parameterizable

Yes; Parameterizable

Integrated Functions

Control technology

  • Number of closed-loop controllers

16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection

16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection

Potential separation

Potential separation controller

  • between the channels

No

No

  • between the channels and backplane bus

Yes; Optocoupler

Yes; Optocoupler

Permissible potential difference

Between the inputs and MANA (UCM)

2.5 V DC

2.5 V DC

between M internally and the inputs

75 V DC/60 V AC

75 V DC/60 V AC

Isolation

Isolation tested with

500 V DC

500 V DC

Connection method

required front connector

2x 48-pin

2x 48-pin

Dimensions

Width

50mm

50mm

Height

290mm

290mm

Depth

210mm

210mm

Weights

Weight, approx.

1400g

1400g