3RM1 motor starter:

Home page, see聽http://www.siemens.com/motorstarter/3RM1

3SK safety relays can be used to protect 3RM1 motor starters:

Home page, see聽http://www.siemens.com/safety-relays

Industry Mall, see聽http://www.siemens.com/product?3SK



3RM13 motor starter with reversing functionality, electronic overload protection and safety-related shutdown

SIRIUS 3RM1 motor starters are compact devices 22.5聽mm wide, combining a large number of functions in a single enclosure. They consist of combinations of relay contacts, power semiconductors (hybrid technology), and an electronic overload relay for switching induction motors up to 3聽kW (at 400聽V) and resistive loads up to 10聽A (at AC voltages to 500聽V) under normal operating conditions.

The 3RM1 motor starters with overload protection with wide setting聽range are offered as direct-on-line starters and reversing starters and as versions with safety-related shutdown up to SIL聽3/PL聽e.

Seamlessly integrated safety right through to the main circuit

Problem-free integration of functional safety into the main circuit through the simple combination of 3RM1 and 3SK devices

Functional safety in the main circuit needs to be both simple and flexible.

The unique compatibility of hybrid 3RM1 fail-safe motor starters and 3SK safety relays means that integrated functional safety right through to the main circuit is no longer a problem.

Their compact design allows the motor starters to be installed to the right of the safety relay in a simple manner, just like an output expansion. The wiring of the safety-related signals to the relay can be performed simply, quickly and in an error-free manner using the device connector.

The ergonomically designed enclosure with removable terminals and terminal labeling in the hinged cover allows for the cables to be conveniently diagonally mounted from the front. Either screw-type or spring-loaded terminals with push-in technology are available.

Highlights

  • Fail-safe disconnection of motors up to 3聽kW
  • Problem-free combination of fail-safe motor starters and safety relays
  • End-to-end system, simple setup using device connectors
  • Ergonomic enclosure
Online Configurator:
  • Create individual motor starters or a complex motor starter group
  • Individual selection options, such as direct or reversing starting, spring-type or screw terminals, as well as motor current and control voltage
  • Graphic representation of the design during configuration
  • Automatic calculation of the matching motor starter protector/circuit breaker (for group configuration)

Link:聽http://www.siemens.com/sirius/configurators

Article No. scheme

Product versions

聽

Article number

聽

Product function

Direct-on-line starter

3RM10

0

鉂�

-

鉂�

AA

鉂�

4

聽

Failsafe direct starter

3RM11

0

鉂�

聽

鉂�

AA

鉂�

4

with ATEX certification and safety-related shutdown

Reversing starter

3RM12

0

鉂�

聽

鉂�

AA

鉂�

4

聽

Failsafe reversing starter

3RM13

0

鉂�

聽

鉂�

AA

鉂�

4

with ATEX certification and safety-related shutdown

Wide setting range for electronic overload release

0.1聽...聽0.5聽A

聽聽

1

聽聽聽聽聽

for motor standard output 0聽...聽0.12聽kW2)

0.4聽...聽2.0聽A

聽聽

2

聽聽聽聽聽

for motor standard output 0.09聽...聽0.75聽kW2)

1.6聽...聽7.0聽A (10聽A)1)

聽聽

7

聽聽聽聽聽

for motor standard output 0.55聽...聽3聽kW2)

Connection method

Screw terminals

聽聽聽聽

1

聽聽聽聽

Spring-type terminals (push-in)

聽聽聽聽

2

聽聽聽聽

Mixed connection method:

聽聽聽聽

3

聽聽聽

Screw terminals for main circuit, spring-type terminals (push-in) for control circuit

Rated control supply voltage Us

24聽V聽DC

聽聽聽聽聽聽

0

聽聽

110聽...聽230聽V聽AC, 110聽V聽DC

聽聽聽聽聽聽

1

聽聽

Example

聽

3RM13

0

1

-

2

AA

0

4

聽


1) Operation of resistive loads with maximum 10聽A

2) Standard three-phase motor, basis 4-pole at 400聽V聽AC, the actual startup characteristics of the motor as well as its rated data are important factors here.

Note:

The Article No. scheme shows an overview of product versions for better understanding of the logic behind the article numbers.

For your orders please use the article numbers quoted in the selection and ordering data.


















  © 挝� "咽 萃判梦" 2007-2022
  (4872) 700-366  skenergo@mail.ru
唔溴犟.体蝠桕�