6ES7972-0BB52-0XA0

Öåíà íà ñàéòå óêàçàíà ðîçíè÷íàÿ â ÅÂÐÎ áåç ó÷åòà ÍÄÑ.
Äëÿ óòî÷íåíèÿ öåíû è ðàçìåðà ïðåäîñòàâëÿåìîé ñêèäêè - çâîíèòå èëè ïðèñûëàéòå çàÿâêè

Çàêàçíîé íîìåðÂåñPGÎïèñàíèå ïðîäóêòàÖåíà
6ES7972-0BB52-0XA00.04250SIMATIC DP, ØÈÍÍÛÉ ÑÎÅÄÈÍÈÒÅËÜ ÄËß ÏÎÄÊËÞ×ÅÍÈß Ê ÑÅÒßÌ PROFIBUS ÄÎ 12 ÌÁÈÒ/Ñ, ÎÒÂÎÄ ÊÀÁÅËß ÏÎÄ ÓÃËÎÌ 90 ÃÐÀÄÓÑÎÂ, 15,8 X 59 X 35,6 MM (ØXÂXÃ), IPCD, ÒÅÕÍÎËÎÃÈß FAST CONNECT, Ñ ÐÀÇÚ¨ÌÎÌ ÄËß ÏÎÄÊËÞ×ÅÍÈß ÏÐÎÃÐÀÌÌÀÒÎÐÀÏî çàïðîñó



The DP/AS-i F-Link is a compact, safety-related router between PROFIBUS (DP slave) and AS-Interface, with the following features:

  • Monitoring the inputs of safety-related digital AS-i slaves (ASIsafe slaves) and forwarding of data through PROFIsafe. No additional safety-related components required for the AS-Interface (e.g. MSS ASIsafe Modular Safety System)
  • Can be used up to PL e according to EN ISO 13849‑1 and to SIL 3 according to IEC 61508/EN 62061.
  • As many as 62 AS-Interface slaves can be connected
  • Supports all AS-Interface master functions in accordance with the AS-Interface specification V3.0
  • Typically easy transmission of non-safety-related input/output data of all AS-i slaves
  • Integrated analog value transmission
  • Direct integration in PROFIBUS networks.
  • Local diagnostics using LEDs and display with control keys
  • Sturdy and narrow plastic enclosure in degree of protection IP20 for mounting on a standard mounting rail or wall mounting (with an adapter)
  • Fast device replacement in the event of a fault

Note:

A powerful, safety-related router between PROFIBUS (or PROFINET) and AS‑Interface can be set up as an alternative to the DP/AS‑i F‑Link by combining the CM AS‑i Master ST and F‑CM AS‑i Safety ST modules in a single ET 200SP station; see "Master" → "Master for SIMATIC ET 200" → "F‑CM AS‑i Safety ST for SIMATIC ET 200SP".

Functionality

Communication principle

The PROFIBUS DP master or the safe control communicates with the AS-Interface slaves over the DP/AS-i F-Link. The AS-Interface process data are mapped in different data areas for non-safety-related input and output data and safety-related input data.

Diagnostics

Extensive diagnostics is possible using the four LEDs, display and control keys or SIMATIC S7. Further details can be found in the manual, see “Additional Information�.

Configuration

The DP/AS-i F-Link is configured as follows:

  • With STEP 7 version V5.4 SP1 and higher: In particular, Siemens AS-Interface slaves can be conveniently configured via the slave selection dialog.
  • Uploading the ACTUAL configuration of an already configured AS-Interface network in a STEP 7 project is also possible.
  • The DP/AS‑i F-Link does not support AS‑i safety output modules.
  • The DP/AS‑i F-Link cannot be configured with TIA Portal.

Programming

In contrast to the MSS ASIsafe Modular Safety System, the DP/AS-i F-Link is a pure gateway, which does not run through its own safety logic. Programming of the safety function is implemented at the level of the higher-level fail-safe PLC, e.g.:

  • With Distributed Safety, version V5.4 SP1 or higher for SIMATIC S7-300F/416F
  • With SINUMERIK Safety Integrated

The safety and standard range can access the digital and analog I/O data of the connected AS-Interface slaves directly through the I/O address area of the CPU.

Operating conditions:

  • In the case of an AS‑i communication error (e.g. failure of an AS‑i standard slave or ASIsafe slave), the DP/AS‑i F‑Link sends the substitute value "0" to the F controller for all safe inputs.
  • No safe AS‑i outputs can be operated on the AS‑i line of the DP/AS‑i F‑Link.
  • Safe control of actuators is handled by the F controller, e.g. via safe SIMATIC output modules.
  • The DP/AS‑i F‑Link is not suitable for AS‑i Power24V.