Overview of technical specifications
This table lists the most important technical data. For more information and details, see Catalog D 81.1· 2008 Part 0 "Introduction".
Type of motor |
SIMOTICS GP/SD 1LE1/1PC1 IEC Low-Voltage Motors |
---|---|
Connection types |
Star connection/delta connection |
Number of poles |
2, 4, 6, 8, pole-changing for constant and square-law load torque |
Frame sizes |
80 M ... 315 L |
Rated output |
0.55 ... 200 kW (1LE1 motor series)/0.3 ... 9 kW (1PC1 motor series) |
Frequencies |
50 Hz and 60 Hz |
Versions |
Self-ventilated 1LE1 energy-saving motors with:
Self-ventilated 1LE1 motors with increased output and:
Forced-air cooled 1LE1 motors without external fan and fan cover with:
Naturally cooled 1PC1 motors without external fan and fan cover with:
|
Marking |
IEC 60034-30 IE1, IE2, IE3: 2, 4 and 6-pole |
Rated speed (synchronous speed) |
750 ... 3000 rpm |
Rated torque |
9.9 ... 1546 Nm (1LE1 motor series)/on request – following calculation when an order is placed (1PC1 motor series) |
Insulation of the stator winding |
Temperature class 155 (F), used acc. to temperature class 130 (B) (also for motors with increased output) |
Degree of protection |
IP55 as standard |
Cooling |
|
Admissible coolant temperature and site altitude |
–20 ... +40 °C as standard, site altitude up to 1000 m above sea level. |
Standard voltages |
50 Hz: 230 V, 400 V, 500 V, 690 V |
Type of construction |
|
Paint finish |
Standard: Color RAL 7030 stone gray |
Vibration severity level |
Level A (normal – without special vibration requirements) See "Balance and vibration quantity" in Catalog D 81.1 · 2008 Part 0 "Introduction" |
Shaft extension |
Balance type: Half-key balancing as standard See "Balance and vibration quantity" in Catalog D 81.1 · 2008 Part 0 "Introduction". |
Sound pressure level according to DIN EN ISO 1680 (tolerance+3 dB) |
The sound pressure level is listed in the selection and ordering data for the required motor. |
Weights |
The weight is listed in the selection and ordering data for the required motor. |
Modular mounting concept |
Rotary pulse encoder, brake, separately driven fan or prepared for mountings |
Consistent series concept |
|
Options |
See "Supplements to order numbers and special versions" |
General note
All the data listed in the catalog is applicable for a 50 Hz line supply. With converter-fed operation, the reduction factors for constant torque and drives for fans, pumps and compressors must be observed. Noise values for motors operating with a converter at frequencies other than 50 Hz are available on request.
Mechanical limit speeds
When the motor is operated at its rated frequency, it is important to note that the maximum speeds are limited by the limits for the roller bearings, critical rotor speed and rigidity of the rotating parts.
Ventilation/noise generation (converter-fed operation)
The fan noise can increase at speeds that are higher than the rated speed of self-ventilated motors. To increase motor utilization at low speeds it is recommended that forced-ventilated motors are used.
Mechanical stress and grease lifetime (converter-fed operation)
High speeds that exceed the rated speed and the resulting increased vibrations alter the mechanical running smoothness and the bearings are subjected to increased mechanical stress. This reduces the grease lifetime and the bearing lifetime. More detailed information on request.